ELATION© KL FRESNEL 4™ 

S Y S T E M    M E N U 

Features are subject to change without any prior written notice. 

Supports Software Versions: ≥ 1.02 

MAIN MENU 

SUB MENU 

OPTIONS / VALUES 

(Default Settings in BOLD)

 

DESCRIPTION 

Address 

Address 

001 ~ XXX 

Set DMX Address Setting 

UserMode 

User Mode 

1CH, 2CH, 3CH, 4CH 

Set DMX Channel / User Mode 

Function 

Status 

Lost Dmx 

Hold / Black 

Function If NO DMX Detected 

Display 

ON / OFF 

OLED Display Screen Saver Mode 

*When ON goes off after 30 seconds. 

ONLY WHEN DMX IS CONNECTED. 

LCD. Set 

Key Lock 

ON / OFF 

Control Front Panel Buttons Key Lock 

Flash 

ON / OFF 

Display flashes when NO DMX 

Invert 

OFF / ON 

Flip LCD Display 180º 

Temp. C/F 

F / C 

+7?B7D3FGD7*I;F5:7FI77@VV 

Dim Curve 

Standard, Stage, TV, Architec, Theatre 

Set Dimmer Curve Mode 

Disp. Set 

ADDR, Disp.CH, Salve 

Set Information to Display on LCD 

Fan. Set 

Led Fan 

Auto, High, Low 

Set LED Fan Speed 

Gamma 

2.0, 2.2, 2.4, 2.8 

Set Gamma Brightness 

Frequen 

900Hz, 1000Hz, 1100Hz, 1200Hz, 1300Hz, 

1400Hz, 1500Hz, 2500Hz, 4000Hz, 5000Hz, 

10Hz, 15Hz, 20Hz, 25Hz 

Set LED Refreash Frequency 

USB_Update 

OFF, ON 

Software Update Port - Contact 

Service 

DFSE 

OFF, ON 

Restore Factory Settings 

Info 

TimeInfo 

Current 

000 (Hours) 

Fixture Run Time From Power ON 

Total 

000 (Hours) 

Fixture Total Run Time 

Last 

000 (Hours) 

Clear Fixture Last Run Time 

Password 

PIN= 050 

Enter PIN to Access Clear Last. Menu 

Clear 

ON / OFF 

Reset Fixture Last Run Time 

TempInfo 

Led Temp 

000 F (C)   

Temperature of LED 

Err. Info 

Error Record 1 ~ Error Record 10 

Display 10 Recent Error Messages 

ModelInf 

KLF4 

Display Model Name 

Software 

Software 

V1.02 

Software Version 

(Greater than or Equal to) 

Test 

ManCtrl 

Dimmer, Strobe 

Test Functions 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for KL FRENSEL 4

Page 1: ...KL FRENSEL 4 user manual E L A TI ON KL FRESNEL 4 user manual...

Page 2: ...property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document a...

Page 3: ...N T S General Information 4 Warranty 6 Safety Instructions and Guidelines 7 Overview 9 Installation 10 System Menu 14 DMX Channel Functions And Values 17 Cleaning and Maintenance 18 Technical Specifi...

Page 4: ...operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your unit for damage and be sure all ac...

Page 5: ...ompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well as the R A number must also be written d...

Page 6: ...nal if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this warranty does not include...

Page 7: ...re and only the original rigging parts omega brackets included with this fixture should be used for installation Any modifications to the fixture and or the mounting hardware included will void the or...

Page 8: ...s no less than M10 x 25 mm and always install fixture with an appropriately rated safety cable Always disconnect fixture from main power source before performing any type of service and or cleaning pr...

Page 9: ...T I O N 1 powerCON TRUE1 Out 2 powerCON TRUE1 In 3 5pin DMX In 4 5pin DMX Out 5 USB Software Update Port 6 OLED Control Menu Display 7 MODE Button 8 UP Button 9 DOWN Button 10 ENTER Button 11 Manual...

Page 10: ...ace is properly certified to safely hold the combined weight of the fixture clamps cables and accessories Fixture ambient operating temperature range is 14 to 113 F 10 to 45 C Do not use the fixture u...

Page 11: ...e also has a top lock that secures these accessories to the fixture Secure the included mini SAFETY CABLE to the BARN DOOR and the top lock 1 Lift up lock on top of fixture and insert GEL FRAME into t...

Page 12: ...ional grade rigging clamp to the fixture using an M10 screw fitted through one of the 3 holes of the yoke bracket The fixture provides a built in rigging point for a SAFETY CABLE Be sure to only use t...

Page 13: ...installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture is fully operational in the sp...

Page 14: ...and DOWN buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field Pressing the ENTER button once more w...

Page 15: ...age TV Architec Theatre Set Dimmer Curve Mode Disp Set ADDR Disp CH Salve Set Information to Display on LCD Fan Set Led Fan Auto High Low Set LED Fan Speed Gamma 2 0 2 2 2 4 2 8 Set Gamma Brightness F...

Page 16: ...www elationlighting com 16 DIMMER CURVE MODES Dim Curve Select desired DIMMER MODE Standard Stage TV Architectural Theatre...

Page 17: ...TION 1CH 2CH 3CH 4CH 1 1 1 1 DIMMER INTENSITY 000 255 Dimmer 0 to 100 2 DIMMER INTENSITY FINE 000 255 Dimmer FINE Adjustment 2 2 3 SHUTTER STROBE 000 031 LED OFF 032 063 LED ON 064 095 Strobe Effect S...

Page 18: ...sues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspectio...

Page 19: ...TROL CONNECTIONS 4 DMX Channel Modes 1 2 3 4 4 Button Touch Control Panel Manual Dimmer and Zoom Control Knobs Adjustable Refresh Rate Adjustable Gamma Brightness 180 Reversible LCD Menu Display DMX a...

Page 20: ...www elationlighting com 20 DIMENSIONAL DRAWINGS Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice...

Page 21: ...O P T I O N A L A C C E S S O R I E S ORDER CODE ITEM QUICK RIG CLAMP Low Profile Quick Release Clamp AC5PDMX5PRO 5 ft 1 5m 5pin PRO DMX Cable NEU088 3 ft 1m powerCON TRUE1 Power Link Cable Additiona...

Page 22: ......

Reviews: