INSTRUCTION MANUAL
SPECIFICATIONS
Stroke: 250 ÷ 8000 mm
Resistance 5 KOhm ±10%
Linearity ±0,25%
(±0,3% for analogue output types)
Speed: 0.5/1 m/sec. (see the table)
Spring max torque: strokes
≤ 1250 mm = 600 g
Strokes from 1.5 to 4 m = 1000 g - Over: 2200 g
SUS304 stainless steel wire covered with nylon
0,6/1 mm
–
max load 16/60 Kg. (see the table)
Operating temperature -20 ÷ 70°C
(0 ÷ 70°C for analogue output
types) -
Relative moisture 35%-90%
Connections: cable 1 m long (
HPS-S
0.5 m)
Protection degree IP64 (
HPS-S
: IP50)
Type
Stroke
mm
Power
Speed
Wire Ø
/Max load
Type
Stroke
mm
Power
Speed
Wire Ø
/Max load
HPS-M-05
500
1W
1 m/sec
0.7 mm/ 23 Kg.
HPS-S-025
250
1W
0.5 m/sec
0.6 mm/ 16 Kg.
HPS-M-075
750
1W
1 m/sec
0.7 mm/ 23 Kg.
HPS-S-05
500
1W
0.5 m/sec
0.6 mm/ 16 Kg.
HPS-M-10
1000
2W
1 m/sec
0.7 mm/ 23 Kg.
HPS-S-10
1000
2W
0.5 m/sec
0.6 mm/ 16 Kg.
HPS-M-125
1250
2W
1 m/sec
0.7 mm/ 23 Kg.
HPS-L-30
3000
2W
0.6 m/sec
1 mm/ 60 Kg.
HPS-M-15
1500
2W
1 m/sec
0.7 mm/ 23 Kg.
HPS-L-40
4000
2W
0.6 m/sec
1 mm/ 60 Kg.
HPS-M-20
2000
2W
1 m/sec
0.7 mm/ 23 Kg.
HPS-L-50
5000
2W
0.6 m/sec
1 mm/ 60 Kg.
HPS-M-30
3000
2W
1 m/sec
0.7 mm/ 23 Kg.
HPS-L-60
6000
2W
0.6 m/sec
1 mm/ 60 Kg.
HPS-M-40
4000
2W
1 m/sec
0.7 mm/ 23 Kg.
HPS-L-80
8000
2W
0.6 m/sec
1 mm/ 60 Kg.
INSTALLATION
Make sure that the distance to be run by the wire does not exceed the transducer nominal stroke; stretching the wire over its
nominal stroke damages the transducer seriously, and causes the decay of the garantee right.
Use 4 M3 screws with the following specifications to fix the potentiometer:
HPS-M
screws M3x8 -
HLS-S
screws M3x6
–
HLS-L
screws M4x10
The wire must run out of the bushing without angle to obtain the best tolerance in measurements.
It is possible to hook the fixing end of the wire at a steady point and move the transducer body instead of the wire.
If the application is not a linear one, use a pulley with a proper diameter to smooth the rotation and avoid damaging the wire.
If the product works in a severe environment, such as in presence of oil, water, heavy dust, iron chipping or any powder which can
damage the wire, apply a protective cover.
CONNECTIONS
Carry out the connections as shown in the diagram hereunder. The cable shield is not connected inside the transducer.
HPS-M, HPS-S, HPS-L
HPS-M 10V, HPS-L 10V
HPS-M 420, HPS-L 420
The red and black
wires are connected
to the resistance
ends, while the
white wire is
connected to the
cursor
LINEAR WIRE
POTENTIOMETER
HPS-M
●
HPS-S
●
HPS-L
HPS