background image

 
 
Ekol Clarity 30 Boiler Woodburning Stove,  – INSTALLATION AND OPERATING INSTRUCTIONS. 
REF: Ekol Clarity 30 Boiler Wood Version,  MANUAL VERSION 1.1 
DATE: 22.01.2014 

 

INTRODUCTION 
 
SAFETY 
 

Safety is the most important consideration when using and installing your stove. If not installed and used correctly, a house 
fire could result. Installation must comply with relevant national and local Building Regulations and fire safety standards. 
 
IN THE EVENT OF CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES. 
 
Your stove will be heavy and care needs to be taken when lifting - 4 people will normally be required to lift. 

 
UNPACKING 
 

Your stove will have several of its components stored inside the stove itself for transportation.  
 
Do NOT drag the stove on its legs – it must be carefully lifted into place. 
 
Inside the stove will be a flue connector collar. This simply bolts with the fixings provided onto the top or rear outlet of the 
stove, depending on your choice of installation type. Ensure to secure the supplied circular blanking plate onto the other 
outlet using a good bead of fire cement to seal both the collar and the blacking plate. 
 
Inside the stove will also be an ash-pan which sits underneath the grate, and will require regular emptying. You will also find 
a detachable tool for removal of the ash-pan. 
You will also find a glove which must be used when opening the door or when adjusting air vents when the fire is hot. 
 
There is also a removable baffle plate which rests on the top of the cylindrical section of the water jacket and the rear of the 
firebox (see diagram fig1.) this plate can be removed periodically to aid cleaning of the stove flueways and for easier access 
to the flue system. It is vital that the baffle is always replaced before use. 
 

INSTALLATION 
 

Installation of your stove must comply with relevant local and national Building Regulations and fire safety standards. 
 

TECHNICAL 
 

Your stove has been tested to CE and British standards conforming to EN 13240. 
Model; “Ekol Clarity 30 boiler” 
Nominal heat output total  – 19.2 kW 
Nominal output to space – 9 kW 
Nominal output to water – 10.2 kW 
Net Weight of Stove - 220 kg. 
Max Height - 725 mm (see also Diagram Fig.2) 
Max Width - 767 mm 
Max Depth - 536 mm 
Flue Diameter - 150mm (6”) 
Mean flue gas temperature directly downstream of the flue spigot - 322 degrees C. (with closed doors). 
Flue gas mass flow – 15.8g/s 
Mean CO emission (at 13% Oxygen) – 0.48% 
Net Energy Efficiency 73.8% 
Maximum operating water pressure 2 BAR 
 

Summary of Contents for Clarity 30 Boiler

Page 1: ...ALLATION AND OPERATING INSTRUCTIONS REF Ekol Claity 30 Boiler Wood Version MANUAL Version 1 1 MANUAL PUBLICATION DATE 22 01 2014 Recommended as suitable for exemption under section 21 of The Clean Air Act 1993 for use within UK Smoke Control Area ...

Page 2: ...king plate Inside the stove will also be an ash pan which sits underneath the grate and will require regular emptying You will also find a detachable tool for removal of the ash pan You will also find a glove which must be used when opening the door or when adjusting air vents when the fire is hot There is also a removable baffle plate which rests on the top of the cylindrical section of the water...

Page 3: ... Flue Draught Flue draught should be measured at full output when up to full operating temperature and must be within the following limits 12 to 18 Pascals If the flue draught at full output exceeds the upper limit then a suitable flue draught stabiliser must be fitted to avoid overfiring and to allow sufficient burn rate control We recommend that you have a qualified fitter install your stove The...

Page 4: ...a It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food an...

Page 5: ... outside but be very wet in the middle To test moisture split a log and deeply insert the probes of the meter into the centre of the log Liquid fuels must NEVER be used WARNING Wet timber should not be used as this will create excess tar deposits in the chimney and stove and could increase the risk of chimney fire Timber which is not of a suitable moisture content will also create more smoke and h...

Page 6: ...esn t it can be further tightened with a crosshead screwdriver Once a satisfactory closure is achieved the control arm can then be opened ready for use 3 Vent control at top of door this is the Secondary or Airwash supply this vent allows air in which is flushed down onto the glass helping to keep the glass clean and aiding cleanburning of the gases Moving slider to the left will minimise air flow...

Page 7: ...ork is complete The chimney is suitable and sound and has been swept and free from obstruction Adequate ventilation and provision for combustion air has been made That the stove installation has been carried out in accordance with Building Regulations and any applicable local regulations as well as these installation instructions That chimney draw has been checked and within specification The stov...

Page 8: ...n the fire bed add suitable kindling to prevent excessive smoke re establish the fire and follow the Ignition process above It is important that the stove is not overloaded with fuel It is important that the stove is not overloaded with fuel Reduced burn rates can be achieved by reducing the openings of the Secondary and Tertiary air vents Operation with the door open can cause excessive smoke The...

Page 9: ... can be purchased from most hardware stores Do not use regular paint which is not high temperature resistant After prolonged periods of not using the fire the stove and flue system should be checked for blockages prior to re lighting We recommend regular servicing and safety checks are carried out by a qualified engineer There must be no unauthorised modification of the appliance Use only replacem...

Page 10: ... Reproduction of this document in whole or in part is prohibited unless written permission has been granted by Saltfire Stoves Ltd Johns Road Wareham Dorset UK BH20 4BG Customer Service 44 0 1929 555211 ...