8
www.eksmaoptics.com
CAN-USB converter is recommended for operation. It can be ordered from Eksma Optics. It
comes together with software and a set of connection cables.
Figure 4.
CAN-USB converter
Provide proper ground connection to the HV module. In order to prevent electrical breakdown,
ensure that the distance between the bottom of HV module and the surface below is more than
6 mm.
Connect CAN cable from
USB-CAN converter
to connector
#7
in
Figure 3
and USB cable between
USB-CAN converter and PC.
Connect the +24V DC power supply to the HV module. “+24 V” LED indicator (
#2
in
Table 4
)
should light. The DC power supply must be able to provide the maximum current as per 2.2
T
ECHNICAL
S
PECIFICATIONS
.
Turn on +24V DC power supply. Use Control panel application to control via PC. It gives
possibility to turn ON/OFF and set high voltage output as well as to read-out actual status.