8
code
Malfunction name
Possible cause
1
Controller Overcurrent
1
,
motor external U,V or W connection short circuit
2
,
motor parameter isn’t match
3
,
controller malfunction
2
Current Sensor Fault
1
,
motor U,V,W through the stator on the car body short circuit,resulting in
leakage.
2
,
controller malfunction
3
Precharge Failed
1
,
the positive end of the capacitor is connected with negative load,so that the
capacity can not be charged normally
4
Controller Severe
Undertemp
1
,
the operating environment of the controller is too harsh
5
Controller Severe
Overtemp
1
,
the operating environment of the controller is too harsh
2
,
vehicle overload
3
,
controller installation incorrect
6
Severe Undervoltage
1
,
battery parameter setting mistake
2
,
power consumption for non-controller system
3
,
excessive battery impedance
4
,
the battery is disconnected
5
,
the fuse is not connected ,or the main contactor is not connected.
7
Severe Overvoltage
1
,
battery parameter setting is incorrect.
2
,
excessive battery impedance
3
,
battery connection disconnected during regenerative brake
8
Controller Undertemp
Cutback
1
、
the controller operate under the restricted conditions
2
、
the operating environment of the controller is too harsh
9
Controller Overtemp
Cutback
1, the operating environment of the controller is too harsh
2
,
vehicle overload
3
,
controller installation incorrect
10
Undervoltage Cutback
1
,
low battery
2
,
battery parameter setting incorrect
3
,
non-controller system runs out of power
4, excessive battery impedance
5, the battery disconnected
6
,
the fuse is not connected ,or the main contactor is not connected.
11
Overvoltage Cutback
1
,
the regenerative braking current increase the battery voltage during the
regenerative braking
2
,
battery parameter setting incorrect
3
,
excessive battery impedance
4
,
battery connection disconnected during regenerative brake
12
+5V Supply Failure
1
,
the impedance of external load is too low
13
Digital Out 6 Failure
1
,
the impedance of external load is too low
14
Digital Out 7
Overcurrent
1
,
the impedance of external load is too low
15
Motor Temp Hot
Cutback
1
,
the motor temp reaches or exceeds the alarm temp set by program,
resulting in reduced current output
2
,
motor temp parameter setting incorrect
Summary of Contents for Walkie EB16EA
Page 15: ...13 3 Circuit circuit diagram a Circuit...
Page 16: ...14 b Hydraulic circuit Hydraulic circuit diagram with lateral...
Page 21: ...19 The door frame can be raised by loosening the adjusting screw...
Page 22: ...20 Door frame with side sliding Multistage door frame carriage Measuring instrument fork...