Provide proper ground connection to the HV module. In order to prevent electrical breakdown, 

ensure that the distance between the bottom of HV module and the surface below is more than 

6 mm. 

 

Connect the +24V DC power supply to the HV module. The DC power supply must be able to 

provide the maximum current as per

 

2.2

 

T

ECHNICAL 

S

PECIFICATIONS

 

Turn on +24V DC power supply. 

Set the output voltage using the potentiometer (

#8

 in 

Figure 2

). Ways to control of the output 

voltage: 

1.

 

Measure  the  output  high  voltage  directly  if  your  control  equipment  is  capable  of 

measuring high voltage. 

2.

 

Alternatively, measure the voltage between points 

#6

 and 

#7

 in 

Figure 2

. This voltage 

converts to output voltage approximately as 1V~1 kV. 

 

Turn off +24V DC power supply. 

Connect the HV supply load. Check that the connection cables are firmly attached. 

HV output can be turned off when pins 

#6

 and 

#9

 in 

Figure 3

 are interconnected. 

 

 

Summary of Contents for PS-40

Page 1: ...HIGH VOLTAGE POWER SUPPLIES PS 40 PS 40C Technical Description Rev 2202 2022 Lithuania ...

Page 2: ......

Page 3: ...HNICAL SPECIFICATIONS 3 CHAPTER 3 DEVICE LAYOUT 4 CHAPTER 4 SAFETY 6 CHAPTER 5 QUICK START GUIDE 7 5 1 INSTALLATION OF PS 40 7 5 1 1 Ground the HV Power Supply 7 5 1 2 Connect DC Power Supply 7 5 1 3 Set HV Voltage 7 5 1 4 Connect the Load 7 5 2 INSTALLATION OF PS 40C 8 5 2 1 Ground the HV Power Supply 8 5 2 2 Connect CAN Cable 8 5 2 3 Connect DC Power Supply 8 5 2 4 Set HV Voltage 8 5 2 5 Connect...

Page 4: ...WER SUPPLY WITH POTENTIOMETER CONTROL 4 FIGURE 3 TOP VIEW OF THE HV POWER SUPPLY WITH CAN INTERFACE CONTROL C MODELS 5 FIGURE 4 CAN USB CONVERTER 8 FIGURE 5 CONTROL PANEL APPLICATION 9 LIST OF TABLES TABLE 1 MODELS 2 TABLE 2 MAIN COMPONENTS 2 TABLE 3 TECHNICAL SPECIFICATIONS 3 TABLE 4 CONTROLS AND CONNECTIONS OF THE HV POWER SUPPLY 5 ...

Page 5: ...s into validity since the shipment date Any evidence of improper use or unauthorized repair attempts voids the warranty For service warranty requests please contact EKSMA OPTICS UAB c o EKSMA Optics UAB Dvarcioniu st 2B LT 10233 Vilnius Lithuania Phone Fax E mail Website 370 5 272 99 00 370 5 272 92 99 info eksmaoptics com www eksmaoptics com ...

Page 6: ...eter PS 40C 1 3 0 5 1 3 30 By CAN interface PS 40 1 8 0 8 1 8 22 By potentiometer PS 40C 1 8 0 7 1 8 22 By CAN interface PS 40 2 6 1 6 2 6 15 By potentiometer PS 40C 2 6 1 0 2 6 15 By CAN interface PS 40 3 6 2 6 3 6 11 By potentiometer PS 40C 3 6 1 4 3 6 11 By CAN interface PS 40 4 0 3 0 4 0 10 By potentiometer PS 40C 4 0 1 6 4 0 10 By CAN interface Table 2 Main components Component Quantity Notes...

Page 7: ...arity Positive Maximum HV output power at maximal output voltage W 40 Output voltage ripple 0 5 Output voltage control Internal potentiometer CAN interface C models Low voltage DC requirements 23 5 25V 2100mA Maximum ambient temperature for operation C 45 Dimensions mm 160 70 35 Weight g 190 ...

Page 8: ...4 www eksmaoptics com Chapter 3 DEVICE LAYOUT Figure 1 Outline drawing and dimensions of the HV power supply Figure 2 Top view of the HV power supply with potentiometer control ...

Page 9: ...onnections of the HV power supply Port 1 24V DC supply input A 24V B GND 2 CAN terminator jumper 3 LED 24V or No errors on C models 4 CAN connector 5 1 GND for HV output 5 2 HV output 6 GND pins 7 Pin for HV measurement 1 1000 output 8 HV tuning potentiometer 9 HV output off pin HV output is off when pin connected to GND ...

Page 10: ...r only dry non conductive POLLUTTION occurs Warning The safety of the system incorporating HV power supply is the responsibility of the assembler of the system Operating the power supply is allowed to persons acquainted with the operation manual and having permission to deal with voltages over 1000 V Do not remove unit covers while power cable is connected to the mains if applicable WARNING Direct...

Page 11: ...L SPECIFICATIONS Turn on 24V DC power supply Set the output voltage using the potentiometer 8 in Figure 2 Ways to control of the output voltage 1 Measure the output high voltage directly if your control equipment is capable of measuring high voltage 2 Alternatively measure the voltage between points 6 and 7 in Figure 2 This voltage converts to output voltage approximately as 1V 1 kV Turn off 24V D...

Page 12: ...between the bottom of HV module and the surface below is more than 6 mm Connect CAN cable to connector 4 in Figure 3 from USB CAN converter and USB cable between USB CAN converter and PC Connect the 24V DC power supply to the HV module The DC power supply must be able to provide the maximum current as per 2 2 TECHNICAL SPECIFICATIONS Turn on 24V DC power supply Use Control panel application to con...

Page 13: ...us of HV power supply and save CSV file while need for technical service or consultation of manufacturer CSV file includes list of CAN control registers and actual settings Connect the load Check that the connection cables are firmly attached Turn on HV supply via CAN Browser or Control panel application ...

Reviews: