1.INFORMATION ABOUT THE INSTRUCTION
This manual includes a descriptive section as well as a section with drawings showing the main stages of assembly. The section
with drawings is in the part with directions for assembly. These instructions should be treated as original according to the records
of the European Directive 2006/42 / EC. These instructions contain important information about the product. Please read them
carefully and follow them.
2.INFORMATION BEFORE THE ASSEMBLY
Before installing the EVB package, its condition and correctness should be checked. Pay particular attention to the condition
of the straps and ladders (if any). The packed box and rails should be stored in a dry place until assembly. It is forbidden to
stack boxes, rest objects on boxes or place items on boxes. Prior to installation, the condition of the building’s EVB should be
assessed. If necessary, additionally attach the box or guides directly to the building or EVB. Additional reinforcements of the
RAFF-i box must be attached to the lintel of the building. The EVB package may only be installed in the RAFF-i box when it is in
a technically perfect condition. No additional structural elements or non-system fixings may be mounted on the box. They can
adversely affect the function of the EVB and lead to damage to it. The end positions of the EVB package are preset. In case
of de-programming, they must be set again in accordance with the manual of the motor used in the EVB package.
Electrical installations must be performed by authorized electricians in accordance with the requirements of the country where
the installation takes place. When working at greater heights, installers and construction elements must be secured against
falling. Some components of the RAFF-i system can be cut from sharp edges!
ASSEMBLY INSTRUCTION
OF THE RAFF-I EXTERNAL VENETIAN BLINDS
3.INSTALLATION OF THE EXTERNAL VENETIAN BLINDS
In order for the EVB to meet its technical properties, the correct production process and correct assembly are
important
EXAMPLES OF CONSTRUCTION VARIANTS
On the reveal in the version of a
visible box..
On the reveal in the flush-mounted
version of the box.
On the wall in a flush-mounte
version.
On the wall in the visible version.
On the window in the visible
version with the use of offsets.
On the window in the visible
version with the use of offsets at the
back and front (e.g., for a recess).