Ekol Clarity 30 Boiler Installation And Operating Instructions Manual Download Page 9

 
This stove is suitable for intermittent burning, and should not be used constantly for extended periods. Not suitable for 
overnight burning. 
 
Under certain abnormal weather conditions, e.g. down draughts, it may be difficult to get sufficient draw through the 
appliance to achieve good combustion.  When this happens, the stove should not be used. 
 

CLEANING/MAINTENANCE 
 

Regular cleaning of the stove is essential for safety and efficiency. The ash-pan should be emptied at least after every use, and 
during use if burning for longer periods.  
When cold, the inside of the stove should be given a regular sweep out. 
The flue and flue pipe will require cleaning with a suitable chimney brush, to minimise build up of soot and tar. 
 
The baffle plate inside the stove can be simply lifted out for easy access to the flueways (see Diagram Fig.1) 
 
You chimney will also require periodic sweeping. 
If the glass becomes stained from the inside, the air-wash vent may need opening more during use. The glass can be cleaned 
with a cloth and chemical stove glass cleaner, or the glass cleaning pad made by Schott. 
The high temperature paint which your stove is finished in should last many years with normal use, but when it does 
eventually require re-finishing, black heat resistant paint in spray cans can be purchased from most hardware stores. – Do not 
use regular paint which is not high temperature resistant. 
After prolonged periods of not using the fire, the stove and flue system should be checked for blockages prior to re-lighting. 
We recommend regular servicing and safety checks are carried out by a qualified engineer. 
 
There must be no unauthorised modification of the appliance.  Use only replacement parts recommended by the 
manufacturer. 
 

What to do in the event of a chimney fire:- 

 

 

cut off the air supply  to the stove, i.e. close the primary and secondary air supplies  

 

move any combustible materials well-away from the stove 

 

get everyone out safely 

 

make sure that the fire brigade has clear access 

 

call 999  

If you have any questions or concerns regarding the safe use of your stove, please contact us. 

Warranty 

Your stove is guaranteed to be free from manufacturing defects which would affect the performance of the stove. 

When supplied through an authorised dealer and when registered, your guarantee will extend to 5 years and is limited to the 

original purchaser and the original installation/ address. 

Guarantee terms are for supply of replacement parts only, returned to factory and does not include Grates, firebricks, glass, 

rope seals, paint, baffles, or internal lining plates. 

Claims for damage caused by incorrect use or installation, damage caused by over-firing or use of incorrect fuels and 

accidental damage will not be accepted. 

Copyright Saltfire Stoves Ltd, 2014 

Summary of Contents for Clarity 30 Boiler

Page 1: ...ALLATION AND OPERATING INSTRUCTIONS REF Ekol Claity 30 Boiler Wood Version MANUAL Version 1 1 MANUAL PUBLICATION DATE 22 01 2014 Recommended as suitable for exemption under section 21 of The Clean Air Act 1993 for use within UK Smoke Control Area ...

Page 2: ...king plate Inside the stove will also be an ash pan which sits underneath the grate and will require regular emptying You will also find a detachable tool for removal of the ash pan You will also find a glove which must be used when opening the door or when adjusting air vents when the fire is hot There is also a removable baffle plate which rests on the top of the cylindrical section of the water...

Page 3: ... Flue Draught Flue draught should be measured at full output when up to full operating temperature and must be within the following limits 12 to 18 Pascals If the flue draught at full output exceeds the upper limit then a suitable flue draught stabiliser must be fitted to avoid overfiring and to allow sufficient burn rate control We recommend that you have a qualified fitter install your stove The...

Page 4: ...a It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food an...

Page 5: ... outside but be very wet in the middle To test moisture split a log and deeply insert the probes of the meter into the centre of the log Liquid fuels must NEVER be used WARNING Wet timber should not be used as this will create excess tar deposits in the chimney and stove and could increase the risk of chimney fire Timber which is not of a suitable moisture content will also create more smoke and h...

Page 6: ...esn t it can be further tightened with a crosshead screwdriver Once a satisfactory closure is achieved the control arm can then be opened ready for use 3 Vent control at top of door this is the Secondary or Airwash supply this vent allows air in which is flushed down onto the glass helping to keep the glass clean and aiding cleanburning of the gases Moving slider to the left will minimise air flow...

Page 7: ...ork is complete The chimney is suitable and sound and has been swept and free from obstruction Adequate ventilation and provision for combustion air has been made That the stove installation has been carried out in accordance with Building Regulations and any applicable local regulations as well as these installation instructions That chimney draw has been checked and within specification The stov...

Page 8: ...n the fire bed add suitable kindling to prevent excessive smoke re establish the fire and follow the Ignition process above It is important that the stove is not overloaded with fuel It is important that the stove is not overloaded with fuel Reduced burn rates can be achieved by reducing the openings of the Secondary and Tertiary air vents Operation with the door open can cause excessive smoke The...

Page 9: ... can be purchased from most hardware stores Do not use regular paint which is not high temperature resistant After prolonged periods of not using the fire the stove and flue system should be checked for blockages prior to re lighting We recommend regular servicing and safety checks are carried out by a qualified engineer There must be no unauthorised modification of the appliance Use only replacem...