![eKey home KNX RS-485 Operating Instructions Manual Download Page 18](http://html1.mh-extra.com/html/ekey/home-knx-rs-485/home-knx-rs-485_operating-instructions-manual_2373769018.webp)
en
│
17
Step
Action
Description
Display
6.
/
Press
Λ
or
V
and select
OK
.
KNX ri index finger
OK
DEV1: HOME SCENARIO
DEV2: empty
DEV3: empty
DEV4: empty
7.
Press
OK
.
Swipe finger
or
Press [ESC]
8.
Swipe your finger
Max
enabled
always
S Finger R P
S1 ----------X---- - -
S2 --------------- - -
S3 --------------- - -
The ekey events “
S
ecurity” and “
Unknown
” do not need to be configured
in the
ekey multi control panel DRM
. They are automatically triggered
when the conditions are met.
Error displays and troubleshooting
Display
Meaning
Remedy
KNX LED off
There is no connection
to the KNX bus system.
Check the wiring of the KNX
bus system.
RS-485 LED off
The
ekey converter KNX
RS-485
is not supplied
with power.
Check the function and the
wiring of the power supply.
RS-485 LED
permanently on
There is no data
connection to the
ekey
finger scanner
.
Check that the ekey finger
scanner is functioning
properly.
Check the wiring between
the
ekey converter KNX RS-
485
and the
ekey finger
scanner
.