eKey home KNX RS-485 Operating Instructions Manual Download Page 1

OPERATING INSTRUCTIONS

en

ekey home

Summary of Contents for home KNX RS-485

Page 1: ...OPERATING INSTRUCTIONS en ekey home...

Page 2: ...escription 4 System overview 4 Scope of delivery 5 Proper use and area of application 5 Purpose of the product 5 Technical specifications 5 System identification 6 Installation 7 Commissioning 7 Use 8...

Page 3: ...rized modifications are carried out on the system devices by the operator These operating instructions are not subject to updating We reserve the right to make technical modifications and change the p...

Page 4: ...or planning and configuring home automation systems with KNX bus system FS Finger scanner IN integra ekey control panel model KNX Name given to a field bus data transmission facility for home automati...

Page 5: ...d to carry out the electrical installation work Mount the ekey home converter KNX RS 485 in a secure internal area in the distributor This prevents tampering from the outside Product description Fig 1...

Page 6: ...tions exclusively with the ekey home and ekey multi biometric access control systems from ekey The ETS5 software for planning and installing KNX systems is used to configure the ekey home converter KN...

Page 7: ...y home control panel mini 2 See Use with ekey home control panel mini page 9 ekey home control panel WM 1 ekey home control panel WM 3 See Use with ekey home control panel WM IN page 10 ekey home cont...

Page 8: ...ger scanner and the lock Commissioning NOTICE Extensive specialist knowledge is needed to configure a KNX system Commissioning should be carried out by a KNX specialist The ekey home converter KNX RS...

Page 9: ...cene scene number A scenario programmed in the KNX system with the scenario number is triggered Table 2 Description of ekey event 1 10 All 3 functions can also be activated simultaneously Event Unknow...

Page 10: ...red when a finger is not recognized by the ekey finger scanner the selected number of times time zone 1 10 min The number of unrecognized fingers must occur within this time span Table 5 Description o...

Page 11: ...umber F2 then the event ekey Event 2 is triggered in the KNX system Etc The ekey events Security and Unknown do not need to be configured in the ekey home control panel WM IN They are automatically tr...

Page 12: ...F00 E02 F01 E03 F02 E04 F03 6 Press OK and set CV KNX AVAILABLE to Y KNX settings CV KNX available Y E01 F00 E02 F01 E03 F02 E04 F03 7 Press V until the desired ekey Event E01 E10 is selected KNX sett...

Page 13: ...f you do not wish to give the ekey Events 1 10 E01 E10 descriptive names then you can skip steps 7 to 12 Assigning descriptive names is helpful when carrying out further configurations of the system C...

Page 14: ...NX event OK HOME SCENARIO CHILDREN F03 F04 4 Press OK Max ri index finger Relay 1 Relay 2 Double relay 5 Press or V to select the relay function Max ri index finger Relay 1 Relay 2 Double relay 6 Pres...

Page 15: ...cial mode Settings Reset 2 Press OK Settings Set time Master key plan Change relay times Config input DEV configuration DEV assignment 3 Press or V until DEV CONFIGURATION is selected Settings Set tim...

Page 16: ...ngs CV KNX available Y E01 S00 E02 F01 E03 F02 E04 F03 12 Press OK KNX settings CV KNX available Y E01 S00 E02 F01 E03 F02 E04 F03 13 Repeat steps 11 and 12 until you have finished entering the name o...

Page 17: ...play 1 Press or V to select the desired finger Max S1 le middle finger le index finger le thumb ri thumb finger ri index finger ri middle finger 2 Press OK KNX ri index finger OK DEV1 empty DEV2 empty...

Page 18: ...tomatically triggered when the conditions are met Error displays and troubleshooting Display Meaning Remedy KNX LED off There is no connection to the KNX bus system Check the wiring of the KNX bus sys...