SELF-ACTING MOVEMENT DETECTOR 

STYLE: “TMR TL-100” 

 

We are delighted that you have purchased this PIR detector. Please read these instructions before installation and retain for future 
reference. 

 
POSITIONING THE UNIT

 

When selecting the mounting position take into account the following points. 
1.The sensor is designed for optimum performance when mounted 2.5 meters above ground level. 
2.Avoid positioning close to trees or shrubs, which may cause false triggering during wet windy weather. 
3.Avoid pointing at or positioning close to heat sources such as flu's or heat extraction units, 

which may cause false triggering. 

4.Avoid pointing at bright lights as unit will not function when you set LUX control level to dark. 
5. Avoid mounting at strong electromagnetic disturbance, which may cause false triggering. 
6.The sensor is most sensitive to movement across the detection area as opposed to directly towards or away from the unit .Position the 

unit to point across flow areas.            

 
 
FITTING THE UNIT (see diagram.1)

 

Before commencing any electrical work, ensure mains supply cables are isolated by switching off and removing the relevant fuse. 
1 . Unscrew the screws 

ķ

, remove the back plate and terminal block. 

2 . Fitting the back plate on the fitting surface with screw 

ĸ

  ( supplied ). 

3 . Connecting the main power wires and loading wires to the terminal block ( see the relative symbols ), the wires must pass through the 

rubber gasket. 

4 . Re-fit the terminal block and screws 

ķ

 

 
 
 
                                   
 
 
 
 
 
 
 
 
 
                                                                                                                                                                                          lll 
                                                                                                                                                                                       
                                                                                                                                                                                   
                                                                                                                                                                                                                                                 
                                                                                                                Brown (Power cable)        L

Ę

                                          Brown (PIR) 

                                                                                                                Blue (Power cable)            N                                                   
                                                                                                                Blue (Load cable)                                 Blue (PIR)                
                                                                                                              Brown (Load cable)      L

Ę

                                         

                                                                                                    Yellow/Green (Power cable)                             Red (PIR) 

      Yellow/Green (Load cable) 

 

Diagram. 1 

 

 

After finishing the fitting operation you can adjust the detection area and working state of PIR sensor

 
OPERATION MODE AND ADJUSTING (see diagram. 2 ) 

1 .When power on, the PIR detector enter into the “WARN-UP” periods (abort 40 seconds) , and then the PIR detector will change to the 

AUTO MODE automatically. During the AUTO MODE. You can easy to carry out the Walk-Testing. 

  WALK-TESTING

: Before walk-testing, please put the LUX KNOB and TIME KNOB to the “Walk-testing position”, Once the PIR sensor 

receives a valid trigger signal ( such as movement human body ) within its detection area, the load ( such as lamp ) will be turned on for 
a duration time, You will obtain the desired detection area by walking slowly.

 

2. Turn off the override switch for more than 3 minutes and then turn on again, the PIR detector will begin a new process for 
“AUTO MODE”. 
 

Summary of Contents for TMR TL-100

Page 1: ...are i cavi della corrente alla morsettiera come da diagramma 1 è opportuno che i cavi passino attraverso la guaina in gomma 4 Ripristinare la morsettiera sulla piastra posteriore e fissare il sensore che le apposite viti Finita l operazione di fissaggio dell apparato si può aggiustare l area di rivelazione muovendo in senso verticale il sensore dopodiché settare il timer e il luxmetro come segue S...

Page 2: ...d utilizzo del prodotto ART 28 10000 PAGINA 2 DI 4 DETTAGLI TECNICI Voltaggio 220 240VAC 50 60Hz Portata Massima 500W 1000W lampadina incandescente Angolo di rivelamento Max 180 120 Durata temporizzatore regolabile da 5 20 secondi a 6 8 minuti Livello Luxmetro 10 LUX a 150 LUX regolabile IMPORTANTE non tentare di togliere la lente in quanto è molto facile danneggiare il sensore e rende nulla la ga...

Page 3: ... directly towards or away from the unit Position the unit to point across flow areas FITTING THE UNIT see diagram 1 Before commencing any electrical work ensure mains supply cables are isolated by switching off and removing the relevant fuse 1 Unscrew the screws ķ remove the back plate and terminal block 2 Fitting the back plate on the fitting surface with screw ĸ supplied 3 Connecting the main po...

Page 4: ...re should need 5 sec to wait for the stability of photocell CDS when you adjust the LUX knob from daylight to darkness or opposite ADJUSTING THE DURATION TIME The length of time that remains switched on after activation can be adjusted from 5 20 sec to 6 8 min Rotating the TIME knob clockwise to reduce the duration time Note Once the load has been triggered by the PIR detector any subsequent detec...

Reviews: