background image

2

©2022 ELATION PROFESSIONAL

 all rights reserved. Information, specifications, diagrams, 

images, and instructions herein are subject to change without notice. ELATION PROFES-

SIONAL logo and identifying product names and numbers herein are trademarks of ELATION 

PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable 

materials and information now allowed by statutory or judicial law or hereinafter granted.  

Product names used in this document may be trademarks or registered trademarks of their 

respective companies and are hereby acknowledged.  All non-ELATION brands and product 

names are trademarks or registered trademarks of their respective companies. 

ELATION PROFESSIONAL

 and all affiliated companies hereby disclaim any and all liabilities 

for property, equipment, building, and electrical damages, injuries to any persons, and direct 

or indirect economic loss associated with the use or reliance of any information contained 

within this document, and/or as a result of the improper, unsafe, insufficient and negligent 

assembly, installation, rigging, and operation of this product. 

Elation Professional USA |

 6122 S. Eastern Ave. | Los Angeles, CA. 90040 

323-582-3322 | 323-832-9142 fax | 

www.elationlighting.com | [email protected]

Elation Professional B.V. |

 Junostraat 2 | 6468 EW Kerkrade, The Netherlands

+31 45 546 85 66 | +31 45 546 85 96 fax | 

www.elationlighting.eu | [email protected]

 

Elation Professional Mexico

AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000

+52 (728) 282-7070

Date

Document 

Version

Software 

Version

DMX Channels

Notes

06/26/2020

1.0

1.03

1/2/3/4/5 ch.

Initial Release

10/26/2022

1.1

1.04

No change

Added RDM; updated 

Installation Instructions,  

System Menu, Encoder Knob, 

DMX Traits

DOCUMENT VERSION

Due to additional product features and/or enhancements, an updated version 

of this document may be available online. 

Please check 

www.elationlighting.com 

 for the latest revision/update of 

this manual before beginning installation and/or programming.

Summary of Contents for KL FRESNEL 6 CW

Page 1: ...User Manual KL FRESNEL 6 CW PO...

Page 2: ...ciated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of th...

Page 3: ...ns 6 Maintenance Guidelines 8 Overview 9 Installation Guidelines 11 Accessory Installation 15 Remote Device Management RDM 17 Control Panel 18 System Menu 19 Fan Control 21 Encoder Knob 22 DMX Traits...

Page 4: ...g customer support Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Rotating Barn Doors x1 Junior Pin x1 Gel Frame x1 Locking Power Cable x1 CUSTOME...

Page 5: ...t its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this war ranty sh...

Page 6: ...l instructions and guidelines in this manual Elation Profes sional is not responsible for injuries and or damages resulting from the misuse of this fixture due to the disregard of the information prin...

Page 7: ...and air inlets must remain clean and never blocked Leave approx 6 15cm between the fixture and other devices or a wall in order to allow for proper cooling When installing fixture in a suspended envi...

Page 8: ...service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed electrical chec...

Page 9: ...ting Yoke 3 Clamp Mounting Point 4 Junior Pin installed 5 Tilt Adjustment Knob 6 Pan Adjustment Knob 7 Dimmer Adjustment Knob 8 Enter Button 9 Display Screen 10 Down Button 11 Up Button 12 Mode Button...

Page 10: ...10 O V E R V I E W 15 Service Port 16 Fuse T3A 250V 17 Power In 18 Power Out 19 3 pin DMX In 20 5 pin DMX In 21 3 pin DMX Out 22 5 pin DMX Out...

Page 11: ...perate the fixture when the ambient temperature falls outside of this range Fixture s should be installed away from walking paths seating areas or areas were unauthor ized personnel might reach the fi...

Page 12: ...hen mounting this fixture to truss be sure to secure an appropri ately rated clamp not included to the clamp mounting point on the yoke and attach a sepa rate SAFETY CABLE of the appropriate rating no...

Page 13: ...of all installation material and the fixture among other skills If you lack these qualifications do not attempt the installa tion yourself Improper installation can result in bodily injury The fixture...

Page 14: ...s frost filters iris shutters motors belts wiring discharge lamps and LEDs This issue is not specific only to Elation lighting fixtures but rather it is a common issue with lighting fixtures from all...

Page 15: ...l frame which can be installed by following the steps shown below 1 Release the lock on the lens frame latch and flip the latch upward 2 Slide the gel frame into place in the slot in front of the fixt...

Page 16: ...lowing the steps shown below 1 Release the lock on the lens frame latch and flip the latch upward 2 Slide the barndoors into place in the slot in front of the fixture lens and gel frame 3 Flip the len...

Page 17: ...wed directly via the unit s display screen including the DMX Address DMX Channel Mode and Temperature Sensors FIXTURE RDM INFORMATION RDM Code Device ID Device Model ID Personality ID 22A6 0000 FFFF 1...

Page 18: ...nu From the main menu you can navigate through the different functions and access the sub menus with the UP and DOWN buttons Once you reach a field that requires adjusting press the ENTER button to ac...

Page 19: ...er 16bit 3CH Standard Extended FUNCTION Status Lost DMX Black Hold LCD Set Display On Off 30s screen saver setting Key Lock On Off Display menu button lock Flash On Off Display flashes when no signal...

Page 20: ...ry On Off Primary mode switch DFSE On Off Reset to default settings INFO Time Info Current Current run time hours Total Fixture total run time hours Last Run time since last cleared hours Clear On Off...

Page 21: ...duced when the LED engine cannot be cooled to its safe operating range due to a high ambient temperature NOTE This mode is recommended for daily operation High Fan speeds are increased throughout the...

Page 22: ...knob The dimming can then be adjusted by turning the knob To exit Manual Dimmer Mode use the dis play screen control buttons to navigate to User Mode in the main system menu and change the user mode...

Page 23: ...55 Dimmer Intensity 0 to 100 2 2 2 000 255 Dimmer Intensity Fine 2 3 3 Strobe 000 031 LED Off 032 063 LED On 064 095 Strobe Effect slow to fast 096 127 LED On 128 159 Pulse Effect slow to fast 160 191...

Page 24: ...5 Control hold for 3s 000 100 Idle Refresh Rate 101 105 900 Hz 106 110 1000 Hz 111 115 1100 Hz 116 120 1200 Hz default 121 125 1300 Hz 126 130 1400 Hz 131 135 1500 Hz 136 140 2500 Hz 141 145 4000 Hz...

Page 25: ...20 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 Stage 2 0 1100 0 1660 Rise Time ms Down Time ms Rise Time ms Down Time ms Rise Time Down Time Dimming Curve Ramp Effect 0 sec...

Page 26: ...ENTER again 6 Scroll to the Yes option and press ENTER 7 Scroll to the desired software file and press ENTER 8 Select On and press ENTER again The software should now begin copying Note Do NOT interr...

Page 27: ...m Electronic Dimmer and Strobe Variable 16 bit Dimming Modes and Curves COLOR 5 600K Cool White LED CONTROL CONNECTIONS Manual and DMX Controlled Dimmer and Shutter Dimmer and Zoom Rotary Dials 5 DMX...

Page 28: ...D I M E N S I O N A L D R AW I N G S FIXTURE WITH JUNIOR PIN INSTALLED 1 1in 20mm 5 6in 141 1mm 7 3in 186mm 10 9in 276 6mm 13 5in 344mm 9 8in 248mm 22 0in 558 2mm 9 8in 248mm 22 1in 561 2mm 13 5in 344...

Page 29: ...29 D I M E N S I O N A L D R AW I N G S BARN DOOR AND JUNIOR PIN INSTALLED 14 8in 375 5mm 22 0in 558 2mm 5 6in 141mm 1 3in 33mm...

Page 30: ...ch the unit runs a brief self evaluation If an internal problem is detected an error code will flash in the be displayed These codes are listed in the table below ERROR CODES Error codes are subject t...

Page 31: ...31...

Page 32: ......