![eKey home KNX RS-485 Operating Instructions Manual Download Page 10](http://html1.mh-extra.com/html/ekey/home-knx-rs-485/home-knx-rs-485_operating-instructions-manual_2373769010.webp)
en
│
9
Event “
S
ecurity”
The ekey event “
S
ecurity” is triggered when the ekey finger scanner does
not recognize a finger several times in a row within a specified time span.
NOTICE
No settings need to be adjusted for this function in the ekey system (ekey
control panel).
You can set the following functions for the ekey event “
S
ecurity”:
Function
Settings
Description
switch
on/off
Switches an actuator on or off.
amount of
failed
attempts
0
–
50
The ekey event is triggered when a
finger is not recognized by the
ekey
finger scanner
the selected number of
times.
time zone
1-10 min
The number of unrecognized fingers
must occur within this time span.
Table 5:
Description of event “Security”
ekey home control panel mini 1
ekey home control panel mini 2
No settings need to be configured on the
ekey home control panel mini
.
The following ekey events are automatically triggered in the KNX system:
□
If a
finger is recognized, the event “ekey
E
vent 1” is triggered
.
□
If a finger is not recognized, the ekey event “
Unknown
” is
triggered.
□
The ekey event “
S
ecurity” is triggered when the set conditions
are met.
Use with
ekey
home control
panel mini