Rear Panel Controls

5

1.2. DC 24V INPUT TERMINAL

   This is a terminal for connecting to the Unswitched output terminal of   
   Power Distributor (EPS-3173).

3. EMERGENCY CONTROL OUTPUT CONNECTOR

   This is for connecting to the Emergency Control Input connector of Matrix Logic
   (EML-2161).

4. EMERGENCY SWITCHED INPUT CONNECTOR

   This is for connecting to the Output Terminal of Fire Alarm System.

5. EMERGNECY SWITCHED INPUT TERMINAL

   This is for connecting to the Output Terminal of Fire Alarm System.

6. EXTENSION INPUT & 7. EXTENSION OUTPUT CONNECTOR

   You can extend circuits using these Connectors When you need more circuits.

DC INPUT

EM CONTROL OUT

FIRE ALARM IN

18

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

COM

15

13

11

9

7

5

3

1

COM

2

16

14

12

10

8

6

4

EXPANSION

OUT

24V

FIRE
EM

18
17

COM
COM

18
17

FIRE ALARM IN

IN

CTRL-OUT

1~16

CTRL-IN

1~16

MADE  IN  KOREA

MADE  IN  KOREA

PUBLIC ADDRESS

PUBLIC ADDRESS

www.ekars.co.kr

EMERGENCY SWITCHER

EMERGENCY SWITCHER

POWER CONSUMPTION 2W

POWER CONSUMPTION 2W

MODEL NO : EES-2161

MODEL NO : EES-2161

CAUTION

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISK OF ELECTRIC SHOCK

DO NOT OPEN

OF FIRE OR ELECTRIC SHOCK 
DON'T EXPOSE THIS EQUIPMENT
TO RAIN OR MOISTURE.

TO REDUCE THE RISK

WA R N I N G

:

SN

1

2

3

4

5

6

7

Summary of Contents for EES-2161

Page 1: ...EES 2161 Public Address Emergency Switcher OPERATING MANUAL ...

Page 2: ...nel Controls 5 5 Connections 6 1 SamHyoung Electronics Co Ltd 936 4 Kumuncheoun Ri Hyangnam Myun Hwaseong City Kyunggi Do Korea 445 922 Tel 82 31 432 5112 82 31 432 4422 Fax 82 31 352 7637 82 31 352 7649 Home Page http www ekars co kr http www samhyoung co kr E mail export ekars co kr trade ekars co kr ...

Page 3: ... receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure CAUTION Although it is neither complicated to install nor difficult to operate your Emergency Switcher a few minutes of your time is required to read manual for a properly wired installation and becoming familiar with its many features and how to use them Please take a great care in unpacking your Emergen...

Page 4: ...ON To extend over sixteen layers you need the next Emergency Switcher BASEMENT BROADCASTING It is easy to link entire floor of fire alarm from the first basement floor to the sixth basement floor For basement garage 3 Specifications Fire sensor 16 lines Indicator Fire EM 16 lines Power Requirements DC24V Power Consumption 2 Watts Net Weight kg lb 2 8 6 2 Dimensions 483 W x 44 5 H x 250 D mm Specif...

Page 5: ...n you can broadcast by manual 2 EMERGENCY ALL INDICATOR This indicates the ALL switch turns on 3 EMERGENCY SPEAKER SELECTOR On EMERGNECY situation you can broadcast the selected area by manual 4 EMERGENCY SPEAKER INDICATOR These indicate the EMERGENCY switches turn on ...

Page 6: ... can extend circuits using these Connectors When you need more circuits DC INPUT EM CONTROL OUT FIRE ALARM IN 18 1 3 5 7 9 11 13 15 17 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 2 4 6 8 10 12 14 16 COM 15 13 11 9 7 5 3 1 COM 2 16 14 12 10 8 6 4 EXPANSION OUT 24V FIRE EM 18 17 COM COM 18 17 FIRE ALARM IN IN CTRL OUT 1 16 CTRL IN 1 16 MADE IN KOREA MADE IN KOREA PUBLIC ADDRESS PUBLIC ADDRESS www e...

Page 7: ... OUT UNSWITCHED OUT BATTERY 24V DC INPUT SWITCHED 24V DC OUT ONLY AMP SWITCHED 24V DC OUT ONLY AMP SWITCHED OUT 3000W MAX SWITCHED OUT 3000W MAX UNSWITCHED OUT 750W MAX UNSWITCHED OUT 750W MAX 24V 24V TO REDUCE THE RISK OF FIRE TO REDUCE THE RISK OF FIRE REPLACE ONLY WITH SAME TYPE FUSE CAUTION TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DON T EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE WARNING CAU...

Page 8: ...TROL OUT 18 1 3 5 7 9 11 13 15 17 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 2 4 6 8 10 12 14 16 FIRE EM 18 17 CTRL OUT 1 16 ALL LED ALL 1 2 3 4 5 16 ALL COM 15 13 11 9 7 5 3 1 COM 2 16 14 12 10 8 6 4 FIRE ALARM IN 1 2 3 4 5 16 1 2 3 4 5 16 17 18 1 2 3 4 5 16 DC INPUT 24V COM LED ...

Page 9: ...fice 936 4 Kumuncheoun Ri Hyangnam Myun Hwaseong City Kyunggi Do Korea 445 922 Tel 82 31 432 5112 82 31 432 4422 Fax 82 31 352 7637 82 31 352 7649 E mail export ekars co kr trade ekars co kr Home Page http www ekars co kr http www samhyoung co kr Headquarter Overseas Dep MEMO PUBLIC ADDRESS TOTAL SOLUTION ...

Reviews: