Connections

7

AC INPUT

AC FUSE

F5AL 250V

OUTPUT RMS 400W

OUTPUT RMS 400W

COM

4

(40V)

8

(56.6V) (12.3 )

(25 )

70V

100V

ON

OFF

400Hz -3dB

HPF

INPUT LEVEL

BALANCED INPUT : 0dBm (775mV) / 20K

BALANCED INPUT : 0dBm (775mV) / 20K

MIN

MAX

DC INPUT

24V

50/60Hz. 1KW

220V-240V

TO REDUCE THE RISK OF FIRE

OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.

WA R N I N G

:

TO REDUCE THE RISK OF FIRE

TO REDUCE THE RISK OF FIRE

REPLACE ONLY WITH SAME TYPE FUSE.

CAUTION

:

CAUTION

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISK OF ELECTRIC SHOCK

DO NOT OPEN

MADE  IN  KOREA

MADE  IN  KOREA

PUBLIC ADDRESS

PUBLIC ADDRESS

www.ekars.co.kr

 POWER AMPLIFIER

 POWER AMPLIFIER

OUTPUT POWER 400W RMS

OUTPUT POWER 400W RMS

MODEL NO : EPA-2403

MODEL NO : EPA-2403

SN

LINK

LINK

24V

PWR RMT IN

DC INPUT

CH A+B

CH A

CH B

SIGNAL OUTPUT

8

7

6

5

4

3

2

1

8

7

6

5

4

3

2

1

A,B

CH

A+B

CH - A

LINK

SIGNAL  INPUT

CH - B

24V

AUDIO

DISTRIBUTOR

AUDIO

DISTRIBUTOR

CH2

CH1

POWER AMP IN

13

12

11

9

4

8

7

10

3

1

2

6

5

16

15

14

DC INPUT

SPEAKER OUTPUT CH2

SPEAKER OUTPUT CH1

24V

SPEAKER

SELECTOR

SPEAKER

SELECTOR

HOT

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

COM

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

POWER AMP IN

SPEAKER OUTPUT  9~16

18

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

SPEAKER OUTPUT  1~8

18

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

CONTROL  INPUT

18

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

CTRL-IN

1~16

ATT OUTPUT

18

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

ATT OUT

1~16

ATT CTRL

IN

B+
GND

18
17

NC
NC

18
17

COM
HOT

2~16
1~15

COM
HOT

2~16
1~15

RELAY

GROUP

RELAY

GROUP

NC
NC

18
17

NC
NC

18
17

INPUT

INPUT

CH8

CH7

CH6

CH5

CH4

CH3

CH2

CH1

DC INPUT

DC INPUT

24V

POWER AMP 100V OUTPUT

TO REDUCE THE RISK OF FIRE

OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.

WA R N I N G

:

TO REDUCE THE RISK OF FIRE

TO REDUCE THE RISK OF FIRE

REPLACE ONLY WITH SAME TYPE FUSE.

CAUTION

:

CAUTION

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISK OF ELECTRIC SHOCK

DO NOT OPEN

MADE  IN  KOREA

MADE  IN  KOREA

MONITOR PANEL

MONITOR PANEL

POWER CONSUMPTION 14W

POWER CONSUMPTION 14W

PUBLIC ADDRESS

PUBLIC ADDRESS

MODEL NO : EPM-2082

MODEL NO : EPM-2082

www.ekars.co.kr

SN

FUSE

FUSE

REMOTE IN

DC IN

DC FUSE

F300mAL 250V

MUTE

LEVEL

CHIME
LEVEL

MIC 5

LEVEL

MIN

MAX

MIN

MAX

MIN

MAX

AC FUSE

F100mAL 250V

AC INPUT

REMOTE

PRE1

PRE2

CHIME

AUX

REC

TAPE

CDP

TUNER

MIC-5

MIC-4

MIC-3

INPUT
1V Bal

OUTPUT

1000mV Bal

INPUT

100mV Unbal

OUTPUT
1V Unbal

INPUT

100mV Unbal

INPUT

300mV Unbal

INPUT

100mV Unbal

INPUT

1mV Bal

24V

24V

50/60Hz. 3W

220V-240V

TO REDUCE THE RISK OF FIRE

OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.

WA R N I N G

:

TO REDUCE THE RISK OF FIRE

TO REDUCE THE RISK OF FIRE

REPLACE ONLY WITH SAME TYPE FUSE.

CAUTION

:

CAUTION

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISK OF ELECTRIC SHOCK

DO NOT OPEN

MADE  IN  KOREA

MADE  IN  KOREA

 PRE AMPLIFIER

 PRE AMPLIFIER

POWER CONSUMPTION 3W

POWER CONSUMPTION 3W

PUBLIC ADDRESS

PUBLIC ADDRESS

www.ekars.co.kr

MODEL NO : EPR-2722

MODEL NO : EPR-2722

SN

POWER

REMOTE IN

CHARGER

IN

SWITCHED

OUT

UNSWITCHED

OUT

BATTERY

24V DC INPUT

SWITCHED

24V DC OUT
(ONLY AMP)

SWITCHED

24V DC OUT
(ONLY AMP)

SWITCHED OUT(3000W MAX)

SWITCHED OUT(3000W MAX)

UNSWITCHED

OUT(750W MAX)

UNSWITCHED

OUT(750W MAX)

24V

24V

TO REDUCE THE RISK OF FIRE

TO REDUCE THE RISK OF FIRE

REPLACE ONLY WITH SAME TYPE FUSE.

CAUTION

:

TO REDUCE THE RISK OF FIRE

OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.

WA R N I N G

:

CAUTION

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISK OF ELECTRIC SHOCK

DO NOT OPEN

MADE  IN  KOREA

MADE  IN  KOREA

www.ekars.co.kr

PUBLIC ADDRESS

PUBLIC ADDRESS

POWER DISTRIBUTOR

POWER DISTRIBUTOR

MODEL NO : EPD-2083

MODEL NO : EPD-2083

POWER CONSUMPTION 135VA

POWER CONSUMPTION 135VA

SN

50/60Hz. 135VA

AC INPUT

220V-240V

PRE  AMP

EPR-2722

AUDIO

DISTRIBUTOR

EDA-2081

POWER

DISTRIBUTOR

EPD-2083

MONITOR

PANEL

EPM-2082

SPEAKER

SELECTOR

EDS-2161

RELAY

GROUP

ERA-2161

POWER AMP

EPA-2123
EPA-2243
EPA-2403

PWR

AMP

IN

PWR

AMP

IN

PWR

AMP

IN

PWR

AMP

IN

PWR

AMP

IN

PWR

AMP

IN

PWR

AMP

IN

POWER  AMP

Summary of Contents for EPA-2403

Page 1: ...OPERATING MANUAL EPA 2403 Public Address Power Amplifier ...

Page 2: ...The Speaker 6 6 Connections 7 7 Specifications 8 1 SamHyoung Electronics Co Ltd 936 4 Kumuncheoun Ri Hyangnam Myun Hwaseong City Kyunggi Do Korea 445 922 Tel 82 31 432 5112 82 31 432 4422 Fax 82 31 352 7637 82 31 352 7649 Home Page http www ekars co kr http www samhyoung co kr E mail export ekars co kr trade ekars co kr ...

Page 3: ...ord receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure CAUTION Although it is neither complicated to install nor difficult to operate your Power Amplifier a few minutes of your time is required to read manual for a properly wired installation and becoming familiar with its many features and how to use them Please take a great care in unpacking your Power A...

Page 4: ...rotect against thermal run away MUTE START SYSTEM To protect speakers and remove pop noise start operating after 1 second BALANCED INPUT To allow you to build reliable system a balanced input is provided to reduce hum pickup from a long distance input cable and to avoid group loop problems USE OF EMERENCY BATTERY You can operate the power amplifier by using emergency battery for unexpected AC powe...

Page 5: ...G LED This LED indicates power is turned ON 3 OUTPUT LEVEL INDICATORS These LEDs indicates the output level of this amplifier 4 PROTECTION INDICATOR This LED indicates the condition of the protection circuit When the protection LED is ON the amplifier is not operating normally overheating please check the INPUT OUTPUT condition of the amplifier ...

Page 6: ...olume level of Input 7 SIGNAL INPUT JACK for 1 4 Phone Jack This input jack is for balanced input signal 8 SIGNAL INPUT JACK for XLR Receptacles Jack This input jack is for balanced input signal 4 Ω 8 Ω 7 0 V 1 0 0 V 4 0 V 5 7 V 1 2 Ω 2 5 Ω AC INPUT AC FUSE F5AL 250V OUTPUT RMS 400W OUTPUT RMS 400W COM 4Ω 40V 8Ω 56 6V 12 3 Ω 25 Ω 70V 100V ON OFF 400Hz 3dB HPF INPUT LEVEL BALANCED INPUT 0dBm 775mV ...

Page 7: ...ing of the amplifier by connecting more speakers than the unit is rated for If you are in doubt please consult a professional installer OUTPUT RMS 400W OUTPUT RMS 400W COM 4Ω 40V 8Ω 56 6V 12 3 Ω 25 Ω 70V 100V OUTPUT RMS 400W OUTPUT RMS 400W COM 4Ω 40V 8Ω 56 6V 12 3 Ω 25 Ω 70V 100V OUTPUT RMS 400W OUTPUT RMS 400W COM 4Ω 40V 8Ω 56 6V 12 3 Ω 25 Ω 70V 100V OUTPUT RMS 400W OUTPUT RMS 400W COM 4Ω 40V 8Ω...

Page 8: ...OPEN RISK OF ELECTRIC SHOCK DO NOT OPEN MADE IN KOREA MADE IN KOREA MONITOR PANEL MONITOR PANEL POWER CONSUMPTION 14W POWER CONSUMPTION 14W PUBLIC ADDRESS PUBLIC ADDRESS MODEL NO EPM 2082 MODEL NO EPM 2082 www ekars co kr SN FUSE FUSE REMOTE IN DC IN DC FUSE F300mAL 250V MUTE LEVEL CHIME LEVEL MIC 5 LEVEL MIN MAX MIN MAX MIN MAX AC FUSE F100mAL 250V AC INPUT REMOTE PRE1 PRE2 CHIME AUX REC TAPE CDP...

Page 9: ...ncy Response 80 Hz 17KHz 3 dB S N More than 85dB High Pass Filter Switch ON 3dB at 400Hz Power Requirements AC 220V 240V 50 60Hz DC 24V Power Consumption Net Weight kg lb 1000Watts 20 44 0 Dimensions 483 W x 133 H x 300 D mm 19 W x 5 2 H x 11 8 D inch 8 Specifications and design are subjected to change without notice for improvements ...

Page 10: ...Memo 9 ...

Page 11: ...Memo 10 ...

Page 12: ...618 Shihwa Industrial Complex 1378 Jungwang Dong Shiheung City Kyunggi Do Korea 429 450 Tel 82 31 432 5112 82 31 432 4422 Fax 82 31 432 5450 82 31 431 1690 E mail export ekars co kr trade ekars co kr Home Page http www ekars co kr http www samhyoung co kr Headquarter Overseas Dep MEMO PUBLIC ADDRESS TOTAL SOLUTION ...

Reviews: