Elan C2 Communications Controller Installation Manual Download Page 12

E L A N   H O M E   S Y S T E M S

INSTALLATION MANUAL

Page 10                                                                                                       © ELAN Home Systems  2009 • All rights reserved.             

C2

Items in package:

•  C2 Communication Controller

•  Rack Mount Brackets 

•  Power Cord

•  Installation Manual

Summary of Contents for C2 Communications Controller

Page 1: ......

Page 2: ......

Page 3: ...res Guide and front panel adjustments and switch settings C2 System Design Overview Provides a system design application overview of the C2 Communications Controller when used in the following applica...

Page 4: ...rmation should be followed Retain Information The safety and operating information should be retained for future reference Heed Warnings All warnings on the appliance and in the operating instructions...

Page 5: ...electrodes and requirements for the grounding electrode See the grounding diagram right Overloading Do not overload wall outlets and extension cords as this could result in fire or electric shock Obje...

Page 6: ...doit pas tre expos des gouttements d eau ou des claboussures et de plus u aucun objet rempli de liquide tel que des vases ne doit tre plac sur l appareil Un avertissment qu un appareil de construction...

Page 7: ...repairs This equipment may not be used on coin service provided by the telephone company Connection of party lines is subject to state tariffs Contact your state public utility commission for informat...

Page 8: ...E L A N H O M E S Y S T E M S INSTALLATION MANUAL Page 6 ELAN Home Systems 2009 All rights reserved C2...

Page 9: ...ion Chimes 12 Selectable Door Chimes 13 Home Automation 13 Telemute 13 Music Mute 13 On Hold Alert 13 Off Hook Alert 13 System Bypass 13 Quick Reference Telephone Features Guide 14 A Quick Explanation...

Page 10: ...e C2 To A Multi Line Telephone system 40 Digital Subscriber Line DSL 41 DSL Filters 41 Standalone Connections Without an ELAN Multi Room Controller 42 Pre Amp Amp 42 Receiver Based System 42 Stereo Re...

Page 11: ...rved Page 9 C2 Door Station DIP Switch Settings 60 VBRM Video Balun 61 Non VBRM Applications 62 DSF3 DSC3 Installation 63 DSC3 Doorbell Button Installation 64 DSS3 Installation 64 Appendix C Rack Moun...

Page 12: ...E L A N H O M E S Y S T E M S INSTALLATION MANUAL Page 10 ELAN Home Systems 2009 All rights reserved C2 Items in package C2 Communication Controller Rack Mount Brackets Power Cord Installation Manual...

Page 13: ...rol to any eight dwelling entrances is a touch tone away Simply pick up the phone to query a visitor or unlock a door Step Saving Convenience Park an incoming call while you take it on another phone W...

Page 14: ...conversation can be conducted without being heard over the in wall speakers when the second user picks up a handset on the same line Music On Hold Callers who are placed on hold enjoy music via the C2...

Page 15: ...aller on hold one minute after the phone is placed on hook the C2 will transmit a single beep over the speakers at 5 second intervals alerting you that the caller is still on hold Off Hook Alert If an...

Page 16: ...2 2 BLACK PMS167 BLACK PMS167 MATERIAL 230G GLOSS ART SIZE 3 75 X 8 5 SCALE 1 1 Must Be RoHS Compliant 10 09 08 07 06 05 04 03 02 01 01 10 Figure 1 2 Quick Reference Card The C2 s phone features are e...

Page 17: ...automatically mute allowing your page to be heard If you have a caller on the line they will automatically be put on hold You can get the caller back by simply pressing the flash hook Group Page If th...

Page 18: ...keypad The music will mute for the duration of the call Activate A Relay Up to four relay controlled devices can be connected to the C2 To activate Relay 1 press 1 1 To activate Relay 2 press 1 2 To...

Page 19: ...e caller on hold while you page Pressing the flash hook button will bring the caller back on line If you hang up the phone after paging the person you paged need just pick up any phone in the house an...

Page 20: ...0 11 12 13 14 15 Figure 1 3 C2 Front Panel Controls Indicators Item Description 1 Mute Telemute Status LED 2 Line 1 2 Status LEDs 3 Page LED 4 Doorbell Status 1 4 LEDs 5 Relay Status 1 4 LEDs 6 Page O...

Page 21: ...c mute function 6 Default is OFF 2 Line 1 Line 2 Status Red Flashing Slow Wink Solid ON Incoming call Call On Hold Phone Off Hook Default is OFF 3 Page Active Red Solid ON During page function 7 Defau...

Page 22: ...GGERS 1 2 3 4 5 9 10 11 8 7 6 Figure 1 5 C2 Rear Panel Connections Item Description 1 Power Switch ON OFF 2 Sum and PG Trigger Outputs 3 5mm Mono DB1 and DB2 Trigger Outputs 3 5mm stereo 3 Audio Loop...

Page 23: ...and Audio Loop Output 2 Line 1 Music On Hold Input Level Adjusts the volume level of the music heard over Phone Line 1 3 Door Station Microphone Input Level Adjusts the volume level of all door statio...

Page 24: ...er 65 milliseconds or 85 milliseconds Used to eliminate intermittent drop outs during a phone conversation These drop outs usually 3 seconds in duration are caused when certain speaking voices usually...

Page 25: ...On Hold and relay functions PAGE AUDIO DOOR CHIME AUDIO ON HOLD ALERT OFF HOOK ALERT TELEMUTE ELAN VOLUME CONTROLS W OVERRIDE FEATURE ELAN DOOR DOORSTATIONS DSS3 DSF3 DSC3 STEREO SYSTEM RECEIVER PRE...

Page 26: ...quired in this application LOW VOLTAGE RELAYS FOR LIGHTING SPRINKLERS GARAGE DOOR ETC ELAN DOOR STATION 1 ELAN DOOR STATION 2 C2 COMMUNICATION CONTROLLER S66A POW ER OUTPUTS DB1 DB2 12V GND NC C NO NC...

Page 27: ...IN OUT PG DBOUT MOHIN MONO SUM PG VCO TRIGGERS ZONE 4 ZONE 5 ZONE 6 ZONE 4 ZONE 5 ZONE 6 VIA NET OUT ZONE 1 ZONE 2 ZONE 3 VIA NET IN 2 3 4 5 6 7 IN OUT IN OUT SOURCE IR OUTPUTS 1 2 3 4 5 6 ELAN SENSE...

Page 28: ...OUTPUTS DB1 DB2 12V GND NC C NO NC C NO NC C NO NC C NO 1 2 POW ER INPUTS DOORSTATION BUS RELAY1 RELAY2 RELAY3 RELAY4 AUDIOLOOP R L VIA NET OUT IN OUT PHONE LINE1 2 IN TELCO LINE1 2 IN OUT PG DBOUT M...

Page 29: ...OTE Trigger inputs 1 and 2 will always trigger the Door Chime assigned to Door Station 1 and Door Station 2 alerts respectively In order to differentiate between Door Stations 1 and 2 alerts and Trigg...

Page 30: ...respond to telephone commands These relays can be configured as Normally Open NO or Normally Closed NC Possible applications include garage door openers blinds gates or lifts 12V GND NC C NO NC C NO...

Page 31: ...y connect from the C2 s VCO connector to VC of the Volume Control Connect from the C2 s VCO connector to VC of the Volume Control Cat 5 is typically used for this purpose CAUTION ALWAYS remove power t...

Page 32: ...n Panel When connecting the C2 to a PVSE Precision Panel use an RJ 45 to pigtail connector Connect the Blue Override pin 1 wire to of the C2 s VCO connector Connect the White Blue Ground wire pin 2 to...

Page 33: ...ou want music to mute and the page doorbell audio to be heard over the house speakers SUM is used to trigger the page doorbell input of an ELAN controller such as a S66A S128P Use a 3 5 mono interconn...

Page 34: ...o the OFF position prior to making connections DRY CONTACT GARAGE DOOR RELAY NOTE Relay current limit is 4A MOTOR TO BLINDS 12VDC POWER SUPPLY C2 COMMUNICATION CONTROLLER 12V GND NC C NO NC C NO NC C...

Page 35: ...h Blu Wh Org Orange Blue Pin RJ25 RJ14 RJ11 Pair T R TIA 568A New USCO Old 1 X 3 T White Green Orange 2 X X 2 T White Orange Black 3 X X X 1 R Blue Red 4 X X X 1 T White Blue Green 5 X X 2 R Orange Ye...

Page 36: ...TE BLUE ORANGE WHITE ORANGE GREEN WHITE GREEN BROWN WHITE BROWN 1 2 3 4 5 6 7 8 PIN COLOR CODE FRONT CABLE Standard ELAN RJ 45 Pin Out TAB Figure 3 8 C2 to DSC3 Door Station Wiring Pinout Option 1 Cat...

Page 37: ...1 2 3 4 5 6 7 8 PIN COLOR CODE FRONT CABLE Standard ELAN RJ 45 Pin Out TAB Figure 3 10 C2 to DSF3 or DSS3 Door Station Wiring Pinout C2 to Trigger Inputs The C2 provides Cat 5 connections for basic t...

Page 38: ...to the T568A standard Cat 5 4 Pair UTP Wire Color Codes RING TIP RING TIP RING TIP RING TIP Brown Wh Brown Green Wh Green Orange Wh Orange Blue Wh Blue Pair 1 Pair 2 Pair 3 Pair 4 Line 1 TIP White Blu...

Page 39: ...plates To TH48 Expanision Hub if more phones needed Telephones Expa nsion Ports In O ut R T R T R T R T 4 3 2 1 Telephone E xpans ion Hub 4 lines x 8 phones 8 TH48 TELEPHONE EXPANSION HUB R T R T 2 1...

Page 40: ...E HUB with Surge Protection From Phone Company Surge RJ31X Disconnect Disconnect In Out Ports RJ31X R T R T R T R T 4 3 2 1 Telephone Master Hub w Surge Protection Model TH31SRG R T R T R T R T 4 3 2...

Page 41: ...on From Phone Company Surge RJ31X Disconnect Disconnect In Out Ports RJ31X R T R T R T R T 4 3 2 1 Telephone Master Hub w Surge Protection Model TH31SRG R T R T R T R T 4 3 2 1 4 3 2 1 From TELCO Surg...

Page 42: ...c onnec t From Telco Surge Warning RJ31X Disconnect In Out R T 4 R T 3 R T 2 R T 1 Telephone Output Cat 5 Orange Wh Org Blue Wh Blu 2 lines from telepone company Cat 5 Jumper included TH31 SRG TELEPHO...

Page 43: ...ary phone lines to provide a way to carry data and voice services simultaneously DSL Filters Installers will need to install a passive electronic filter known variously as a filter microfilter or a sp...

Page 44: ...peakers connected to the power amplifier PRE AMP MAIN OUTPUTS L R L R POWER AMP INPUTS AUDIOLOOP R L IN OUT PG DBOUT MOHIN MONO Figure 3 18 C2 to a Pre Amp Power Amp Stereo System Receiver Based Syste...

Page 45: ...LOOP OUT jacks to the Receiver s Tape Loop Inputs This allows the C2 s Page and Doorbell signals to be heard through the speakers connected to the receiver NOTE Only applicable when Tape Loop is acti...

Page 46: ...nd System 2 may occur Consult the manufacturer of the A B switch for time lag specifications L R L R PRE AMP 1 OUT POWER AMP 1 IN Y SPLITTER FEEDING THE A B SWITCH S PRIORITY INPUT SIGNAL SENSING A B...

Page 47: ...ivate automated devices that require voltage or contact closure such as lighting controls or VIA Touch Panel sequences using ELAN s SIM2 Sensor Integration Module C2 Rear OUTPUTS DB 1 DB 2 1 2 INPUTS...

Page 48: ...ors match on the jacks Red to Red White to White Connect a 3 5mm mono interconnect cable such as an ELAN IRIC from the SUM Trigger Output to the S66A s PAGE TRIG IN C2 Rear S66A Rear OUTPUTS DB 1 DB 2...

Page 49: ...P s PAGE TRIG IN NOTE When connecting multiple S86A P s use the PAGE TRIGGER OUT and PAGE OUT connections as shown on the following page When using the Group Paging feature the VIA Net connection not...

Page 50: ...C NO NC C NO NC C NO 1 2 POWER INPUTS RELAY 1 RELAY 2 RELAY 3 RELAY 4 AUDIO LOOP R L IN OUT PG DB OUT MOH IN MONO SUM PG VCO TRIGGERS 3 5mm Mono Interconnect Cable RCA Interconnect Cable Stereo 3 5mm...

Page 51: ...onnect cable such as an ELAN IRIC from the SUM Trigger Output to the S128P s PAGE TRIG IN NOTE When connecting multiple S128P s use the PAGE TRIGGER OUT and PAGE OUT connections as shown on the follow...

Page 52: ...PUTS RELAY 1 RELAY 2 RELAY 3 RELAY 4 AUDIO LOOP R L IN OUT PG DB OUT MOH IN MONO SUM PG VCO TRIGGERS 3 5mm Mono Interconnect Cable RCA Interconnect Cable Stereo 3 5mm Mono Interconnect Cable Figure 3...

Page 53: ...on the front of the C2 should begin to flash whenever the phones ring 1 Confirm symptom and homeowner s findings regarding REN at left 2 With a lineman s hand set test set or a single line corded touc...

Page 54: ...nnected between the C2 and the S86A Group Paging not pro grammed properly in software Connect VIA Net cable Correct Enable Group Paging in the configuration software If problem still exists call ELAN...

Page 55: ...e reset Remove power to the C2 for 10 seconds then turn power back on If problem still exists call ELAN Technical Support at 1 800 622 ELAN Door Station speaker squeals Microphone in telephone may be...

Page 56: ...me assignment Door Station DIP switch may be set incorrectly Make sure you have assigned the desired Door Chime to the correct Door Station Follow the instruction provide on your Quick Reference Card...

Page 57: ...4 C2 Adjustments Troubleshooting Procedures Symptom Possible Cause s What an authorized installer can do No Page or Door Chime audio or level is too low high Adjust Page Door Chime levels 1 If using t...

Page 58: ...ntrols Ensure that the Override Volume Jumpers are properly set for rotary volume controls 3b Electronic Volume Controls Verify that the Override Volume settings are properly set 4 Verify that the pow...

Page 59: ...r Inputs 2 Current limited 12VDC Output connect to dry closure only Connector Interfaces AC Power VIA NET IN OUT Trigger Output Trigger Input Relay VCO Connections Relay VC Power Audio Loop In Out Mus...

Page 60: ...oor Stations Models ELAN s two wire door station models include the DSS3 Surface Mount Door Station the DSF3 Flush Mount Door Station and DSC3 Flush Mount Door Station with Color Camera Designed to be...

Page 61: ...tch Relay 12VDC coil 2A contact rating Wiring Requirements Cat 5 1000ft max DSC3 Color Camera Specifications Imager 1 3 in CCD Auto Iris 1 50 1 100 000 sec Lux 05 min Resolution 480 TV Lines Horiz Vie...

Page 62: ...SF3 and DSC3 Door Stations use an ELAN DBK1000 Rough In Bracket during construction The DSS3 Door Station is designed to be surface mounted and utilizes four wall anchors and screw For best aesthetics...

Page 63: ...tion 2 Door Station 3 Door Station 4 Door Station DIP Switch Setting 1 1 ON 2 ON 3 ON 2 1 OFF 2 ON 3 ON 3 1 ON 2 OFF 3 ON 4 1 OFF 2 OFF 3 ON Door Station DIP Switch Setting 5 1 ON 2 ON 3 OFF 6 1 OFF 2...

Page 64: ...WR DS DS 5 VID DS DS VID 8 7 6 PWR GND DS DS 3 4 2 1 CONNECTED TO DSC3 DOOR STATION NOTE Installer can use either Quick Lock Connector or the RJ45 Jack to connect the DSC3 with camera but not both CON...

Page 65: ...Remove the camera power connector then strip back the insulation on the red and black camera power wires and connect the corresponding red and black conductors of the 18 2 AWG wire as shown in Figure...

Page 66: ...the DSC3 or DSF3 Trim Brackets The DSC3 ships ready for horizontal installation Should you choose to mount the DSC3 vertically the DBK1000 must also be mounted vertically and the camera module must be...

Page 67: ...AN suggests using RG59 for video and 18 2 for all other connects In this case the video balun should not be used NOTE ELAN recommends using the provided doorbell only A non ELAN doorbell has not been...

Page 68: ...and 4 screws Attach attach the door station and surface bracket as shown in Figure B 8 To install the DSS3 Door Station 1 Using the surface bracket as a template mark and drill the four corner holes...

Page 69: ...nt the brackets onto the C2 chassis from the front Figure C 1 Figure C 1 2 Ensure that the brackets are flush with the front of the C2 Install each of the eight screws included through the side mounti...

Page 70: ...E L A N H O M E S Y S T E M S INSTALLATION MANUAL Page 68 ELAN Home Systems 2009 All rights reserved C2 Notes...

Page 71: ...Notes...

Page 72: ...P N 9900991 REV F...

Page 73: ...anufactured by ELAN the warranty obligations of ELAN shall in all respects conform to the warranty actually extended to ELAN by its supplier The foregoing warranties do not cover reimbursement for lab...

Reviews: