background image

© 2014 Electronic Systems Protection, Inc.   /

   

Technical Support: 1-800-645-9721   /

   

espei.com 

                                                              

 

 
 

 

 

 
 

 

 

 

EV-12015, EV-12020, EV-20815, EV-20820, EV-23010  

 

 

 
 
 
 

 

 

 

 
 

User Manual

 

 
 

120 and 208/230 Volt Models 

Software Version

 

1.0

 

 

 

 

 
 

 

Summary of Contents for EnVision EV-12015

Page 1: ...2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com EV 12015 EV 12020 EV 20815 EV 20820 EV 23010 User Manual 120 and 208 230 Volt Models Software Version 1 0...

Page 2: ...User Manual 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com 1...

Page 3: ...CT MODEM FAX LINE 4 c CONNECT 10 100 1000 ETHERNET NETWORK LINE 4 d CONNECT EQUIPMENT 5 e CONNECT FILTER TO OUTLET 6 III HARDWARE 7 1 FILTER 7 a LCD EVENT MONITOR 7 I NORMAL OPERATION 7 II WIRING FAUL...

Page 4: ...sholds Under Voltage Event Recorder up to 65535 events Over Voltage Event Recorder up to 65535 events Power Outage Event Recorder up to 65535 events Surge Event Recorder up to 65535 events o Records s...

Page 5: ...x line Connect a phone cord from the wall jack to the Modem Fax modular jack labeled IN and then connect a second phone cord from the Modem Fax modular jack labeled OUT to the machine equipment to be...

Page 6: ...s au filtre ne d passe pas la tension maximale du circuit de d rivation Aseg rese de que el amperaje total del equipo conectado al filtro no supere la clasificaci n m xima del circuito de derivaci n...

Page 7: ...ther System On nor the Wiring Fault LED illuminates there is either no voltage at the receptacle or the magnitude of the line voltage is not acceptable less than 105 VRMS or above 140 VRMS for 120V pr...

Page 8: ...troubleshooting i Normal Operation 1 When the EnVision PCS Filter is plugged into a branch circuit outlet with correct wiring and acceptable line voltage the LCD Event Monitor will display the follow...

Page 9: ...der Voltages Off Under Voltages Record Over Voltages Record Over Voltages Off Surges Overload Last Recorded Event Outlet State OS On Off User Control UC Turn Outlets On Off Memory All Clear ALC Distur...

Page 10: ...circuit outlet voltage is not acceptable the Filter will disconnect power to its outlets and display the following information on the LCD Event Monitor above the over voltage shutdown threshold or bel...

Page 11: ...er Control is displayed 2 Next press the Scroll Button to select which memory record to erase Memory All Clear ALC Disturbance History Clear dhC Power Usage Clear PUC Disturbance Count Clear dcC Energ...

Page 12: ...nnections RJ 45 may remain in place ii Connect the Data Interface Cable into the USB port on your PC iii Connect the Data Interface Cable into the RJ 11 OUT Jack labeled Data Port on the Filter It is...

Page 13: ...n Green LED Off No power at output Incorrectly wired branch circuit outlet The LCD EVENT MONITOR will display the nature of the wiring fault Contact a licensed electrician to correct the branch circui...

Page 14: ...208 230V Models Adjustable from 0 V to 220 V Default 180 V Under Voltage Restore 120V Models Adjustable from 80 V to 110 V Default 105V 208 230V Models Adjustable from 160 V to 220 V Default 190 V Ove...

Page 15: ...er surge types may vary Modem Fax Protection Single telephone line surge suppression Ethernet Protection CAT6 network surge protection Dimensions EV 12015 EV 12020 EV 20815 EV 20820 EV 23010 6 125 W x...

Reviews: