LAMP INSTALLATION PROCEDURE - [continued]
9.
Be sure to reset the
LAMP HOURS
in the system menu to prevent the protection
circuitry from accidently shutting off the lamp during normal operation.
10.
If the lamp protection circuitry has already been initiated and the
LAMP HOURS
is
not reset, the
“Replace the Lamp”
warning will continue to flash and fixture will
eventually shut down. To reset
LAMP HOURS
, see instructions below.
LAMP HOURS RESET PROCEDURE
1.
Activate the main menu by pressing
MODE/ESC
and toggle to
“Information”
.
2.
Press
ENTER
and press
UP
or
DOWN
to toggle to
“Time Information”
.
3.
Press
UP
or
DOWN
to toggle to
“LampTime Password”
and press
ENTER
. Then press
UP
or
DOWN
to enter the reset pass code,
“038”
and press
ENTER
to confirm. The
display will automatically revert to
“LampTime Password”
, next press
UP
or
DOWN
to toggle down to
“Clean Lamp Time”
.
4.
Press
ENTER
and select
“ON”
. The lamp timer has now been reset, press
MODE/ESC
to exit the menu and return to the home screen.
LAMP OPTIMIZATION
Unlike traditional discharge lamps the
Phillips
™
Platinum 17 RA Lamp
does
NOT
require optimization. The lamp orientation and optimization procedure has been
preset during the manufacturing process of the lamp.
Please remember the
Phillips
™
Platinum 17 RA Lamp
is
NOT
a hot-restrike lamp
therefore, you must wait approximately
15 minutes
before you can attempt to
restrike the lamp once it has been turned off.