Elation Design Spot 300E Manual Download Page 37

 
 

Design Spot 300E™ 

©Elation Professional, Los Angeles Ca. 

37 

 

www.ElationLighting.com

   

 

11. WORKING WITH BUILT-IN PROGRAMS

 

The fixture comes equipped with a built-in DMX recorder that allows custom programs to be 

installed and recalled directly from the fixture’s control board. Programs can be created and 

stored using the fixture’s control board or by using an external DMX controller. The following 

instructions will detail the procedures for using the on-board system menu as well as using a 

DMX compliant controller. 

 

Memory Statistics: 

Quick Access Programs (Program Part): 3 

Total Number of Programs: 10 

Maximum Number of Steps (Scenes) per a Program: 64 

Total Number of Scenes (Steps): 250 

 

Step 1 – Building Scenes. 

The control will store a maximum of 250 scenes. These scenes are then used to create the 

programs. A program can store one or a maximum of 64 scenes. Keep in mind that a scene 

can only be access when it is stored in a “Program.” If you wish to build a static scene (a 

scene consisting of no movement) for a logo or gobo projection, the scene must be stored 

inside a program. To build a scene follow the instructions below: 

 

• 

Access the main menu and toggle to “Edit Programs” which is menu function 8. 

 

• 

Then tap the “ENTER” button and toggle to “Edit Scenes,” menu function 8-3. 

      • 

When you get to the “Edit Scenes” function tap the “ENTER” button. The screen will 

 

 

then change to Edit Scene 001, this will be menu function 8-3-1. You can then press 

 

 

the “ENTER” button to begin to edit scene 1 or use the “UP” and “DOWN” buttons to 

 

 

toggle to access scenes 2-250.   

 

•    Once in the scene edit screen you have access to the functions listed below.     

 

 

Tapping the “ENTER” button will instantly allow you to change the values of the   

 

 

selected function in real time. The values can be adjusted from 0~250. Once you   

 

 

achieved your desired value tap the “ENTER” button once again to automatically   

 

 

lock the value into the scenes memory. You can repeat the procedure for all     

 

 

functions listed below:         

 

 

 

-    “Auto Program” – Allows access to all of channels 21’s DMX traits.   

 

 

 

-    “PAN” – pan movement. 

Summary of Contents for Design Spot 300E

Page 1: ...Rev 4 21 2008 visage Version 1 0 Design Spot 300E Elation Professional 6122 S Eastern Ave Los Angeles Ca 90040 www elationlighting com...

Page 2: ...Design Spot 300E Elation Professional Los Angeles Ca 2 www ElationLighting com...

Page 3: ...ing and Installation 14 a Mounting Positions 14 b Mounting Points 15 c Securing 16 7 Understanding DMX 17 a DMX Cable Requirements 17 b DMX Terminator 19 c 3 Pin to 5 Pin Conversion 19 d DMX Addressin...

Page 4: ...ge and be sure all accessories necessary to operate the unit have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructio...

Page 5: ...n a R A number by contacting customer support at 323 582 3322 DISCHARGE LAMP WARNING This fixture is fitted with a discharge lamp which is highly susceptible to damage if improperly handled Never touc...

Page 6: ...ss paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time This device falls under protection class 1 Therefore it is essential tha...

Page 7: ...t Allow at least 30 minutes after disconnecting main power before you open the Design Spot 300E To prevent personal injury never touch the lamp if you are not absolutely sure it has cooled 5 Never loo...

Page 8: ...oisture 11 Do not attempt to operate this fixture if the power cord has become damaged or frayed Important Notice Damages resulting from the disregard of safety and general user instructions found in...

Page 9: ...rism and prism rotation with 16 prism macros Frost Filter for Soft and Hard Edge Spot Bright Phillips MSR Gold 300 2 Fast Fit Lamp 300w 8000K 750Hrs 22 000Lm Dimmer intensity from 0 100 Electronic Pow...

Page 10: ...dust The minimum distance between the fixture and a wall or flat surface should be at least 0 5 meter about 1 5ft Always install the fixture with an appropriate safety cable When installing the fixtur...

Page 11: ...sure to replace with an approved replacement Be sure the replacement lamp meets or exceeds the original lamp specifications failure to do so may damage the fixture and void the manufactures warranty...

Page 12: ...per optimization may add a yellow tint to the lamp output and reduce intensity The minimum deviation amount is 1 0mm Running the fixture within a lower deviation can cause damage to the lamp and or le...

Page 13: ...nal Los Angeles Ca 13 www ElationLighting com Please remember that a MSR GOLD 300 2 lamp is not a hot restrike lamp therefore you must wait approximately 15 minutes before you can attempt to strike th...

Page 14: ...the device when mounting removing or servicing the fixture Caution When install the fixture be sure there is no highly inflammable material within a distance of 1 5 feet Mounting The Design Spot 300E...

Page 15: ...ture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury CAUTION Be sure all electrical connections are performed by a qualified...

Page 16: ...o attached at least one properly rated safety cable to the fixture using on of the safety cable rigging point integrated in the base assembly Securing the Design Spot 300E Regardless of the rigging op...

Page 17: ...fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in the DMX chain at the beginning at the end or anyw...

Page 18: ...tic behavior DMX 512 control connection Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the moving head Please refer...

Page 19: ...the line Using a line terminator Elation part DMX T PACK will decrease the possibilities of erratic behavior 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for DATA transmission i...

Page 20: ...els DMX channels of each fixture That means changing the settings of one channel will only affect the selected fixture In the case of the Design Spot 300E which is a 16 channel fixture you should set...

Page 21: ...irm your setting Once a setting is saved the display will briefly readout OK to confirm a new setting has been made and locked into memory You may exit the main menu at any time without making any adj...

Page 22: ...us Pan Reverse Tilt Reverse Fine Resolution Pan Degree Dimmer Speed Feedback Movement Speed Mic Sensitivity ON OFF Close Hold Auto Music ON OFF ON OFF ON OFF 630 540 Slow Quick ON OFF Speed 1 4 70 0 9...

Page 23: ...dit Edit Program Rec Controller XX XX Automat scenes rec 8 1 Function Mode 8 1 1 Set DMX Address DMX address setting This function is used to set or adjust the fixture s starting DMX address Every dev...

Page 24: ...e control menu You can set the number of steps under Edit program You can edit the individual scenes under Edit scenes With this function you can run the individual scenes either automatically i e wit...

Page 25: ...is function resets the lamp ON time to zero Please reset the lamp ON time at every lamp replacement This procedure tracks the lamp running time so the lamp can be replaced at the end of it s recommend...

Page 26: ...he Mode Esc button to return to the main menu 8 3 2 Automatic La On When in the ON position this function will automatically turn the lamp on when power is applied to the fixture 8 3 3 Lamp On Via DMX...

Page 27: ...omatically be shut down This function can be set to activate at an internal temperature between 80 C and 139 C Inside temperatures below 90 C are not critical Temperatures above 90 C should lead to th...

Page 28: ...annel operation from 8bit 14 channels to 16bit 16 channels This function is on by default which allows for the Pan Fine and Tilt Fine channels to be accessed When this function is turned off the fixtu...

Page 29: ...default setting is 70 and setting range from 0 to 99 8 4 2 Service Settings These adjustments and settings should only performed by a technician familiar with the functionality of professional lightin...

Page 30: ...lay is designed to turn off during normal operation to avoid excessive light in situations that require an extremely dark environment This function will adjust the time delay the fixture will before i...

Page 31: ...he fixture for lamp optimization in a simple single step procedure This function will center the pan and tilt motors and at the same time open the shutter and bring the dimmer to 100 The pan and tilt...

Page 32: ...oard or by using an external DMX controller For detailed instructions on how to complete this task please see Section 11 Page 37 8 8 1 Select program This function allows the user to select one of ten...

Page 33: ...main in the fixture s memory even when the power to the unit is switched off Memory is backed up and retain by an internal power source that should last about five years Remote DMX addressing RDMX Add...

Page 34: ...55 When set to 8 you can adjust the starting address between 256 and 511 3 Use channel 3 to set your desired DMX starting address For example If you want to set the starting address to 57 set channel...

Page 35: ...o get a synchronized light show without the need of an external controller The fixtures will react to sound chasing to a synchronized light show Set To Slave This function will set the fixture to slav...

Page 36: ...listed in the previous Stand Alone section For the Slave units access the Set To Slave settings in the Function Mode menu and assign each slave fixture a designation Slave 1 Slave 2 Slave 3 etc 10 3 U...

Page 37: ...ored in a Program If you wish to build a static scene a scene consisting of no movement for a logo or gobo projection the scene must be stored inside a program To build a scene follow the instructions...

Page 38: ...e iris value Focus adjust the focus value Strobe adjust the strobe Dimmer adjust the dimmer intensity Scene Time set the hold time for the scene Input By Out this function will store a scene from an e...

Page 39: ...ENTER button to add a scene to the program Tapping the Enter button will automatically lock the selected scene into the programs memory Repeat the process until all the desired scenes have been added...

Page 40: ...an fine CHANNEL 3 Tilt Movement max 265 CHANNEL 4 16bit Tilt Movement tilt fine CHANNEL 5 Color Wheel CHANNEL 6 Cyan Filter CHANNEL 7 Magenta Filter CHANNEL 8 Yellow Filter CHANNEL 9 Gobo Wheel 1 Rota...

Page 41: ...vement 8bit Channel 4 Tilt fine 16bit Channel 5 Color Wheel 0 13 Open white 14 27 Color 1 28 41 Color 2 42 55 Color 3 56 69 Color 4 70 83 Color 5 84 97 Color 6 98 111 Color 7 112 127 Color 8 128 189 C...

Page 42: ...on from fast to slow 190 193 No rotation 194 255 Counter Clockwise gobo rotation from slow to fast Channel 11 Gobo Wheel 2 Fixed Gobos 0 13 Open 14 27 Gobo 1 28 41 Gobo 2 42 55 Gobo 3 56 69 Gobo 4 70...

Page 43: ...ation 194 255 Backwards prism rotation from slow to fast Channel 14 Focus 0 255 Continuous adjustment from far to near Channel 15 Shutter Control 0 31 Shutter closed 32 63 No function shutter open 64...

Page 44: ...3 Macro 17 144 151 Macro 18 152 159 Macro 19 160 167 Macro 20 168 175 Macro 21 176 183 Macro 22 184 191 Macro 23 192 199 Macro 24 200 207 Macro 25 208 215 Macro 26 216 223 Macro 27 224 231 Macro 28 23...

Page 45: ...er Dimmer motor reset 97 99 Other motor reset 100 119 Internal program 1 secne1 8 of EEPROM 120 139 Internal program 2 secne9 16 of EEPROM 140 159 Internal program 3 secne17 24 of EEPROM 160 179 Inter...

Page 46: ...ird attempt all the errors have not been corrected the fixture will make the following determinations 1 3 or more errors The fixture cannot function properly with three or more errors therefore the fi...

Page 47: ...dexing error The gobo is not located in the default position after start up or after a reset command This message will appear after a fixture reset if the gobo positioning magnetic indexing circuit ma...

Page 48: ...t on the main PCB The focus motor is not located in the default position after the reset Iris error This message will appear after the reset of the fixture and if the magnetic indexing circuit malfunc...

Page 49: ...ow any traces of serious wear and should rotate freely 4 Electric power supply cables must not show any damage material fatigue or sediments Never remove the ground prong from the power cable Further...

Page 50: ...with the product Elation Professional shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number h...

Page 51: ...uding warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or...

Page 52: ...Design Spot 300E Elation Professional Los Angeles Ca 52 www ElationLighting com 16 PHOTOMETRIC DATA...

Page 53: ...Design Spot 300E Elation Professional Los Angeles Ca 53 www ElationLighting com 17 GOBOS...

Page 54: ...Design Spot 300E Elation Professional Los Angeles Ca 54 www ElationLighting com 18 DIMENSIONAL DRAWINGS...

Page 55: ...Design Spot 300E Elation Professional Los Angeles Ca 55 www ElationLighting com 19 CIRCUIT SCHEMATICS...

Page 56: ...Design Spot 300E Elation Professional Los Angeles Ca 56 www ElationLighting com...

Page 57: ...ti reflex Color 8 replaceable dichroic filters plus white half color compatible Gobos Gobo wheel 1 7 interchangeable rotating gobos plus open 4 glass Gobos Gobo wheel 2 7 fixed interchangeable gobos p...

Page 58: ...Design Spot 300E Elation Professional Los Angeles Ca 58 www ElationLighting com...

Page 59: ...Design Spot 300E Elation Professional Los Angeles Ca 59 www ElationLighting com...

Page 60: ...Rev 4 21 2008 visage Version 1 0 Elation Professional 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www ElationLighting com Info ElationLighitng com...