Page 1: ...VOLT Q5E SIX PACK user manual E L A TI ON VOLT Q5E SIX PACK user manual...

Page 2: ...affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use...

Page 3: ...arranty 7 Safety Instructions 8 General Guidelines 9 Fixture Overview 10 Battery Charging 11 Fixture Installation 12 Understanding DMX 15 Fixture Menu 18 Internal Wireless DMX Receiver Set Up 26 DMX C...

Page 4: ...otection The first digit Foreign Bodies Protection indicates the extent of protection against particles entering the fixture and the second digit Water Protection indicates the extent of protection ag...

Page 5: ...listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS 1 VOLT Q5 Charging Road Case powerCON Cable 6 VOLT Q5E Fixtures 6 9 8 ft 3m 3pin IP Fe...

Page 6: ...ng container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without a R A number clearly marked on the outside of the package will be refused an...

Page 7: ...r by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this war...

Page 8: ...proper operation follow the Installation guidelines described in this manual Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts bra...

Page 9: ...ithout knowledge how to do so DO NOT allow operation by persons who are not qualified to operate this type of fixture Most damages are the result of operations by nonprofessionals Consistent operation...

Page 10: ...al ver 2 F I X T U R E O V E R V I E W 1 LED Lens 2 LCD Menu Display 3 MODE ESC Button 4 UP Button 5 DOWN Button 6 ENTER Button 7 Charge Indicator 8 Wireless DMX Indicator 9 Power Switch 10 Power IN 1...

Page 11: ...ng on fixture usage and settings install location temperature and number of charge cycles CHARGE TIME Units must be placed in charging road case for a period of 8 hours to fully charge the batteries R...

Page 12: ...tion mount the fixture in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture Ambient operating temperature range for this fixture is 14 113 F 10...

Page 13: ...ed omega brackets using a M10 screw fitted through the center hole of the Omega Bracket Be sure to attach the included Safety Cable to the fixture using the safety cable rigging point integrated in th...

Page 14: ...ic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture is...

Page 15: ...ixture to fixture via data IN and data OUT XLR terminals located on the fixtures most controllers will only have output jacks DMX LINKING To ensure proper DMX data transmission always use the VOLT ser...

Page 16: ...must be used Always be sure daisy chain your in and out data connections never split or Y your DMX connections Address 1 Address 10 Address 19 DMX 512 CONNECTION WITH DMX TERMINATOR A DMX terminator s...

Page 17: ...ch unit will start to listen to the channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect...

Page 18: ...ton once will access the fixture s main menu Once in the main menu you can navigate through the different functions and access the sub menus with the UP and DOWN buttons Once you reach a field that re...

Page 19: ...ry Charge Level Soft Ver V1 1 0 Software Version Persnal Stat Set Addr DMX ON OFF Address Via DMX NoDMXSta CloShut Hold Auto Auto Run If No DMX Disp Set Off Time 02 59m 05m Display Shut Off Time Key L...

Page 20: ...nder EditProg and edit individual scenes under EditScen Info TimeInfo Cur Time Displays fixture run time from last power ON The counter is reset after each time the fixture is powered OFF TotalHrs Dis...

Page 21: ...t Channel 1 to a value of 7 set Channel 2 to a value of 7 and then set Channel 3 to a value of 57 Example 2 If the desired DMX address is 420 set Channel 1 to a value of 7 set Channel 2 to a value of...

Page 22: ...e light on a flat surface wall and perform fine adjustments Mode Set UserMode Select operating mode which includes DMX Channel and User defined modes EditProg Sel Prog Select one of the 10 user define...

Page 23: ...the Slave unit was assigned to If e g a Slave unit is set to Slave 1 in the menu SetSlave the Master unit sends Prog 1 to the Slave unit If set to Slave 2 the Slave unit receives Prog 2 To start an Au...

Page 24: ...the same program as the master units Press ENTER to confirm Press MODE ESC in order to return to the main menu 4 Program Selection for Edit Program Select EditProg Press ENTER to confirm Select the d...

Page 25: ...Working With Built In Program continued Example Prog 2 includes scenes 10 11 12 13 Prog 4 includes scenes 8 9 10 Prog 6 includes scenes 12 13 14 15 ProPart1 is Prog 2 ProPart2 is Prog 3 ProPart3 is Pr...

Page 26: ...onnect a fixture to a controller via a DMX cable when the EWDMX system is in use This could cause serious damage to the controller SETTING UP THE EWDMX SYSTEM Follow the instructions included with the...

Page 27: ...Transmitter First be sure the fixture s is powered ON and then hold down the configuration button on the WDMX Transmitter for as least 5 seconds This will automatically clear the link between the EWDM...

Page 28: ...0K 6 6 COLOR MACROS 0 NO Function 1 7 Color Macro 1 8 15 Color Macro 2 16 23 Color Macro 3 24 31 Color Macro 4 32 39 Color Macro 5 40 47 Color Macro 6 48 55 Color Macro 7 56 63 Color Macro 8 64 71 Col...

Page 29: ...BE 0 31 LEDs OFF 32 63 LEDs ON NO STROBE 64 95 STROBE Effect SLOW to FAST 96 127 LEDs ON NO STROBE 128 159 STROBE Pulse Effect In Sequences 160 191 LEDs ON NO STROBE 192 223 Random STROBE Effect SLOW...

Page 30: ...authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detail...

Page 31: ...lter Gel Frame Electronic Strobe and Dimming Variable Dimming Curves Multiple Color and Chase Macros CONTROL CONNECTIONS 4 DMX Channel Modes 4 5 11 12 Internal Wireless EWDMX Receiver 4 Button Control...

Page 32: ...Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice VOLT Q5E DIMENSIONAL DRAWINGS Please Note Specifications and improveme...

Page 33: ...vy Duty Wrap Around Hook Style Clamp EWD001 EWDMX IP Wireless IP65 DMX Transceiver VOLT5CHARGER VOLT Q5E 26 2 VDC Charger IEC Power Cable VOLT 3MDLC VOLT Series 9 8 ft 3m 3pin Male IP to 3pin Female I...

Page 34: ......