FIXTURE INSTALLATION
10
FLAMMABLE MATERIAL WARNING
Keep fixture at least 5.0 ft (1.5m) away from any flammable materials, decoration,
pyrotechnics, etc.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or installa-
tions.
ADDITIONAL PRECAUTIONS:
• For added protection, mount the fixture outside of walking paths, seating areas, or areas were
unauthorized personnel might reach the fixture.
• Ambient operating temperature range for this fixture is 5°F to 113°F (-15°C to 45°C). Do not
operate the fixture when ambient temperatures fall outside of this range.
• Before mounting the fixture to any surface, make sure the installation area can hold a minimum
point load of 10 times the weight of the fixture.
• Fixture installation must always be secured with a secondary safety attachment, such as an
appropriately rated safety cable.
• Never stand directly below the device when mounting, removing, or servicing.
POWER LINKING
Max number of units that can be power linked is as follows:
• 6 units @110V.
• 15 units @240V.
CLAMP MOUNTING
The SIXBAR 1000™ includes integrated dual floor stand/rigging yokes. When mounting this fixture to
a truss, be sure to secure appropriately rated clamps to the yokes using a M10 screw fitted through
the center hole.
SAFETY CABLE
Always use a safety cable (not included) whenever installing this fixture in a suspend-
ed environment to ensure that the fixture will not drop if the clamp fails.