28
Chapter 4 Q & A
1. How to check a failed buffer?
There are two ways to know the buffer is failed:
(1) The fail message is displayed on the output window whenever the “load” command is
executed.
(2) The LED on the top of the hardware keeps blinking fast (5 times per second ) all the
time no matter users put power-on, or just push the red button.
2. What is “Frequency Mode”?
If the application system is below 200 kHz, the low frequency must be selected. Otherwise,
the high frequency is selected.
3. What is “Code Protected”?
Once the protection function is enabled, the contents of the OTP ROM would not be read
any more. The values displayed on the screen do not mean anything
4. What is status of LED?
(1) On under programming. Wait for LED turns off.
(2) Off: programming OK.
(3) Slow blinking (1.5 cycles per second): programming failed.
(4) Quick blinking (5 times per second): buffer reading failed
5. How to update your DWTR window software?
It is required to update the new function, when the new EM78P series are released. The
software and the firmware should be updated for a new version. The following describes
how to replace the old version with new one:
To update the software by catching the new software from the ELAN web. The IP address is
http://www.emc.com.tw, and to find the DWTR window version software of free software in
the “Customer” . Users also can ask their agents or ELAN to update with the new version.