background image

P.

3

CAUTION

• 

To reduce the risk of device interference,

 keep 

DUO at least 2 meters away from all RF emitters 
including Wifi routers and radios when operating 
or charging.

• 

To reduce the risks associated with infection

 

follow all cleaning and disinfecting instructions 
included in this manual. Establish and follow a 
cleaning and disinfecting schedule after each use.

• 

To reduce the risks associated with inaccurate 
data acquisition

 store and operate this device only 

as instructed in this manual. It is recommended 
that the battery be recharged within thirty minutes 
of the LED indicator turning red. Recharge the 
battery using only the wireless charging pad 
provided with the device. 

• 

DO NOT immerse the device in a liquid

 or subject 

it to any sterilization processes other than those 
described in this manual. The device is non-sterile. 

• 

To reduce the risks associated with very strong 
electromagnetic fields

 avoid using the device 

near strong radio frequency (RF) signals or 
portable and/or mobile RF devices. If sudden 
or unexpected sounds are heard, move away 
from any radio transmitting antennas. Using 
accessories, transducers, and cables not 
produced by Eko may result in increased RF 
emissions or decreased immunity of DUO.

• 

Please read, understand, and follow all safety 
information

 contained in these instructions prior 

to using DUO.  It is recommended that these 
instructions be retained for future reference.

• 

DUO contains a Bluetooth Class 2 wireless 
data link.

 The maximum radio frequency field 

strength generated by the device is below three 
volts per meter, a level that is considered safe to 
use with other medical devices. However, audio, 
video, and other similar equipment may cause 
electromagnetic interference. If such devices are 
encountered and cause interference, immediately 
move DUO away from that device and/or turn the 
Bluetooth feature OFF.

• 

To reduce the risks associated with 
environmental contamination

 follow applicable 

regulations when disposing of this device. DUO 
contains a rechargeable battery; please properly 
dispose of the device as mandated by local 
directives.

• 

No modification of this equipment is allowed.

 

There are no repairable parts inside DUO.

• 

Disperse any static electricity

 before using the 

unit.

• 

Warning: MR-unsafe!

 Do not expose the device 

to a magnetic resonance (MR) environment. The 
device may present a risk of projectile injury due 
to the presence of ferromagnetic materials that 
can be attracted by the MR magnet core. Thermal 
injury and burns may occur due to the metal 
components of the device that can heat during 
MR scanning. The device may generate artifacts 
in the MR image. The device may not function 
properly due to the strong magnetic and radio 
frequency fields generated by the MR scanner.

• 

This device does not detect or measure all heart 

rate, heart rhythm and heart waveform changes.

• 

The device has not been tested for use on infants 
weighing less than 10kgs. 

• 

Conductive parts of electrodes and associated 
connectors for Type BF Applied Parts, including 
the neutral electrode, should not contact other 
conductive parts including earth.

• 

Do not use DUO while it is charging.

• 

Do not use on patients with cardiac pacemakers 
or other electronic implanted devices.

• 

Do not use the DUO on a portion of the body with 
too much body fat, body hair or very dry skin, a 
successful recording may not be possible.

• 

Do not use DUO while charging your mobile 
device, this will cause electrical interference with 
the ECG signal.

• 

Do not store the DUO in extremely hot, cold, 
humid, or wet conditions. 

• 

Do not expose to strong electromagnetic fields. 

• 

Do not  use as sole basis for medication or 
treatment decisions.

• 

Do not take a recording if the electrodes are dirty. 
Clean them first.

• 

Do not use the DUO over broken skin or wound 
areas.

1.4

Caution

Summary of Contents for DUO E5

Page 1: ...User Manual Model E5...

Page 2: ...es Inc directly Please report any injury or adverse event to Eko using any of the contact methods below Eko Devices Inc 2600 10th St Suite 260 Berkeley CA 94710 USA General Assistance and FAQs ekodevi...

Page 3: ...y move DUO away from that device and or turn the Bluetooth feature OFF To reduce the risks associated with environmental contamination follow applicable regulations when disposing of this device DUO c...

Page 4: ...rence and 2 this device must accept any interference received including interference that may cause undesirable operation NO MODIFICATION Modifications to this device shall not be made without the wri...

Page 5: ...but not limited to patient body temperature and clean contact area The device uses a Bluetooth Class 2 wireless data link The Bluetooth range will be reduced when objects walls furniture people etc a...

Page 6: ...isclosure of any electronic patient data through the use of software If the user becomes unable to comply with a law or restriction that applies to use and disclosure of such data the user should not...

Page 7: ...power adapter The LED light ring on DUO will begin to flash to signal the charging status All of the LEDs in the ring will light up when the device is fully charged DUO should be periodically recharge...

Page 8: ...ted on the top face An LED ring illuminates when the device is powered on Power Save Mode DUO will automatically power off after 5 minutes of continuous inactivity To resume DUO press and hold the act...

Page 9: ...ing light up based on volume level The device is ON The filter change is indicated by the active LED in the LED ring rotating to a new position The device is ON and has low battery The red warning LED...

Page 10: ...dio press the device firmly against the skin to ensure good contact ECG Capture ECG by placing and orienting DUO on the chest The optimal position to capture ECG data is at an inward facing 45 angle a...

Page 11: ...e device and may affect battery life Operating Warnings Failure to follow care and maintenance recommendations could result in damage to the internal components of the device Internal damage to the pr...

Page 12: ...4 digit login PIN to simplify the login process on the Eko mobile app To create or edit a login PIN manually select the Menu icon on the top left of the home screen Select Account Settings PIN and fol...

Page 13: ...top right of the home screen Select the desired patient and select a recording to add notes to Scroll to the bottom of the recording screen Select Add Comment and begin typing your note Select the th...

Page 14: ...otes 25mm s and 10mm mV 7 3 Main Recording Screen 89 AT T 1 45 PM Hill Thomas Settings Modify Bluetooth Adjust Volume Change Audio Source iPhone speakers or DUO Earpieces Adjust Account Details Name U...

Page 15: ...PIN is recommended so that users do not have to enter full login information each time the App is opened Finally users may log out of the App from this screen 7 4 Settings Screen My Devices Audio Sett...

Page 16: ...ted with the patient Patients may be added to the list individually through manual input or syncing with compatible EHR services 7 5 Patients Screen Aaberg Mark Anonymous PS01CEP90784 Aortic stenosis...

Page 17: ...ok at 01 57 for me Martin Stemper 4 59pm RRR Murmur heard and Indicated Martin Stemper 4 59pm This is one of the more complicated afib cardiology characteristics Will address tomorrow You 4 59pm NOTES...

Page 18: ...ation in the configuration in which it will be used Guidance and Manufacturer s Declaration Electromagnetic Emission DUO is intended for use in the electromagnetic environment specified below The user...

Page 19: ...z 3 Vrms 150kHz 80 Mhz Portable and mobile RF communications equipment should be used no closer to any part of DUO including cables than the recommended separation distance calculated from the equatio...

Page 20: ...rding to Frequency of Transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 37 0 37 0 74 1 1 2 1 2 2 3 10 3 7 3 7 7 4 100 12 12 23 For...

Page 21: ...www ekodevices com 2016 Eko Devices Inc All Rights Reserved Eko the Eko logo and DUO are trademarks of Eko Other company and product names may be trademarks of their respective owners LBL 009 B...