background image

- 3 -

EKWaterBlocks

@EKWaterBlocks

ekwaterblocks

ekwaterblocks

EKWBofficial

Thank you for purchasing our co-branded limited edition InWin 
909EK chassis. We hope you enjoy your new case.

Feel free to follow us on social media.

Before you start using this product, please follow the basic guidelines: 

Carefully read the manual before you begin the installation process! 

EK fittings require only a small amount of force to screw them 
firmly into place since the liquid seal is ensured by the rubber 
o-ring gaskets. 

The use of corrosion-inhibiting coolants is always recommended 
for any liquid cooling system. EK recommends any of the 
EKCryofuel coolants for worry-free usage.

Summary of Contents for 3831109821848

Page 1: ...USER GUIDE EK Quantum InWin 909EK Silver Limited...

Page 2: ......

Page 3: ...you start using this product please follow the basic guidelines Carefully read the manual before you begin the installation process EK fittings require only a small amount of force to screw them firml...

Page 4: ...CONTENT TECHNICAL SPECIFICATIONS 5 ACCESSORIES 5 DISTRIBUTION PLATE CONFIGURATION 8 PUMP INSTALLATION 9 RADIATOR AND FAN INSTALLATION 10 TESTING THE LOOP 11 CABLE MANAGEMENT GUIDES 11 SUPPORT AND SER...

Page 5: ...ength up to 250mm Motherboard Compatibility ATX Micro ATX Mini ITX and E ATX up to 277mm wide Drive Compatibility two 3 5 or 2 5 drives in the bottom chamber Maximum GPU Length 365mm Maximum GPU Width...

Page 6: ...ild Number Plate 1x 2 InWin 909EK Chassis Accessories M3x5 2 5 HDD Screws 10x M3x6 Fan Side Panel Spare Screws 6x Black M3x6 Fan Bracket Spare Screws 2x Nickel Motherboard Stand Off 11x Motherboard St...

Page 7: ...re installed distribution plate with an integrated cable management solution In addition there are mounting holes provisioned for up to two D5 Standalone pumps two XE 480 Radiators and eleven Vardar 1...

Page 8: ...ted directly to the Inlet of the pump so that the impeller is always submerged during operation Failure to do so will cause permanent damage to the pump To make installation of the tubing with differe...

Page 9: ...9 PUMP INSTALLATION D5 Standalone pumps can be installed directly to the chassis using the supplied M4x8 Countersunk screws and pre drilled mounting holes...

Page 10: ...AND FAN INSTALLATION Radiators and Fans may be mounted onto the 3 brackets outside of the case and then installed together EK recommends the use of ZMT 10 16mm tubing for the radiators and pumps to p...

Page 11: ...ts in the reservoir CABLE MANAGEMENT GUIDES The InWin 909EK also includes Cable Guides which can be used to manage individually sleeved cables ensuring each wire stays parallel without the need to dis...

Page 12: ...For assistance please contact http support ekwb com EKWB d o o Pod lipami 18 1218 Komenda Slovenia EU SUPPORT AND SERVICE...