El.Mo 090051541 User Manual Download Page 4

4

090051541

  

 

HELIOSD

 

-

  

USER MANUAL

[email protected]

elmospa.com

3. FEATURES

3. 1 General features

HELIOS control unit version "D" is equipped with a protection door with window for display and operating LED

indicators.
The manufacturer, EL.MO. S.p.A., declares that the HELIOSD radio devices comply with the 2014/53/EU direc-

tive. You can log into the elmospa.com website to read the full Declaration of Performance: registration is quick

and easy.

• Wireless system operating over differentiated frequences

• Support of 16 remote controls (

ATLANTE4

 or 

TAURUS

)

• High-sensitivity and high-selectability RF section

• Remote control 

VELA

 and 

VELAPLUS

 keypads (to 

be counted among remote control devices)

• Support of 48 wireless detectors 

(LUPUS, LUPUSC, 

VOLANS, VOLANSC, VIRGO, SCORPIO, DRACO) 

with 

random-assigned 34 billion digital codes  combinations

• Support of 

TYROS

 medical remote controls

• Self-learning of detector codes with R.A.C. anti-collision 

protocol

• 

ANTISCRAMBLE

 for remote control codes protection 

(selectable)

• Automatic acknowledgment of DRACO smoke detector 

(active 24H)

• Support of 2 NC terminal inputs to connect non-

powered detectors

When using these inputs (no. 47 and 48), the number 

of wireless inputs available diminishes

• Digital transmission over differentiated, pulsed frequences 

for LPDs (Low Power Devices).

• NC input for tamper detection (TAMPER)

• Management and setup of supervision procedure for 

detectors and 

HYDRA

 siren

• Entry Time, Exit Day/Night Time, general alarm time 

and tamper alarm time programmable

• Full management of alarm, tamper and discharged battery 

alerts from wireless detectors

• Drop-out activation alarm relay with C-NO-NC terminal 

outputs to connect SELV-operating devices

• Management of fault alerts from DRACO detector

• LED output for arming status

• Control of LYBRA, LYBRA/AL, GAIA, HYDRA, HYDRA-AL 

sirens (and chrome versions HYDRACR and HYDRACR-AL)

• Built-in radio trnsmitter to control 15 sirens and 15 

alarm devices/actuators

• Plastic housing featuring refined design, reduced 

dimensions, and keypad protection cover door

• Built-in telephone dialler for data/voice transmissions, 

with voice synthesis function and digital transmission 

in FAST FORMAT, SLOW FORMAT, ADEMCO CONTACT-

ID protocols

• Back-lit LCD display and function LED indicators

• 8 x 16-digit telephone numbers for voice transmission

• 16-key rubber keypad with 4 dedicated keys for  ARMING e 

DISARMING, DAY PARTIAL ARMING e NIGHT PARTIAL 

ARMING

• 2 x 16-digit telephone numbers and 2 differentiated 

codes for digital transmission to surveillance centres

• Three arming options: night, day and complete arming

• 4 x15-second voice synthesis messages 

(customizable)

• 6-digit user codes for management, control and configuration

• FOLLOW ME function to easily memorise a provisional 

telephone number

• Easy access to unit setup menu

• Phone calls block at unit disarming

• Audible keypad tone

• Phone call(s) block when listening to messages and 

pressing either key 5 (single) or key 0 (all).

• High-sensitivity receiving section: it can be reduced by 3dB 

using the internal jumper when testing operating range during 

unit installation

• Programmable from PC with supplied browser  (cable 

CP8/SER2 required) or using remote assistance 

browser WINASSIST.

• RF circuit with high-efficiency SMD ceramic antenna

• Built-in high-intensity piezo-electric siren

• Support of HALLEY remote RF module: can be wired to 

improve area coverage

• Built-in mains power unit with safety transformer

• Support of ATLAS actuators (15 max) for operating status 

remote repetition

• 6V 1,2Ah back up battery (not included)

• WALK TEST function to test detectors operating mode and 

the whole system

• Protected against housing opening

Summary of Contents for 090051541

Page 1: ...USER MANUAL HELIOSD Wireless intrusion detection system 090051541 IT08020000001624...

Page 2: ...indeed it does for every other electronic or mechanical Given the target of this article property and persons protection invite the user to proportion the protection level offered by the system to the...

Page 3: ...controlling wireless sirens and by sending voice messages to phone line subscribers or digital format alerts to surveillance centres HELIOSD unit can fully manage also special events like fire events...

Page 4: ...ts from DRACO detector LED output for arming status Control of LYBRA LYBRA AL GAIA HYDRA HYDRA AL sirens and chrome versions HYDRACR and HYDRACR AL Built in radio trnsmitter to control 15 sirens and 1...

Page 5: ...age LED indicator for TAMPER alarm LED ON alarm event Blinking LED alarm event is being logged Fast blinking LED display memory To display alarm events logged press key then keys to browse events and...

Page 6: ...expire Control unit detectors assigned to DAY mode are active and can generate alarm events 5 4 arm the control unit NIGHT mode Action Digit 6 character user code press key Effect EXIT TIME activates...

Page 7: ...key than use keys to browse events Press STOP to exit NOTE green LED shall be steady lit when the system is in idle mode When the system operates normally it may be blinking 6 3 system anomalies When...

Page 8: ...8 090051541 HELIOSD USER MANUAL info elmospa com elmospa com 7 SETUP DIAGRAMS General diagram...

Page 9: ...090051541 HELIOSD USER MANUAL 9 info elmospa com elmospa com User Interface diagram OK Dis Move cursor to the right Move cursor to the left Insert a pause P...

Page 10: ...s The control unit switches on but the display does not work properly cannot be displayed Reset the unit to factory default Check voltage at battery wires PHONE LINE The control unit does not communic...

Page 11: ...com elmospa com 10 DEVICES CLEANING Clean the control unit and alarm system components with a damp cloth using non corrosive detergents for plas tic surfaces Do not spray the detergent directly on th...

Page 12: ...SYSTEM BLOCK DIAGRAM 3 3 FEATURES 4 3 1 General features 4 4 KEYPAD DISPLAY AND LED INDICATORS 5 5 HOW TO 6 5 1 disarm the control unit 6 5 2 arm the control unit 6 5 3 arm the control unit DAY mode...