background image

Connections

6

24V

PWR RMT IN

DC INPUT

CH A+B

CH A

CH B

SIGNAL OUTPUT

8

7

6

5

4

3

2

1

8

7

6

5

4

3

2

1

A,B

CH

A+B

CH - A

LINK

SIGNAL  INPUT

CH - B

24V

AUDIO

DISTRIBUTOR

AUDIO

DISTRIBUTOR

DC INPUT

EM CONTROL OUT

FIRE ALARM IN

18

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

COM

15

13

11

9

7

5

3

1

COM

2

16

14

12

10

8

6

4

EXPANSION

OUT

24V

FIRE
EM

18
17

COM
COM

18
17

FIRE ALARM IN

IN

CTRL-OUT

1~16

CTRL-IN

1~16

MADE  IN  KOREA

MADE  IN  KOREA

PUBLIC ADDRESS

PUBLIC ADDRESS

www.ekars.co.kr

EMERGENCY SWITCHER

EMERGENCY SWITCHER

POWER CONSUMPTION 2W

POWER CONSUMPTION 2W

MODEL NO : EES-2161

MODEL NO : EES-2161

CAUTION

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISK OF ELECTRIC SHOCK

DO NOT OPEN

OF FIRE OR ELECTRIC SHOCK 
DON'T EXPOSE THIS EQUIPMENT
TO RAIN OR MOISTURE.

TO REDUCE THE RISK

WA R N I N G

:

SN

CONTROL OUTPUT

B+
GND

18
17

CTRL-OUT

1~16

SPEAKER SELECTOR INPUT

B+
GND

18
17

CTRL-IN

1~16

RMT-2 INPUT

COM
ALL

18
17

EM CTRL INPUT

FIRE
EM

18
17

ATT CTRL

OUT

DC IN

TIMER IN

RMT OUT

POWER

EXP IN

EXP OUT

RMT-1 INPUT

COM
ALL

18
17

18

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

10

1

3

5

7

9

2

4

6

8

10

1

3

5

7

9

2

4

6

8

24V

MATRIX

LOGIC

MATRIX

LOGIC

CTRL-IN

1~16

CTRL-IN

1~16

CTRL-IN

1~16

REMOTE CONTROL

DC INPUT

24V

SIGNAL OUTPUT

MADE  IN  KOREA

MADE  IN  KOREA

PUBLIC ADDRESS

PUBLIC ADDRESS

www.ekars.co.kr

 CHIME & SIREN

 CHIME & SIREN

POWER CONSUMPTION 6W

POWER CONSUMPTION 6W

MODEL NO : EPC-2021

MODEL NO : EPC-2021

CAUTION

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISK OF ELECTRIC SHOCK

DO NOT OPEN

OF FIRE OR ELECTRIC SHOCK 
DON'T EXPOSE THIS EQUIPMENT
TO RAIN OR MOISTURE.

TO REDUCE THE RISK

WA R N I N G

:

SN

CHARGER OUTPUT

SN

TO REDUCE THE RISK OF FIRE

OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.

WA R N I N G

:

TO REDUCE THE RISK OF FIRE

TO REDUCE THE RISK OF FIRE

REPLACE ONLY WITH SAME TYPE FUSE.

CAUTION

:

CAUTION

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISK OF ELECTRIC SHOCK

DO NOT OPEN

MADE  IN  KOREA

MADE  IN  KOREA

AUTO BATTERY CHARGER

AUTO BATTERY CHARGER

POWER CONSUMPTION 170VA

POWER CONSUMPTION 170VA

PUBLIC ADDRESS

PUBLIC ADDRESS

www.ekars.co.kr

MODEL NO : EPB-2032

MODEL NO : EPB-2032

50/60Hz. 170VA

AC INPUT

220V-240V

FUSE

FUSE

OUTPUT RMS 120W

OUTPUT RMS 120W

GND COM

4

(22V)

8

(31V)

16

(44V)

70V

(41 )

100V
(83 )

POWER REMOTE IN

AC INPUT

AC FUSE

DC FUSE

F2AL 250V

F10AL 250V

ON

OFF

400Hz -3dB

HPF

INPUT LEVEL

MIN

MAX

BALANCED INPUT

0dBm (775mV) / 20K

BALANCED INPUT

0dBm (775mV) / 20K

DC INPUT

24V

24V

LINK

TO REDUCE THE RISK OF FIRE

OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.

WA R N I N G

:

TO REDUCE THE RISK OF FIRE

TO REDUCE THE RISK OF FIRE

REPLACE ONLY WITH SAME TYPE FUSE.

CAUTION

:

CAUTION

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISK OF ELECTRIC SHOCK

DO NOT OPEN

MADE  IN  KOREA

MADE  IN  KOREA

www.ekars.co.kr

 POWER AMPLIFIER

 POWER AMPLIFIER

OUTPUT POWER 120W RMS

OUTPUT POWER 120W RMS

PUBLIC ADDRESS

PUBLIC ADDRESS

MODEL NO : EPA-2123

MODEL NO : EPA-2123

SN

50/60Hz. 300W

220V-240V

POWER

REMOTE IN

CHARGER

IN

SWITCHED

OUT

UNSWITCHED

OUT

BATTERY

24V DC INPUT

SWITCHED

24V DC OUT
(ONLY AMP)

SWITCHED

24V DC OUT
(ONLY AMP)

SWITCHED OUT(3000W MAX)

SWITCHED OUT(3000W MAX)

UNSWITCHED

OUT(750W MAX)

UNSWITCHED

OUT(750W MAX)

24V

24V

TO REDUCE THE RISK OF FIRE

TO REDUCE THE RISK OF FIRE

REPLACE ONLY WITH SAME TYPE FUSE.

CAUTION

:

TO REDUCE THE RISK OF FIRE

OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.

WA R N I N G

:

CAUTION

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISK OF ELECTRIC SHOCK

DO NOT OPEN

MADE  IN  KOREA

MADE  IN  KOREA

www.ekars.co.kr

PUBLIC ADDRESS

PUBLIC ADDRESS

POWER DISTRIBUTOR

POWER DISTRIBUTOR

MODEL NO : EPD-2083

MODEL NO : EPD-2083

POWER CONSUMPTION 135VA

POWER CONSUMPTION 135VA

SN

50/60Hz. 135VA

AC INPUT

220V-240V

MATRIX

LOGIC

EML-2161

AUDIO

DISTRIBUTOR

EDA-2081

POWER AMP

EPA-2123
EPA-2243
EPA-2403

AUTO BATTERY

CHARGER

EPB-2032

POWER

DISTRIBUTOR

EPD-2083

CHIME /

SIREN

EPC-2021

EMERGENCY

SWITCHER

EES-2161

Summary of Contents for EPD-2083

Page 1: ...EPD 2083 Public Address Power Distributor OPERATING MANUAL ...

Page 2: ...nel Controls 5 5 Connections 6 1 SamHyoung Electronics Co Ltd 936 4 Kumuncheoun Ri Hyangnam Myun Hwaseong City Kyunggi Do Korea 445 922 Tel 82 31 432 5112 82 31 432 4422 Fax 82 31 352 7637 82 31 352 7649 Home Page http www ekars co kr http www samhyoung co kr E mail export ekars co kr trade ekars co kr ...

Page 3: ...d receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure CAUTION Although it is neither complicated to install nor difficult to operate your Power Distributor a few minutes of your time is required to read manual for a properly wired installation and becoming familiar with its many features and how to use them Please take a great care in unpacking your Power D...

Page 4: ...rating you can use remote control function even though power is on 3 Specifications DC Output DC 24V 2 5A Sensored battery protection threshold voltage Upper 28V DC Under 19 2 V DC Switched DC Output 1 circuit Unswitched DC Output 1 circuit Switched AC Output 8 circuit up to 3000VA Unswitched AC Output 2 circuit Remote Control Input 1 circuit Battery Output 8 circuits Power Requirements AC 220V 24...

Page 5: ...ype fuse when it is blown out 4 AC FUSE 1A 220V Replace it with the same type fuse when it is blown out 5 PROTECTION INDICATOR This LED indicates the condition of the protection circuit When the battery is over discharge the protection LED is ON and then power is off After power returns the battery is automatically charged and then LED is OFF 6 DC METER This meter indicates the internal rectified ...

Page 6: ...ED DC 24V for emergency equipment always turns on and it is independent with power switch or remote control 9 REMOTE INPUT CONTROL TERMINALS This terminal is for operating of remote control and emergency broadcast POWER REMOTE IN CHARGER IN SWITCHED OUT UNSWITCHED OUT BATTERY 24V DC INPUT SWITCHED 24V DC OUT ONLY AMP SWITCHED 24V DC OUT ONLY AMP SWITCHED OUT 3000W MAX SWITCHED OUT 3000W MAX UNSWIT...

Page 7: ...DUCE THE RISK OF FIRE TO REDUCE THE RISK OF FIRE REPLACE ONLY WITH SAME TYPE FUSE CAUTION CAUTION CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN RISK OF ELECTRIC SHOCK DO NOT OPEN MADE IN KOREA MADE IN KOREA AUTO BATTERY CHARGER AUTO BATTERY CHARGER POWER CONSUMPTION 170VA POWER CONSUMPTION 170VA PUBLIC ADDRESS PUBLIC ADDRESS www ekars co kr MODEL NO EPB 2032 MODEL NO EPB 2032 50 60Hz 170VA AC INPUT 2...

Page 8: ...fice 936 4 Kumuncheoun Ri Hyangnam Myun Hwaseong City Kyunggi Do Korea 445 922 Tel 82 31 432 5112 82 31 432 4422 Fax 82 31 352 7637 82 31 352 7649 E mail export ekars co kr trade ekars co kr Home Page http www ekars co kr http www samhyoung co kr Headquarter Overseas Dep MEMO PUBLIC ADDRESS TOTAL SOLUTION ...

Reviews: