background image

Duration:

1.   This function allows you to set how long the fog burst will last,  

      when in timer mode.

2.   You can adjust the length of the fog burst from one second to 

      200 seconds.

3.   To set the duration, turn the duration knob in a clockwise/counter-

      clockwise direction. Turning the knob clockwise will increase the 

      duration, turning the knob counter-clockwise will decrease the 

      duration. 

Interval:

1.   In timer mode, this function allows you to set the time interval 

      between fog bursts.

2.   Fog burst interval can be set from one second to 200 seconds.

3.   To set the interval turn the interval knob in a clockwise/counter-

      clockwise direction. Turning the knob clockwise will increase the 

      interval,  turning the knob counter-clockwise will decrease the 

      interval. 

Timer On/Off:

1.   This Function allows you to set the fogger on an automatic setting.  

      You can set the Interval, Duration, and as described at the top of 

      the page.

2.  This button allows you turn the timer function on and off. A glowing 

      yellow LED will indicate this function is activated. 

Continuous: 

When this button is pushed the fogger will run continuously without 

stopping until the button is pushed again or the tank runs out of fog 

fluid.

Manual: 

When this button is pressed it will emit fog as long as the button is 

held down.

  Ice Flow™  

 

 Remote Control Instructions

©

Elation Supply

®

  -  www.elationlighting.com  - Ice Flow™ Instruction Manual Page 11

©

Elation Supply

®

  -  www.elationlighting.com  - Ice Flow™ Instruction Manual Page 12

  Ice Flow™  

 

 

          Trouble Shooting

If you experience low fog output, pump noise, or no fog output at all, 

disconnect and discontinue use immediately. Do not continue  push-

ing the remote controlʼs activation button as this may damage the Ice 

Flow™. Check fluid level, the external fuse or breaker, remote connec-

tion, and be sure the wall outlet is sending power. If all of the above 

appear to be okay, and the unit fails to operate correctly, the unit may 

require  service.  Please  contact  customer  support  for  further  instruc-

tions. Please do not return the unit to your dealer without contacting 

customer support first.

To help prevent the unit from clogging, use Elation

® 

Clean Machine™ 

liquid. Clean Machine is recommended when storing your fogger for 
more than 1 week, or at least once a month as normal maintenance 
under regular usage. Clean Machine removes particle build up in the 
heater and gives longer life to the fog machine. Clean Machine is like 
a tune up for your fog machine! Clean Machine is available in gallon 
or quart bottles.

  Ice Flow™ 

 

 

              Clean Machine

  Ice Flow™ 

 

                    Draining Switch

The drain switch on the back is for emptying the water produced by 

the melted ice, out of the unit. There are two modes of draining the 

water, automatically and manually.

Auto ( I ) - 

A sensor inside the unit will activate the pump when a cer-

tain water level is reached. The pump will empty the water out of the 

unit.

Manual ( II ) - 

When the manual mode of draining is selected, the 

pump will turn on instantly and pump whatever water is in the unit, out 

of the unit.

Summary of Contents for Ice Flowe

Page 1: ...tomer Support Elation provides a customer support line to provide help and to answer any question should you encounter prob lems during your set up or initial operation You may also visit us on the we...

Page 2: ...if it becomes damaged in anyway Never operate this unit when it s cover is removed To reduce the risk of electrical shock or fire do not expose this unit rain or moisture Do not attempt to operate th...

Page 3: ...ress equals 4 Dip Switch 4 address equals 8 Dip Switch 5 address equals 16 Dip Switch 6 address equals 32 Dip Switch 7 address equals 64 Dip Switch 8 address equals 128 Dip Switch 9 address equals 256...

Page 4: ...n PIN 2 DMX and PIN 3 DMX of the last fixture 1 2 3 N Figure 4 1 Ground 1 Ground XLR Male Socket XLR Pin Configuration 3 Hot 2 Cold 2 Cold 3 Hot XLR Female Socket Pin 3 Data True positive Pin 2 Data C...

Page 5: ...on the rear unit Always be sure to maintain an adequate supply of Elation Brand Fog juice in the fluid reservoir Running the fog machine dry will cause pump failure and or clogging This is the larges...

Page 6: ...Supply www elationlighting com Ice Flow Instruction Manual Page 12 Ice Flow Trouble Shooting If you experience low fog output pump noise or no fog output at all disconnect and discontinue use immediat...

Page 7: ...sole discretion of Elation All products covered by this warranty were manu factured after January 1 1990 and bear identifying marks to that effect E Elation reserves the right to make changes in desig...

Reviews: