18
M A N U A L D I M M I N G A N D Z O O M C O N T R O L
FEATURE IS DISABLED WHEN DMX INPUT CABLE IS CONNECTED TO FIXTURE!
TO USE DIMMING AND ZOOM KNOBS, DISCONNECT DMX CABLE IF CONNECTED.
Follow steps below to enable manual DIMMING and ZOOM control knobs.
1. Access fixture system menu navigating to
Test
menu then access
ManCtrl
sub menu.
MAIN MENU SUB MENU OPTIONS / VALUES
(Default Settings in
BOLD
)
DESCRIPTION
Test
Reset.M
Zoom
Reset Zoom Motor
ManCtrl
Dimmer, Zoom,
Strobe
Manual Control Functions
Calibrat
PassWord
Password=
050
Calibrate Zoom Motor
(PSWD Required to Access)
Zoom
000-255
NOTE
: To access the LCD Menu Control Display when locked/OFF, press and hold the
MODE
button for 3 seconds.
2. Select
Stobe
menu, set to value of
255 (LED ON)
, then exit fixture system menu.
3. Push
DIMMING
knob to unlock, rotate to desired level, push knob again to lock.
Repeat this process each time a dimmer adjustment is desired.
4. Push
ZOOM
knob to unlock, rotate to desired level, push knob in again to lock.
Repeat this process each time a dimmer adjustment is desired.
LCD DISPLAY
DMX CABLE CONNECTED
NO DMX CABLE CONNECTED
Summary of Contents for KL FRESNEL 8