DISTRIBUTION PLATE CONFIGURATION
In order to complete your loop, all of the ports should be used as
marked in the diagrams.
One port of each type must be used.
In the eventuality that a GPU or CPU block is not installed into the
system, the respective inlet and outlet ports must still be connected
to each other.
When using Standalone pumps it is essential that the PUMP IN port
is connected directly to the Inlet of the pump so that the impeller
is always submerged during operation. Failure to do so will cause
permanent damage to the pump.
To make installation of the tubing with different motherboard
configurations easier, there are multiple connection options for the
GPU. One of the inlet and one of the outlet ports must be used.
All remaining and unused ports should be closed using the supplied
plugs and a 6mm Allen key.
EK recommends EK-Quantum Torque fittings.
GPU OUT
one must
be used
GPU IN
one must
be used
CPU OUT
CPU IN
FILL
RADIATOR
OUT
DRAIN
DIRECTLY TO PUMP IN