2.7 Preset button
The preset button allows the user to reset the position value of the encoder. Remove the screw cover from
the back of the encoder and briefly press the button inside (see also par. 4.6, Preset Function). This button
is active only when the encoder is powered.
Note: Pressing the preset button result in a change of position reading. This can cause unexpected motion
which could result in personal injury or damage to the product or equipment.
2.8 LED Indicators
Four LEDs show the working conditions of the EtherNet/IP interface.
The Link1 and Link2 LEDs, display the status of the physical connection on the Ethernet interface.
Link1 / Link2
OFF
Power off or no Ethernet connection.
Steady Green
Ethernet connection established.
Yellow
Data transmission TxD/RxD.
Table 2.1 – Ethernet link indicators
The Mod LED shows the device status.
Mod
OFF
Power off.
Steady Green
Device in operation.
Flashing Green
Standby device, not configured, no IP address assigned.
Flashing Red
Major recoverable fault
(for example, inconsistent configuration).
Steady Red
Major unrecoverable fault, device not operational.
Flashing Green/Red
Self-test at power on.
Table 2.2 – Module status indicator
The Net LED show the status of the CIP connection.
Net
OFF
Power off or no IP address configured.
Flashing Green
Device not connected: an IP address is configured, but no CIP
connections are established.
Steady Green
Device connected: an IP address is configured, at least one CIP
connection is established.
Flashing Red
Connection timeout: a reset or a new CIP connection are
requested.
Steady Red
Error: the device has detected that its IP address is already in
use.
Flashing Green/Red
Self-test at power on.
Table 2.3 – Network status indicator