Ekars EPA-1200 Operating Manual Download Page 4

SAFETY INTRODUCTION

  3

The following safety instructions have been included in compliance with safety

standard regulations.

1.  Read Instructions

      All the safety and operation instructions should be read before the appliance is 

      operated.

2.  Retain instructions

     The safety and operating instructions should be retained for future reference.

3.  Heed warnings

     All warning on the appliance and in the operation instructions should be

     adhered to.

4.  Follow instructions

     All operating and use instructions should be followed.

5.  Water and Moisture

     The appliance should not be used near water-for example, near a bathtub, washbowl,

      kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc.

6.  Cart and Stands

     The appliance should be used only with a cart or stand that is recommended by

      manufacturer.

7.  Wall and Ceiling Mounting

     The appliance should be mounted to a wall or ceiling only as recommended

      by the manufacturer.

8.  Ventilation

     The appliance should be situated so that its location or position does not

      interfere with its proper ventilation. For example, the appliance should not be

      situated on a bed, sofa, rug or similar surface that may block the ventilation

      openings or placed in a built-in installation, such as a bookcase or cabinet that

      may impede the flow of air through the ventilation openings.

9.  Heat

     The appliance should be situated away from heat sources such as heat radiators,

     stoves, or other appliances(including amplifiers) which produce heat.

10. Power Sources

     The appliance should be connected to a power supply only of the type described

       in the operating instructions or as marked on the appliance. 

Summary of Contents for EPA-1200

Page 1: ...EPA 600 900 1200 Professional Power Amplifier OPERATING MANUAL ...

Page 2: ...1 INTRODUCTION 2 SAFETY INTRODUCTION 3 4 FRONT REAR PANEL DISPLAY 5 FRONT REAR PANEL CONTROL 6 SPEAKER CONNECTIONS 7 BLOCK DIAGRAM 8 SPECIFICATIONS 9 INDEX ...

Page 3: ...tory and tradition are paying hardest efforts to turn out products which can go with consumers taste under continuos R D and Q C based on long accumulated know how We are sure this product will enhance the function of your systems one level higher your further interests in our products and continuous encouragement would be very much appreciated Thank you again ...

Page 4: ... appliance should be used only with a cart or stand that is recommended by manufacturer 7 Wall and Ceiling Mounting The appliance should be mounted to a wall or ceiling only as recommended by the manufacturer 8 Ventilation The appliance should be situated so that its location or position does not interfere with its proper ventilation For example the appliance should not be situated on a bed sofa r...

Page 5: ...nstall a blank ing panel between two amps 14 Cleaning The appliance should be cleaned only as recommended by the Manufacturer 15 Object and Liquid Entry Care should be taken so that object do not fall and liquids are not spilled into the enclosure through openings 16 Power Lines An outdoor antenna should be located away from power lines 17 Damage Requiring Service The appliance should be serviced ...

Page 6: ... EQUIPMENT TO RAIN OR MOISTURE WARNING WARNING TO REDUCE THE RISK OF FIRE TO REDUCE THE RISK OF FIRE REPLACE ONLY WITH SAME TYPE FUSE REPLACE ONLY WITH SAME TYPE FUSE CAUTION CAUTION CAUTION CAUTION RISK OF ELECTRIC SHOCK RISK OF ELECTRIC SHOCK DO NOT OPEN DO NOT OPEN MADE IN KOREA MADE IN KOREA www ekars co kr www ekars co kr 000W STEREO 000W STEREO POWER AMPLIFIER POWER AMPLIFIER OUTPUT POWER 00...

Page 7: ...ate when the signal reaching 1 25Volts 4dBM or more 4 TEMP ERR This indicator operate when the temperature rise to over 95 at heat sink in the main amplifier 5 PROTECT LED This indicator operate when occur a problem over load over heating and DC Voltage 6 POWER SWITCH Pressing this switch to ON will supply the power to this unit 7 SPEAKER JACK Connect same Poles of speaker as terminal of connectio...

Page 8: ...recommended that you use high quality heavy gauge speaker cable with low resistance Designed specially for audio applications using thin cable with high resistance may impair sound quality and prevent the amplifier from delivering its full potential The speaker cables for both channels should be approximately equal in length as a marked difference can result in improper left right balance Speaker ...

Page 9: ...8 BLOCK DIAGRAM ...

Page 10: ...ower 4ohms 1dB rated ouput 4ohms more than 100dB A FILTER more than 100dB A FILTER more than 100dB A FILTER DAMPING FACTOR 8ohms 1KHz more than 150 more than 150 more than 150 less than 0 05 less than 0 05 less than 0 05 less than 0 1 less than 0 1 less than 0 1 1 25V RMS 4dBm 20kohms 1 25V RMS 4dBm 20kohms 1 25V RMS 4dBm 20kohms 10Hz 40KHz 10Hz 40KHz 10Hz 40KHz 20Hz 20KHz 20Hz 20KHz 20Hz 20KHz mo...

Page 11: ...10 MEMO ...

Page 12: ...618 Shihwa Industrial Complex 1378 Jungwang Dong Shiheung City Kyunggi Do Korea 429 450 Tel 82 31 432 5112 82 31 432 4422 Fax 82 31 432 5450 82 31 431 1690 E mail export ekars co kr trade ekars co kr Home Page http www ekars co kr http www samhyoung co kr Headquarter Overseas Dep MEMO PUBLIC ADDRESS TOTAL SOLUTION ...

Reviews: