34
Big One Xtreme II_1.0_ENG.docx
Elaut NV
OVERVIEW EVENTS
ERROR CODES
1.1.
Common Events
Wrong Os version
200
The software needs to be reinstalled.
Missing PF config
201
Contact Elaut NV.
EIC Communication bus Error
203
The EIC communication bus could not be initialized.
1.2.
Game Payout Events
Over Payout Error
210
Check the claw settings.
Under Payout Error
220
Check the claw settings.
1.3.
Playfield Events
Consolation Error
4
The consolation prize couldn’t be paid out in time.
Bill acceptor (pulse) Error
5
Check if the Bill
Acceptor isn’t blocked.
Win detector blocked
706
The prize detector is stuck closed, check if nothing is
blocking the optical sensors.
HDMI disconnected Error
10
Check if the TV is ON and all cables are connected, also
select the correct HDMI input on your TV screen.
1.4.
Control Panel Events
GIO Control Panel no communication
1200
There’s no communication with the G
eneral IO control
panel PCB.
GIO Control Panel firmware Error
1210
Please power off the machine - Contact Elaut NV.
1.5.
Prize Box Events
GIO Prize Box no communication
1250
No communication with the General IO Prize Box PCB.
GIO Prize Box motor stalled
1260
Problem prize box. Check the connections and
functionality. Change parts if needed.
GIO Prize Box overcurrent
1261
Problem prize box. Check the connections and
functionality. Change parts if needed.
GIO Prize Box switch Error
1262
Problem prize box. Check the connections and
functionality. Change parts if needed.
GIO Prize Box calibration time out
1266
Problem prize box. Check the connections and
functionality.
GIO Prize Box calibration Error
1267
Problem prize box. Check the connections and
functionality.
GIO Prize Box firmware Error
1268
Please POWER OFF the machine - Contact Elaut NV.
GIO Prize Box blocked
1269
Problem prize box. Check the connections and
functionality.
GIO Prize Box win detector jitter detected.
1270
Problem prize box. Check the connections and
functionality.
1.6.
Counter Events
Mech counter no communication
1300
No communication with the EIC 8 MD PCB.
Mech counter not connected
1302
Check the connections of the mechanical counters.
Replace if needed.
Mech counter firmware Error
1305
Please POWER OFF the machine - Contact Elaut NV.
1.7.
Gantry Events
X motor calibration Error
1500
The calibration of the X motor could not be completed.
No communication with X motor
1501
There’s no communication with the
EIC BOX PCB.