Special Note: Line Termination.

  

When longer runs of cable are used, you may need to use a termina-
tor on the last unit to avoid erratic behavior. A terminator is a 90-120 
ohm 1/4 watt resistor which is connected between pins 2 and 3 of a 
male XLR connector (DATA + and DATA -). This unit is inserted in the 
female XLR connector of the last unit in your daisy chain to terminate 
the  line.    Using  a  cable  terminator  will  decrease  the  possibilities  of 
erratic behavior. 

 Pro Haze DMX™                                    Set Up cont.

Figure 2

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 3

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Linking:

The Pro Haze DMX™ is a DMX intelligent hazer and must follow stan-
dard  DMX  protocol  when  used  in  DMX  mode.  A  DMX  signal  cannot 
be split  unless you are using an approved DMX splitter such as the 
LSC

®

 DMX Branch 4.

 Link your hazers together using standard DMX 

cables as described on page 7 of this manual. Be sure that each fixture 
follows an “IN”/”OUT” pattern starting from your DMX controller. Your 
controller will always be the first output in a DMX chain. Link all your 
DMX devices together regardless of their brand or type.  To control all 
the hazers at once, set all the hazers to the same DMX address.

 Pro Haze DMX™                                      Haze Fluid

Hazer Liquid:

Only use Elation

®

 brand haze juice. Elation

®

 juice is specially formu-

lated to be used in this machine, other brand fluids may be made out 
of chemicals that may clog your haze machine. Using haze juice other 
than Elation

®

 brand will void your manufactures warranty. Do not allow 

the hazer liquid to become contaminated. Always replace the caps on 
the hazer liquid container and the hazer’s liquid tank immediately after 
filling.

©

Elation Professional

®

 - www.elationlighting.com - Pro Haze DMX™ Instruction Manual Page 9

©

Elation Professional

®

 - www.elationlighting.com - Pro Haze DMX™ Instruction Manual Page 10

Universal DMX Control: 

This function allows you to use a univer-

sal  DMX-512  controller  such  as  the  LSC

®

  DMX  Operator™  or  Show 

Designer to control haze output. 
1.   The Pro Haze DMX™ uses one DMX channel. Channel value 0  
 

to 5 will not produce haze output, channel value 6 to 255 the 

 

Pro Haze DMX will produce haze.

3.  To control your fixture in DMX mode, follow the set-up procedures  
 

on pages 8 - 9 as well as the set-up specifications that are includ- 

 

ed with your DMX controller. 

4.  Use the controller’s faders to control the DMX fixture trait.
5.  For longer cable runs (more than a 100 feet) use a terminator on  
 

the last fixture.

6.  For help operating in DMX mode consult the manual included  
 

with your DMX controller.

Remote Operation:

Place your haze machine in a well ventilated area. Be sure your hazer 
is placed on a flat, level surface. Be sure your hazer remote has been 
plugged  in  securely.  Always  maintain  an  adequate  supply  of  Elation 
Haze Juice™ in the fluid reservoir. Running the haze machine dry will 
cause pump failure and or clogging. Running a haze machine dry is 
the largest cause of haze machine failure. Only Elation Haze Juice™ 
is  recommended  and  not  all  haze  juice  is  created  equal.  Plug  your 
haze machine into a standard 110V/120V supply. Once the machine is 
plugged in and turned on, the power switch will begin to glow indicat-
ing the unit is receiving power.

 Pro Haze DMX™                   Operating Instructions

Summary of Contents for PRO HAZE DMX

Page 1: ...n should you encounter problems during your set up or ini tial operation You may also visit us on the web at www elationlighting com for any comments or suggestions Service Hours are Monday through Friday 9 00 a m to 6 00 p m Pacific Standard Time Voice 323 582 3322 Fax 323 582 3108 E mail support elationlighting com Warning To prevent or reduce the risk of electrical shock or fire do not expose thi...

Page 2: ... may cause the unit to clog This unit is designed for interior use only Do not use this unit outdoors Be sure that the local power outlet match that or the required voltage for your haze machine Do not attempt to operate this unit if the power cord has been frayed or broken Please route your power cord out of the way of foot traffic Do not attempt to remove or break off the ground prong from the el...

Page 3: ...aze DMX Warranty The PRO HAZE DMX hazer carries a one year limited warranty We recommend you fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a R A Number If the unit is under warranty you must provide a proof of purchase invoice Pro Haze DMX Set Up Before beginning initial setup of your El...

Page 4: ...h 4 address equals 8 Dip Switch 5 address equals 16 Dip Switch 6 address equals 32 Dip Switch 7 address equals 64 Dip Switch 8 address equals 128 Dip Switch 9 address equals 256 Figure 1 Each dip switch has a preset value A specific DMX address is set by combining the dip switches that sum your desired value For exam ple To achieve a DMX address of 21 combine dip switches 1 3 and 5 Sense dip switc...

Page 5: ...trol all the hazers at once set all the hazers to the same DMX address Pro Haze DMX Haze Fluid Hazer Liquid Only use Elation brand haze juice Elation juice is specially formu lated to be used in this machine other brand fluids may be made out of chemicals that may clog your haze machine Using haze juice other than Elation brand will void your manufactures warranty Do not allow the hazer liquid to b...

Page 6: ...g Instructions cont Remote Control The haze machine comes with a full function remote control The remote control is connected to the rear of the unit Be sure to connect the remote to the proper jack Do not try to force the remote con nection in to the jack You could damage your remote The remote has three LED s that will indicate the different functions See the next page remote functions and descr...

Page 7: ...only to a designated point within the United States If the entire instrument is sent it must be shipped in its original package No accessories should be shipped with the product If any accessories are shipped with the product Elation Professional shall have no liability whatsoever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial nu...

Page 8: ... Oil Based Elation Haze Juice AIR COMPRESSOR 270w DUTY CYCLE Not to exceed 6 hours turned on Pro Haze DMX Specifications Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Elation Professional A Division of the AmericanDJ Group of Companies World Headquarters 4295 Charter Street Los Angeles CA 90058 USA Tel 3...

Reviews: