After connecting the
network, the received
optical power of the optical
contact point is unstable
and has large continuous
change. The output RF
signal is unstable, too. But
the detected output optical
power of the optical
transmitter is normal.

The optical fiber active connector
types do not match, maybe the APC
type connect to PC type, make the
optical signal cannot normal
transmission.
The optical fiber active connector or
adapter may be polluted seriously or
the adapter has been damaged.

1. Check the type of optical fiber active
connector and adopt the APC type optical
fiber active connector to ensure the normal
transmission of optical signal.
2. Clean the polluted optical fiber active
connector or adapter. Specific operation
methods see “Clean and maintenance method
of the optical fiber active connector”.
3. Replace the damaged adapter.

10. Clean and maintenance method of the optical fiber active connector

In many times, we consider the decline of the optical power as the equipment faults, but

actually it may be caused by that the optical fiber connector was polluted by dust or dirt. Inspect the
fiber connector, component, or bulkhead with a fiberscope. If the connector is dirty, clean it with a
cleaning technique following these steps:

1.

Turn off the device power supply and carefully pull off the optical fiber connector from the
adapter.

2.

Wash carefully with good quality lens wiping paper and medical absorbent alcohol cotton. If
use the medical absorbent alcohol cotton, still need to wait 1~2 minutes after wash, let the
connector surface dry in the air.

3.

Cleaned optical connector should be connected to optical power meter to measure output
optical power to affirm whether it has been cleaned up.

4.

When connect the cleaned optical connector back to adapter, should notice to make force
appropriate to avoid china tube in the adapter crack.

5.

The optical fiber connector should be cleaned in pairs. If optical power is on the low side after
clean, the adapter may be polluted, clean it. (Note: Adapter should be carefully operated, so as
to avoid hurting inside fiber.

6.

Use compressed air or degrease alcohol cotton to wash the adapter carefully. When use
compressed air, the muzzle aims at china tube of the adapter, clean the china tube with
compressed air. When use degrease alcohol cotton, insert directions need be consistent,
otherwise can’t reach a good clean effect.

Summary of Contents for XC8602JE

Page 1: ...2013 2013 6 6 Version Version 1 1 XC8602JE Optical Receiver Manual ...

Page 2: ...in the Ethernet responder support remote network management optional The optical output port and network management interface are external or internal optional Built in high reliability low power consumption power supply 3 Technique Parameter Item Unit Technique Parameters Optical Parameters Receiving Optical Power dBm 9 2 Optical Return Loss dB 45 Optical Receiving Wavelength nm 1100 1600 Optical...

Page 3: ...cteristics Power Voltage V A AC 150 265 V B AC 35 90 V Operating Temperature 40 60 Consumption VA 14 Dimension mm 220 L 205 W 65 H Note The forward RF indexes above are tested when adopt NEC module Use other module the indexes will be a little different 4 Block Diagram 5 Relation Table of Input Optical Power and CNR ...

Page 4: ...e 4 Enter key 5 Down key 6 Up key 7 Power Interface 8 AC220V input port when AC220V power supply 9 AC60V power pass inserter port 10 OUT1 11 20dB test port 12 AC60V feed port 13 FZ110 or FP204 14 AC60V power pass inserter port 15 OUT 2 16 Transponder connecting wire 17 Optical fiber access port 18 RJ45 interface or external optional 19 Network cable in 20 Operating instruction 21 Switching power s...

Page 5: ...eiver Receiver Manual Manual Manual 4 7 Function Display and Operating Instruction Mode Mode selection button total twelve modes press the mode selection button to enter the corresponding status display twelve modes to cycle The following is the detailed instructions ...

Page 6: ...255 255 0 2 Connect the computer and responder can be direct connected and change the computer IP to 192 168 1 XXX XXX is any number from 0 to 255 except 168 start upper computer network management software then search the device and log in 3 Right click device icon and choose modify the device IP 4 Enter new IP address gateway and subnet mask 5 Click modify then exit it is done There will show ne...

Page 7: ... in the specified range 2 Recover the received optical power of the optical contact point by cleaning the optical fiber connector or adapter etc methods Specific operation methods see Clean and maintenance method of the optical fiber active connector 3 Check the RF signal level input the optical transmitter and adjust to the required input range When the input channels number less than 15 should h...

Page 8: ...he optical fiber connector was polluted by dust or dirt Inspect the fiber connector component or bulkhead with a fiberscope If the connector is dirty clean it with a cleaning technique following these steps 1 Turn off the device power supply and carefully pull off the optical fiber connector from the adapter 2 Wash carefully with good quality lens wiping paper and medical absorbent alcohol cotton ...

Reviews: