Power Supply:

 The Elation Professional

®

 TVL1000 II contains an 

electronic ballast, which will auto sense the voltage when it is plugged 

into the power source. With the electronic ballast you do not need to 

worry about wall voltage, this unit can be plugged in anywhere.  Also 

be sure to only use the included I.E.C. power cable supplied with the 

unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A  DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-

gle controller, as long as all fixtures and the controller are DMX com-

pliant. To ensure proper DMX data transmission, when using several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The TVL1000 II 3 DMX channel modes. The DMX address 

is set electronically using the controls on the side of the unit. Your unit 

and your DMX controller require a approved DMX-

512 110 Ohm Data cable for data input and data 

output. We recommend Accu-Cable DMX cables. 

If you are making your own cables, be sure to use 

standard 110-120 Ohm shielded cable (This cable 

may be purchased at almost all professional sound 

and lighting stores). Your cables should be made 

with a male and female XLR connector on either 

end of the cable. Also remember that DMX cable 

must be daisy chained and cannot be split.

 TVL1000 II   

                                                     Set Up

Figure 1

©Elation Pr

o

fessional®  -  www.elationlighting.com  - TVL1000 II Instruction Manual Page 6

 TVL1000 II   

 

 

                                 Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Summary of Contents for TVL1000-II

Page 1: ...has 3 DMX Modes Two 2 Channel Modes and a 3 Chan nel Mode The fixture has two operating modes manual mode or DMX controlled The TVL1000 II can only be run as stand alone unit This unit is suitable fo...

Page 2: ...Install Or Operate This Unit To reduce the risk of electrical shock or fire do not expose this unit rain or moisture Do not spill water or other liquids into or on to your unit Be sure that the local...

Page 3: ...end Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cab...

Page 4: ...ed by a professional and it must be installed in a place where it is out of the reach of people s grasp TVL1000 II Installation Elation Professional www elationlighting com TVL1000 II Instruction Manu...

Page 5: ...e change into the system memory If the MENU button is not pressed and held within eight seconds the fixture will automatically confirm and lock the change into the system memory To exit without making...

Page 6: ...in when power is applied or the DMX signal is lost MASL Master Slave If the DMX signal is lost or power is applied the unit will automatically go into Master Slave mode BLND Blackout If the DMX signa...

Page 7: ...3 You can also use the Color Adjust Knob and Dimmer Knob to manually create your desired color temperature Please see the Control Panel on page 8 TVL1000 II Universal DMX Control Elation Professional...

Page 8: ...s you will need to use a new power outlet They must be the same fixtures DO NOT mix fixtures NOTE Powered via battery does not mean that 5 fixtures are being powered by one battyer each unit must have...

Page 9: ...re Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output Cleaning frequency depends on the...

Page 10: ...als under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professionals All products covered by this warranty were...

Page 11: ...disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any informat...

Page 12: ...68 EW Kerkrade The Netherlands service americandj eu www americandj eu Tel 31 45 546 85 00 Fax 31 45 546 85 99 Elation Professional A Division of the AmericanDJ Group of Companies World Headquarters 6...

Reviews: