background image

Manual

A 75F/R

Summary of Contents for A 75F/R

Page 1: ...Manual A 75F R...

Page 2: ...n gon varningsdekal p avfuktare A75F R blivit deformerad eller sliten skall en ny best llas och monteras fortast m jligt f r att s kerst lla st rsta m jliga s kerhet vid anv ndandet av avfuktare A75F...

Page 3: ...kan best llas som tillbeh r Alternativt st lls aggregatet upp p ett golvstativ eller annat plant och stabilt underlag intill en v gg Justera de st llbara f tterna s att avfuktaren st r v gr tt D avfuk...

Page 4: ...m2 Anslut timern mellan elmatning och avfuktaren Observera att denna timer beh ver nollanslutning N En arbetsbrytare b r monteras f re timern Externa fl ktar tillbeh r F r kad luftcirkulation kan en e...

Page 5: ...hj lp av arbetsbrytaren TERMOSTAT GT1 1 Termostat GT1 1 styr v rmebatteriet och r inst llbar 0 9 motsvarar ca 0 50 C Termostaten r placerad innanf r filterluckan Lossa de vre skruvarna p filterluckan...

Page 6: ...n ur v gguttaget eller sl ifr n arbetsbrytaren 2 Kontrollera varf r skyddet har l st ut och tg rda felet Orsaken kan vara elektriskt fel eller d lig luftcirkulation 3 Lossa de vre skruvarna p filterlu...

Page 7: ...ande El kretsen GARANTI Standardavtalet NL09 g ller f r El Bj rn AB s leveranser och produkter Enligt dessa best mmelser ansvarar El Bj rn AB f r fel som visar sig inom ett r fr n leveransen F r fackm...

Page 8: ...e A75F R dehumidifier are shown on this page If any of the warning signs on the A75F R dehumidifier are damaged or worn new signs must be ordered and attached as soon as possible to ensure maximum saf...

Page 9: ...ernative the device can be placed on a floor console or another flat stable surface close to a wall Adjust the feet so that the dehumidifier is horizontal When the dehumidifier has been supplied toget...

Page 10: ...1 5 mm2 min area Connect the timer between the electrical supply and the dehumidifier Note that this timer requires an N connection N A main switch should be installed in front of the timer External f...

Page 11: ...3 Selector C to position C 4 Refit the cover and switch on the dehumidifier using the main operation switch THERMOSTAT GT1 1 Thermostat GT1 1 controls the heating coil and is adjustable from 0 to 9 c...

Page 12: ...ch 2 Look for the cause of the protection being triggered and fix the fault 3 The cause may be an electrical fault or poor air circulation 4 Remove the upper screws on the filter hatch Hinge down the...

Page 13: ...rules WARRANTY El Bj rn AB s products and deliveries are regulated by Standard Agreement NL09 According to this Agreement El Bj rn AB is liable for faults arising within one year after delivery The p...

Page 14: ......

Page 15: ......

Page 16: ...El Bj rn AB Box 29 334 21 Anderstorp Tel 0371 588 100 Fax 0371 181 34 info elbjorn se www elbjorn com KL597014 SE 131210...