25
www.elationlighting.com
E R R O R C O D E S
Error Codes are subject to change without any prior written notice.
ERROR CODE
DESCRIPTION
PAN
The PAN movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or a defective motor IC drive on the main PCB). This error may
also be displayed if the head/yoke was blocked during a reset function.
TILT
The TILT movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or defective motor IC drive on main PCB). This error may also be
displayed if the head was blocked during a reset function.
CMY
The CMY movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or defective motor IC drive on main PCB).
CTO
The CTO movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or defective motor IC drive on main PCB).
COLOR
The COLOR wheel movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or defective motor IC drive on main PCB).
GOBO
The GOBO1 wheel movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or defective motor IC drive on main PCB).
GOBO_R
The GOBO1_R movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or defective motor IC drive on main PCB).
GOBO2
The GOBO2 wheel movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or defective motor IC drive on main PCB).
3_PRISM
The 3 PRISM wheel movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or defective motor IC drive on main PCB).
3_Prism1Rot
The 3 Prism1Rot movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or defective motor IC drive on main PCB).
Line_PRISM
The Line_PRISM wheel movement is not located in the default position after the
reset. This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or defective motor IC drive on main PCB).
Line_Prism1Rot
The Line_Prism1Rot movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or defective motor IC drive on main PCB).
FOCUS
The FOCUS movement is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or
there is a stepper motor failure (defective motor or defective motor IC drive on
main PCB).