EKO INSTRUMENTS CO., LTD. Ventilation Unit MV-01 Instruction Manual Ver. 4 

Pg.  9 

 

5.  Getting Started 

 

5 - 1 .   P a r t s   N a m e   a n d   D e s c r i p t i o n s  

Each part name and its main functions are described below. 

 

 

Parts Names 

A. Heater Unit 

B. Overcurrent protection   

C. Fan Unit 

D. Cable Connector 

E. Leveling Screws 

F. Fixed foot 

 

 

 

 

 

 

 

 

 

 

 

Figure 5-1. Parts Names 

 

 

1. Heater Unit 

Heater can be used together with the fan unit to increase the forced air temperature.    When the instruments 

are used in cold regions and/or snowy regions, turn on the heater unit to prevent snow and ice getting on the 

glass dome and sun screen. 

 

2. Overcurrent protection 

Overcurrent protection is included to prevent damage due to excessive temperature rise of the heater.   

 

* Do not operate the heater in case the ambient temperature will be over 50

  and the heater supply voltage 

more than DC16V. Overcurrent protection may be activated and stopped to supply to the heater current.   

Since the MV-01 cannot be used for snow melting, please operate the fan and heater beforehand.   

The heater should be used with the fan unit.   

 

Table 5-1. Parts Name 

Summary of Contents for M V - 0 1

Page 1: ...INSTRUCTION MANUAL MV 01 Ventilation Unit...

Page 2: ...4 Environment 3 2 5 CE Declaration 4 3 Safety Information 5 3 1 WARNING CAUTION 5 4 Introduction 7 4 1 Main Features 7 4 2 Package Contents 8 5 Getting Started 9 5 1 Parts Name and Descriptions 9 5 2...

Page 3: ...31 0 70 3050117 Fax 31 0 70 3840607 North America Region https eko usa com info eko usa com EKO INSTRUMENTS USA Inc 111 North Market Street Suite 300 San Jose CA 95113 USA Tel 1 408 977 7751 Fax 1 40...

Page 4: ...ith the WEEE Symbol figure Trash bin to alert our customers that products bearing this label should not be disposed of in a landfill or with municipal or household waste in the EU If you have purchase...

Page 5: ...er Model No MV 01 To which this declaration relates is in conformity with the following harmonized standards of other normative documents Harmonized standards EN 61326 1 2013 Class A Emission EN 61326...

Page 6: ...ly to the base or mast with bolts and nuts otherwise the instrument may drop due to gale or earthquake which may lead to unexpected accidents Make sure the instrument and the cables are installed in a...

Page 7: ...is an error in the type of power supply AC or DC or voltage for measurement and then connect this product If you make a mistake it may cause a failure or an accident of this product Do not supply mor...

Page 8: ...n the sensor dome and sun screen Pyranometer with ventilator can be mounted in horizontal or tilted plane which make it suitable for PV monitoring applications The Tacho output provides a data pulse t...

Page 9: ...ly Cable 1pc Main Body Fixing Bolts 2pcs M6 x100mm bolts used for fixing the MV 01 main body in installation position Fixing Bolts 3pcs M5 x 10mm bolts used for fixing equipment to MV 01 Fine pitch th...

Page 10: ...s are used in cold regions and or snowy regions turn on the heater unit to prevent snow and ice getting on the glass dome and sun screen 2 Overcurrent protection Overcurrent protection is included to...

Page 11: ...ials are used for cable and connector pin terminals are attached to the cable ends for easy connection with DC power supply and data logger If you require a longer cable than the standard 10m and or r...

Page 12: ...it on the center of the MV 01 from above Securely fix the fixing bolt which has been passed through the fixing hole of the solar radiation sensor to the MV 01 using the supplied hex wrench 4 Adjust th...

Page 13: ...cable are used Make sure the polarity is correct otherwise the fan will be damaged Voltage drop in AWG22 cable 0 17V 10m 2 2 Power Supply Heater Apply a power supply with a rated specification DC 12...

Page 14: ...on The frequency of this square wave output is proportional to the rotation of the shaft The tacho signal can be measured using a frequency meter or pulse counter 12VDC Pulse signal 100Hz 2 900rpm Fix...

Page 15: ...izontal level Cause directional response error Check Cable Monthly Check for any damages disconnection of cables and loose connector Damaged cables and or loose connectors may lead to malfunction Chec...

Page 16: ...so check for any obstacles like trash plants and bugs are not stuck in the fan Fan RPM is low Make sure the supply voltage is appropriate Long cables cause a supply voltage drop adjust to the appropri...

Page 17: ...sumption When DC12V input Fan 1 9W Heater 6 5W Operating Temperature Range 40 to 70 Ambient Temperature Tacho output Pulse 100Hz 2900 RPM Environmental Protection IP IP 54 equivalent IEC60529 Standard...

Page 18: ...s the dimension of MV 01 Table 7 2 Dimensions MV 01 A Fixing Holes Pitch 120 mm B Body Height Fan Unit part 53 mm C Fixed foot 16 mm D Overall width 138 mm Use fixed foot and leveling screws which are...

Page 19: ...es See 5 2 Installation 2 Wiring for power supply cable wiring details 7 4 Accessories List Table 7 3 Accessories List Option Items Remarks Output Cable Cable Length 20m 30m 50m Terminals Fork termina...

Page 20: ...asia com EKO North America 111 North Market Street Suite 300 San Jose CA 95113 USA P 1 408 977 7751 F 1 408 977 7741 info eko usa com https eko usa com EKO Europe Middle East Africa South America Lul...

Reviews: