These are the maximum wire run lengths when using the following cables to 
provide power to the VIA!Valet Touch Panel when the power supply is located 
in the “head-end”:

24 AWG 

Cat-5

18 AWG 

Stranded

16 AWG 

Stranded

14 AWG 

Stranded

110 ft. 

225 ft. 

575 ft. 

360 ft. 

Table 2-1: Maximum Wire Lengths

Summary of Contents for PVIA1 Valet

Page 1: ...PVIA1 Valet Single Zone VIA Valet Wall Plate Installation Manual...

Page 2: ......

Page 3: ...that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off a...

Page 4: ...heater Serial Control 11 S12 Series 12 SPP VIA Power 13 S8 Series 14 S6 Series 15 Connections 16 Rear Panel Connections 16 Standalone Connections 17 S12 Series Connections 18 S8 Series Connections 19...

Page 5: ...PVIA1 VALET EL AN HO ME S YST E M S Page 2 2008 ELAN Home Systems All Rights Reserved Troubleshooting 31 Appendix A Specifications 32 Appendix B Added Features 33 Warranty Back Page...

Page 6: ...d Use in ELAN S Series systems wherever a VIA Valet is needed Use for local system control perfect for Home Theaters Features Provides Power IR Video routing to a single VIA Valet IR output port Statu...

Page 7: ...5 1 3 Figure 1 2 Front Panel Callout Item Input Output Description 1 IR Output 3 5mm Mono Mini jack 2 9 VDC Power Sense In 9 VDC PWR Cube Connection 3 Coaxial Video Out Coaxial Video Cable Connector...

Page 8: ...ELAN Home Systems All Rights Reserved Page 5 1 2 Figure 1 3 Rear Panel Callout Item Input Output Description 1 CAT 5 Terminal Strip Terminate CAT 5 conductors 2 Coaxial Video Input Coaxial Video Cable...

Page 9: ...ion it is advisable to con sult a set of building plans and a list of equipment and map out each part of the system Make sure to carefully locate speakers keypads touchpads touchpanels and wire runs s...

Page 10: ...cation of a multi room system refer to the table on the following page for minimum wiring requirements BLUE WHITE BLUE ORANGE WHITE ORANGE GREEN WHITE GREEN BROWN WHITE BROWN 1 2 3 4 5 6 7 8 PIN COLOR...

Page 11: ...These are the maximum wire run lengths when using the following cables to provide power to the VIA Valet Touch Panel when the power supply is located in the head end 24 AWG Cat 5 18 AWG Stranded 16 AW...

Page 12: ...ls between the PVIA1 Valet and the VIA Valet Touch Panel The VIA Valet can be used for any stand alone non ELAN system applica tion or as a Home Theater controller The Figure 2 4 below shows a basic a...

Page 13: ...hows a VIA Valet100EM A PVIA1 Valet Wall Plate two VIA 70EMs and a PVIA4 Wall Plate controlling a stack of A V gear See VIA Tools for additional program ming details PVIA4 PVIA 4 VIDEO IN 1 2 3 4 16VD...

Page 14: ...x4 RS 232 PVIA 1 Valet TO VIA VALET IR OUT VIDEO IN 9VDC PWR9 16VDC PWR1 Local Port HOST RS 232 ELAN RS 232 HOST ELAN COM 1 COM 3 COM 2 COM 4 COM1 COM2 COM3 COM4 ETHERNET LINK RX TX IR LINK SENSE INP...

Page 15: ...n S12 The Figure 2 7 below shows one VIA Valet100EM Touch Panel one PVIA1 Valet Wall Plate four VIA 70EM Touch Panels and a SPP connected to an ELAN S12 S12 PVIA1 Valet SPP IR OUT VIDEO OUT 9VDC PWR9...

Page 16: ...WER 16VDC 10A 16VDC 4A 16VDC 1 5A POWER 16VDC 10A 16VDC 4A 16VDC 1 5A POWER 16V 1 5A Power Supply Connections PWR1 POWER SUPPLY ELAN PWR1 16V 1 5A Power Supply 16VDC 10 0A Ol 150mA VIA 1A PWR4 4A PWR1...

Page 17: ...2 10 below shows a VIA Valet100EM a PVIA1 Valet Wall Plate four VIA 70EMs and a SPP Precision Panel configured for use with an ELAN S8 6 PVIA1 Valet S8 6 PWR4 PWR1 IR OUT VIDEO OUT 9VDC PWR9 16VDC PW...

Page 18: ...a VIA Valet100EM a PVIA1 Valet Wall Plate three VIA 70EMs and a SPP Precision Panel configured for use with an ELAN S6 PVIA1 Valet S6 PWR4 PWR1 IR OUT VIDEO OUT 9VDC PWR9 16VDC PWR1 TO VIA VALET VIA...

Page 19: ...1 GND 16V GND SIR Z485 Z485 ST SNS IR V485 V485 16V White Blue Orange White Orange Green White Green Brown White Brown nc nc nc Blue Blue N C IR 485 485 G 16V G 16V Blue White Blue Orange White Orang...

Page 20: ...IRD4 Amplified Connection Block Signals originate at the VIA Valet100EM pass through the PVIA1 Valet Wall Plate then travel to the connection block where they are routed to each component NOTE This ap...

Page 21: ...details To Front of PVIA1 Valet S12 SPP VIA Connector IR 485 485 GND 16V GND 16V SN 16V GND 16V GND V485 V485 IR ST SNS Z485 Z485 SIR PVIA1 Valet Rear Figure 3 3 PVIA1 Valet to SPP Connections for S1...

Page 22: ...Plate to the VIA Valet100EM as shown below Connect IR V485 and GND between the PVIA1 Valet Wall Plate and the SPP as shown Multiple VIA s will connect in the same way Please consult the SPP Installat...

Page 23: ...to the S6 as shown below Multiple VIA s will connect in the same way NOTE It is recommended to use an SPP Precision Panel whenever possible When connecting to a SPP Precision Panel see the con nectio...

Page 24: ...rovided for a PWR1 PWR4 and PWR10 16 VDC Power Supply For complete SPP Applications Connections refer to the SPP Installation Manual G 5 V nc G 3 V V 4 G V nc 6 V G G 7 G 8 V V 9 G G 10 V RED BLACK IR...

Page 25: ...nect IR V485 and GND between the PVIA1 Valet Wall Plate and the VIA1 110 punchdown connector on the PVIA4 Punchdown an ELAN C45P to the XLink 110 connector and connect to the ELAN multi room controlle...

Page 26: ...all Wall Plate Connect a ELAN C45P to the screw terminal connec tors and connect to the ELAN multi room controller as shown Connect an RJ 45 cable from the VIA Net port on the PVIA 1 In Wall Wall Plat...

Page 27: ...D 16V GND V485 V485 IR ST SNS Z485 Z485 SIR PVIA1 Valet Rear PWR1 16V GND 16V GND V485 V485 IR ST SNS Z485 Z485 SIR PVIA1 Rear BLUE WHITE BL ORANGE WHITE OR GREEN WHITE GR BROWN WHITE BR ELAN C45P To...

Page 28: ...ojectors and TV monitors throughout the home The PVIA1 Valet features a pass through coaxial video connector to conve niently allow for video access from a video source such as an Z 880 S12 S8 or V883...

Page 29: ...s part of the main IR system in a stand alone applica tion IR is routed to an emitter as shown in Figure 3 10 or an IR distribution block connected to the IR OUT and sent to the source components with...

Page 30: ...27 IR Out Front Connecting Block Digital Music Server Satellite DVD IR Emitter IR Emitter IR Emitter Amplified IR Connection Block PVIA1 Valet PWR1 IR OUT VIDEO OUT 9VDC PWR9 16VDC PWR1 TO VIA VALET...

Page 31: ...voltage protection so that it has the ability to drive both Mini Emitters and High Output Emitters reliably Connect IR OUT and GND from the rear panel of the PVIA1Valet to CAT 5 cabling and terminate...

Page 32: ...ouch Panel VIA Valets can be powered locally by the power supply that comes with the PVIA1 Valet or powered by the power supply that is to be used with an SPP Precision Panel is used in an ELAN Multi...

Page 33: ...nel Connect an ELAN PWR9 9 VDC Power Supply into the 9 VDC connector on the PVIA1 Valet and plug it into the switched outlet of the source device The VIA Touch Panel can then sense whether source volt...

Page 34: ...y defective 4 Incorrect power connections 1 Connect PWR1 or PVIA1 Power Supply 2 Use PVIA1 PWR1 16VDC Power Supply 3 Test for 16VDC with a multimeter 4 Verify power con nections Valet connected to PVI...

Page 35: ...45 Video IN composite connector Video OUT F connector Power Terminal Sense Power Terminal Wiring Requirements Cat 5 Data RG 6 or RG 59 coaxial cable Composite Video Power PWR1 16VDC 1 5Amp included P...

Page 36: ...om s decor To change the faceplate use the following steps 1 Loosen and remove F Video Connector noting nylon washer placement 2 Remove four Phillips head screws from front faceplate note the four nyl...

Page 37: ...ace white face with optional black faceplate 4 Replace four phillips head screws and four nylon spacers DO NOT OVER TIGHTEN 5 Replace F Video Connector making sure the nylon washer is under the Compos...

Page 38: ...ELAN HOM E SY ST E M S PVIA1VALET 2008 ELAN Home Systems All Rights Reserved Page 35 Notes...

Page 39: ......

Page 40: ...ELAN the warranty obligations of ELAN shall in all respects conform to the warranty actually extended to ELAN by its supplier The foregoing warranties do not cover reimbursement for labor transportat...

Reviews: