DMX-512

DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and

controller manufactures as a  form  of  communication  between  intelligent  fixtures  and 

controllers. DMX allows all makes and models of different manufactures to be linked together 

and operate from a single controller. This is possible as long as all the fixtures and the controller 

are DMX compliant. A DMX controller sends the DMX data instructions to the fixture allowing 

the user to control the different aspects of an intelligent light. DMX data is sent out as serial 

data that travels from fixture to fixture via data “IN” and data “OUT” XLR terminals located on 

the fixtures (most controllers will only have output jacks).

DMX LINKING

To ensure proper DMX data transmission, always use the SIXPAR™ series IP rated DMX cables 

listed in the OPTIONAL ACCESSORIES section at the end of this manual. When using several 

DMX fixtures try to use the shortest cable path possible. Never split a DMX line with a “Y” 

style connector. The order in which the fixtures are connected in a DMX line does not influence 

the DMX addressing. For example; a fixture assigned a starting DMX address of 1 may be placed 

anywhere in the DMX chain, at the beginning, at the end, or anywhere in the middle. The DMX 

controller  knows  to  send  data  assigned  to  address  1  to  that  fixture  no  matter  where  it  is 

located in the DMX chain. The SIXPAR 200IP™ can be controlled via DMX-512 protocol and the 

DMX address is set via the control menu.

DMX Cable REQUIREMENTS (For DMX and Primary/Secondary Operation)

Your fixture and your DMX controller require a standard 3pin or 5pin XLR connector

for data input and data output. Also, remember that a DMX line must be daisy chained and 

cannot be split.

DMX-512 CONTROLLER CONNECTION

Connect the provided XLR cable to the female XLR output of your controller and the other side 

to the male XLR input of the SIXPAR 200IP™ . The diagram below illustrates a typical DMX-512 

connection when the fixture is in the 12 Channel Mode. You can chain multiple panels together 

through serial linking. Always be sure daisy chain your in and out data connections, never split 

or “Y” your DMX connections.

DMX-512 CONNECTION WITH DMX TERMINATOR

A DMX terminator should be used in all DMX lines especially in longer runs. 

The use of a terminator may avoid erratic behavior in your DMX line. A 

terminator is a 120 ohm 1/4 watt resistor that is connected between 

pins 2 and 3 of a male XLR connector (DATA + and DATA -). This fixture is 

inserted in the female XLR connector of the last fixture in your daisy chain 

to terminate the line. Using a line terminator will decrease the possibilities 

of erratic behavior. Use the SIXPAR™ DMX Terminator End Cap listed in 

the OPTIONAL ACCESSORIES section at the end of this manual.

DMX CONTROLLER

Address 1

Address 13

Address 25

Summary of Contents for 1236100103

Page 1: ...SIXPAR 200IP user manual...

Page 2: ...ormation contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professional USA 6122 S...

Page 3: ...A Only 5 Safety Guidelines 6 Overview 8 Installation 10 Remote Device Management RDM 13 DMX Setup 14 System Menu 16 Dimmer Mode 18 DMX Channel Functions and Values 19 Maintenance Guidelines 21 Specifi...

Page 4: ...subject to any warranty claims and or repairs Ensure all connections and end caps are properly sealed with a non conductive dielectric grease available at most electrical suppliers to prevent water i...

Page 5: ...its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warranty shal...

Page 6: ...ECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VOID YOUR MANUFACTURER S WARRANTY DAMAGES RESULT...

Page 7: ...perate fixture if the power cord is frayed crimped damaged and or if any of the power cord connectors are damaged and do not insert into the fixture securely with ease NEVER force a power cord connect...

Page 8: ...8 OVERVIEW POWER IN DMX IN DMX OUT Power Out Valve System Menu LCD Controls S Knobs to tighten Brackets Yokes Mounting Brackets Yokes Lens...

Page 9: ...wrench not included TORQUE SETTING 11 lbf in 12 7kgf cm lbf in Pound Force Inches kgf cm Kilogram Force Centimeters CAUTION DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES TO CONFIRM THE I...

Page 10: ...ace a professional equipment installer MUST be consulted to determine if the metal truss structure or surface is properly certified to safely hold the combined weight of the fixture clamps cables and...

Page 11: ...d through the center hole of the closed dual yokes The dual yokes of the fixture provides a rigging point for a SAFETY CABLE not included Be sure to only use one of the designated rigging points for t...

Page 12: ...d periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury PO...

Page 13: ...send out a signal to devices on the wire as well as allowing the fixture to respond known as a GET command The controller can then use its SET command to modify settings that would typically have to b...

Page 14: ...igned to address 1 to that fixture no matter where it is located in the DMX chain The SIXPAR 200IP can be controlled via DMX 512 protocol and the DMX address is set via the control menu DMX Cable REQU...

Page 15: ...the fixtures simultaneously If a different DMX address is set for each fixture each unit will start to listen to the channel number you have set based on the quantity of control channels DMX channels...

Page 16: ...selected menu will begin to flash Using the UP or DOWN buttons adjust the field until the desired value is displayed For example the CHANNEL CH menu variable field can be set to 06 07 08 or 12 Pressi...

Page 17: ...s 00 99 B00 99 Adjust BLUE Brightness 00 99 W00 99 Adjust WHITE Brightness 00 99 A00 99 Adjust AMBER Brightness 00 99 U00 99 Adjust UV Brightness 00 99 S00 99 Adjust STROBE SPEED 00 SLOW 0 1Hz 99 FAST...

Page 18: ...18 DIMMER MOD E...

Page 19: ...O STROBE 128 159 Strobe Pulse Effect in Sequence SLOW to FAST 160 191 LED ON NO STROBE 192 223 Random Strobe Effect SLOW to FAST 224 255 LED ON NO STROBE 9 COLOR MACROS 0 3 OFF 4 7 RED 8 11 GREEN 12 1...

Page 20: ...188 191 RED GREEN AMBER UV 192 195 RED BLUE WHITE AMBER 196 199 RED BLUE WHITE UV 200 203 RED BLUE AMBER UV 204 207 RED WHITE AMBER UV 208 211 GREEN BLUE WHITE AMBER 212 215 GREEN BLUE WHITE UV 216 21...

Page 21: ...ion service technician Should you need any spare parts please order genuine parts from an authorized Elation dealer Please refer to the following points during routine inspections A detailed electric...

Page 22: ...LCD Menu Display IP DMX In Out IP Power In Out With Wired Digital Communication Network SIZE WEIGHT Length 12 3 313mm Width 6 2 157mm Vertical Height 11 8 300mm Weight 12 6 lbs 5 7 kg ELECTRICAL THERM...

Page 23: ...23 DIMENSION S Drawings not to scale Specifications and improvements in the design of this unit and this manual are subject to change without notice PHOTOMETR IC DATA...

Page 24: ...een the device and the receiver Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected Consult the dealer or an experienced radio TV technician fo...

Page 25: ...25...

Page 26: ......

Reviews: