background image

10

I N STA L L AT I O N   G U I D E L I N E S

FLAMMABLE MATERIAL WARNING

Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyrotechnics.

ELECTRICAL CONNECTIONS

A qualified electrician should be used for all electrical connections and/or installations.

USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE POWER 
CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER 
OUTPUT ON THIS FIXTURE. CHECK SILK SCREEN FOR MAX AMPS.

MINIMUM DISTANCE TO OBJECTS/SURFACES

MUST BE 1.6 FOOT (0.5 METERS)
MINIMUM DISTANCE OF INFLAMMABLE MATERIALS

FROM THE SURFACE 1.6 FEET (0.5 METER)

MAXIMUM AMBIENT TEMPERATURE 113°F (45°C)

DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!

Fixture MUST be installed following all local, national, and country commercial electrical and 
construction codes and regulations. 

Before rigging/mounting the fixture to any metal truss/structure or placing the fixture on any 
surface, a professional equipment installer MUST be consulted to determine if the metal truss/
structure or surface is properly certified to safely hold the combined weight of the fixture, 
clamps, cables, and accessories.

Overhead rigging requires extensive experience, including, amongst others, calculating working 
load limits, installation material being used, and periodic safety inspection of all installation 
material  and  the  fixture.  If  you  lack  these  qualifications,  do  not  attempt  the  installation 
yourself. Improper installation can result in bodily injury.

Fixture ambient operating temperature range is 

14° to 113°F. (-10° to 45°C)

Do not use the fixture under or above this temperature.

Fixture should be installed in areas outside walking paths, seating areas, or away from areas 
were unauthorized personnel might reach the fixture by hand.

NEVER

 stand directly below the fixture when rigging, removing or servicing. 

Overhead  fixture  installation  must  always  be  secured  with  a  secondary  safety  attachment, 
such as an appropriately rated safety cable.

Allow approximately 10 minutes for the fixture to cool down before serving.

Summary of Contents for 1236100103

Page 1: ...SIXPAR 200IP user manual...

Page 2: ...ormation contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professional USA 6122 S...

Page 3: ...A Only 5 Safety Guidelines 6 Overview 8 Installation 10 Remote Device Management RDM 13 DMX Setup 14 System Menu 16 Dimmer Mode 18 DMX Channel Functions and Values 19 Maintenance Guidelines 21 Specifi...

Page 4: ...subject to any warranty claims and or repairs Ensure all connections and end caps are properly sealed with a non conductive dielectric grease available at most electrical suppliers to prevent water i...

Page 5: ...its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warranty shal...

Page 6: ...ECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VOID YOUR MANUFACTURER S WARRANTY DAMAGES RESULT...

Page 7: ...perate fixture if the power cord is frayed crimped damaged and or if any of the power cord connectors are damaged and do not insert into the fixture securely with ease NEVER force a power cord connect...

Page 8: ...8 OVERVIEW POWER IN DMX IN DMX OUT Power Out Valve System Menu LCD Controls S Knobs to tighten Brackets Yokes Mounting Brackets Yokes Lens...

Page 9: ...wrench not included TORQUE SETTING 11 lbf in 12 7kgf cm lbf in Pound Force Inches kgf cm Kilogram Force Centimeters CAUTION DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES TO CONFIRM THE I...

Page 10: ...ace a professional equipment installer MUST be consulted to determine if the metal truss structure or surface is properly certified to safely hold the combined weight of the fixture clamps cables and...

Page 11: ...d through the center hole of the closed dual yokes The dual yokes of the fixture provides a rigging point for a SAFETY CABLE not included Be sure to only use one of the designated rigging points for t...

Page 12: ...d periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury PO...

Page 13: ...send out a signal to devices on the wire as well as allowing the fixture to respond known as a GET command The controller can then use its SET command to modify settings that would typically have to b...

Page 14: ...igned to address 1 to that fixture no matter where it is located in the DMX chain The SIXPAR 200IP can be controlled via DMX 512 protocol and the DMX address is set via the control menu DMX Cable REQU...

Page 15: ...the fixtures simultaneously If a different DMX address is set for each fixture each unit will start to listen to the channel number you have set based on the quantity of control channels DMX channels...

Page 16: ...selected menu will begin to flash Using the UP or DOWN buttons adjust the field until the desired value is displayed For example the CHANNEL CH menu variable field can be set to 06 07 08 or 12 Pressi...

Page 17: ...s 00 99 B00 99 Adjust BLUE Brightness 00 99 W00 99 Adjust WHITE Brightness 00 99 A00 99 Adjust AMBER Brightness 00 99 U00 99 Adjust UV Brightness 00 99 S00 99 Adjust STROBE SPEED 00 SLOW 0 1Hz 99 FAST...

Page 18: ...18 DIMMER MOD E...

Page 19: ...O STROBE 128 159 Strobe Pulse Effect in Sequence SLOW to FAST 160 191 LED ON NO STROBE 192 223 Random Strobe Effect SLOW to FAST 224 255 LED ON NO STROBE 9 COLOR MACROS 0 3 OFF 4 7 RED 8 11 GREEN 12 1...

Page 20: ...188 191 RED GREEN AMBER UV 192 195 RED BLUE WHITE AMBER 196 199 RED BLUE WHITE UV 200 203 RED BLUE AMBER UV 204 207 RED WHITE AMBER UV 208 211 GREEN BLUE WHITE AMBER 212 215 GREEN BLUE WHITE UV 216 21...

Page 21: ...ion service technician Should you need any spare parts please order genuine parts from an authorized Elation dealer Please refer to the following points during routine inspections A detailed electric...

Page 22: ...LCD Menu Display IP DMX In Out IP Power In Out With Wired Digital Communication Network SIZE WEIGHT Length 12 3 313mm Width 6 2 157mm Vertical Height 11 8 300mm Weight 12 6 lbs 5 7 kg ELECTRICAL THERM...

Page 23: ...23 DIMENSION S Drawings not to scale Specifications and improvements in the design of this unit and this manual are subject to change without notice PHOTOMETR IC DATA...

Page 24: ...een the device and the receiver Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected Consult the dealer or an experienced radio TV technician fo...

Page 25: ...25...

Page 26: ......

Reviews: