4 mm banana sockets for connection to the 
cell cable of a potentiostat or battery tester. 
Adapters for connection of 2 mm banana 
plugs are attached upon delivery.

 

2  Technical Data 

 

 

Dimensions: 119 mm (width) x 301 mm (depth) x 84/114 mm (height without/ with PAT-Cells) 

 

Operating temperature: -20 to +70°C 

 

Humidity: non condensing 

 

Weight: 0.67/3.00 kg (without/with PAT-Cells)  

 

IP-Protection Class: EN 60529 IP20 

3  Installation 

The PAT-Stand-4 should be placed on a flat, dry and clean surface, for example on a bench 
top, inside a temperature chamber or a glove box. 
 
 

 

 

 

 

 

 

 

 

4 mm banana 

socket 

Adapter  

4 mm to 2 mm 

Summary of Contents for PAT-Stand-4

Page 1: ...2017 EL CELL GmbH User Manual Release 1 3 PAT Stand 4 Docking station...

Page 2: ...es EL CELL GmbH maintains the right to make changes without further notice to products described in this manual to improve reliability function or design EL CELL GmbH does not assume any liability ari...

Page 3: ...Page 3 of 9 Release 1 3 User Manual PAT Stand 4 Content 1 Product Description 4 2 Technical Data 5 3 Installation 5 4 Cleaning 7 5 Unpacking 8 6 Spare Parts 8 7 Technical Support 9 8 Warranty 9...

Page 4: ...overed in detail by other manuals http el cell com downloads downloads manuals Features Docking station for up to four PAT series test cells ready for connection to a potentiostat or battery tester ch...

Page 5: ...ical Data Dimensions 119 mm width x 301 mm depth x 84 114 mm height without with PAT Cells Operating temperature 20 to 70 C Humidity non condensing Weight 0 67 3 00 kg without with PAT Cells IP Protec...

Page 6: ...ent operation modes see the table below Operation mode 1 Cell voltage control 1 vs 2 PAT Stand 4 1 1S 2 2S R Potentiostat WE WE Sense CE CE Sense RE Operation mode 2 Half cell voltage control 1 vs R P...

Page 7: ...t tissue Do not use aggressive chemicals for cleaning Protect the PAT Stand 4 from dust and moisture Cable colors and naming conventions Exemplary potentiostat WE WE Sense CE CE Sense RE BioLogic i e...

Page 8: ...of the required components Contact EL CELL if anything is missing or damaged NOTE Damaged shipments must remain within the original packaging for freight company inspection List of Components PAT Stan...

Page 9: ...Warranty does not cover defects damage or nonconformity resulting from abuse misuse neglect lack of reasonable care modification or the attachment of improper devices to the goods This Limited Warran...

Reviews: