General information - To install and use any electric appliance a few fundamental rules must be 
respected.  This  appliance  must  be  installed  by  specialised  personnel  in  accordance  with  the 
regulations in force. Any maintenance or adjustment intervention must be carried out with the 
appliance unplugged from the power source. 

Warning: Gas cooking appliances produce heat and damp in the room where they are located. 
An  adequate  airing  of  the  room  must  be  ensured  by  keeping  every  natural  ventilation  orifice 
open or by installing an inlet hood fitted with a waste pipe.

    

Place  of  installation

Place  of  installation

Place  of  installation

Place  of  installation  -  For  the  gas  appliance  to  work  correctly,  the  gas  combustion  must  be 
supplied  by  enough  air  reaching  the  room  in  a  natural  way.  (The  installer  must  abide  by  the 
current  national  installation  norms  and  subsequent  amendments).  The  air  circulating  into  the 
room must arrive directly from openings made in the external walls. Such openings must have a 
clear  100  cm

2

  cross  section  area  for  the  air  flow  and  a  100  cm

2

  one  to  discharge  combusted 

gas.  Should  other  gas  operating  appliances  be  installed,  such  openings  must  be  appropriately 
enlarged. These openings must be located in such a way as not to be obstructed from either the 
inside or the outside. The opening allowing air circulation must be placed close to the ground, 
whilst  the  one  used  for  the  combustion  discharge  must  be  located  on  the  high  side  of  an 
external  wall.  Could  not  these  openings  be  made  in  the  same  area  where  the  appliance  is 
installed, the amount of air needed could also come from an adjacent room, provided that this 
is not a bedroom nor a dangerous area and that it is appropriately ventilated (current national 
installation norms and subsequent amendments). 

Discharge of combustion products

Discharge of combustion products

Discharge of combustion products

Discharge of combustion products

 - 

Gas type cooking appliances must discharge the combusted 

products  through  hoods  connected  to  the  chimney  flue  or  directly  to  the  outside.  The  hood 
must be positioned at least 700 mm far from the working surface. Keep this distance also when 
installing components or shelves horizontally above the appliance. In case a hood could not be 
installed,  an  electric  ventilation  unit  must  be  applied  to  the  external  part  of  the  room  or  to  a 
window, provided that the room is fitted with openings for air circulation (the current national 
installation norms and subsequent amendments). The electric ventilation unit must ensure an air 
circulation rate equivalent to 3-5 times the volume of that room per hour.

 

Warning: an intense and prolonged use of the appliance may require additional aeration, which 
could be achieved opening a window or increasing the mechanical inlet power, where it exists, 
consequently improving the airing efficiency. 
 

Residual risks

Residual risks

Residual risks

Residual risks 

-

 

Keep away from the appliance unskilled personel. 

-

 

The  appliance  contains  electrical  parts  and  must  never  be  washed  with  a  jet  of  water  or 
steam. 

-

 

To avoid wrong installation, the right gas connection is showed on a label that identifies the 
correct gas type to use. 

-

 

The appliance is electrically connected: before attempting any cleaning operation, cut power 
to the appliance. 

-

 

The  removable  parts  of  the  cooking  top,  after  the  cleaning  operation,  must  be  placed 
correctly  in  their  housing  in  order  to  avoid  anomalous  and  dangerous  functioning  of  the 
burners. 

4. 

4. 

4. 

4. Gas connection

Gas connection

Gas connection

Gas connection    

Connect  the  appliance  to  a  gas  cylinder  or  mains  gas  pipe  according  to  the  prescriptions  of 
standards (as per current national installation norms and subsequent amendments). To connect 
gas,  use  an  approved  rigid  metal  pipe  in  copper  or  stainless-steel  (the  current  national 
installation  norms  and  subsequent  amendments).  The  appliance  is  equipped  with  threaded  GJ 

Summary of Contents for EKP96

Page 1: ...l S r l S r l Via Via Via Via Marco Polo Marco Polo Marco Polo Marco Polo n 1 n 1 n 1 n 11 1 1 1 3501 3501 3501 35010 0 0 0 Borgoricco Borgoricco Borgoricco Borgoricco Padova Italy Padova Italy Padova Italy Padova Italy Tel 39 049 9300344 Tel 39 049 9300344 Tel 39 049 9300344 Tel 39 049 9300344 39 049 5791479 Fa 39 049 5791479 Fa 39 049 5791479 Fa 39 049 5791479 Fax 39 049 5794387 x 39 049 5794387...

Page 2: ...ive 2006 95 EC Electromagnetic compatibility Directive 2004 108 EC TECNOEKA Srl declares that the above mentioned products are in compliance with the following harmonized standards CEI EN 60335 1 CEI EN 60335 2 6 CEI EN 55014 1 CEI EN 61000 3 2 CEI EN 61000 3 3 TECNOEKA Srl declares that the above mentioned products are in compliance with the following directives Gas Appliances directive 2009 142 ...

Page 3: ... Adapting cook Adapting cook Adapting cook top to different types of gas top to different types of gas top to different types of gas top to different types of gas 7 7 7 7 Instructions for use Instructions for use Instructions for use Instructions for use 8 8 8 8 Cleaning and maintenance Cleaning and maintenance Cleaning and maintenance Cleaning and maintenance 9 9 9 9 Technical assistance and orig...

Page 4: ...rms and subsequent amendments so that an appropriate quantity of air is supplied for the gas combustion setting and for ventilating the room The appliance must discharge the products of combustion into an appropriate hood connected to a chimney flue or directly to outside the building If a hood cannot be installed an electric fan installed on a window or on a wall facing outside is permitted This ...

Page 5: ...hnical specifications Technical specifications Model Model Model Model EKP 96 EKP 96 EKP 96 EKP 96 EKTP 96 EKTP 96 EKTP 96 EKTP 96 EKTP 96 001 EKTP 96 001 EKTP 96 001 EKTP 96 001 Overall dimensions LxDxH mm 900x600x280 900x600x850 Power supply voltage V 230 Frequency Hz 50 Class I Nominal thermal capacity kW 14 25 Appliance category for United Kingdom II2H3 Gas connection Installation class Class ...

Page 6: ...ventilated current national installation norms and subsequent amendments Discharge of combustion products Discharge of combustion products Discharge of combustion products Discharge of combustion products Gas type cooking appliances must discharge the combusted products through hoods connected to the chimney flue or directly to the outside The hood must be positioned at least 700 mm far from the w...

Page 7: ...not be interrupted by the switch earth cable must not be interrupted by the switch I I I If the supply cable is damaged then it must be repla f the supply cable is damaged then it must be repla f the supply cable is damaged then it must be repla f the supply cable is damaged then it must be replaced by the manufacturer or by your ced by the manufacturer or by your ced by the manufacturer or by you...

Page 8: ... h g h g h g h G31 G31 G31 G31 37mbar 37mbar 37mbar 37mbar g h g h g h g h G20 G20 G20 G20 20mbar 20mbar 20mbar 20mbar l h l h l h l h Triple crown Triple crown Triple crown Triple crown burner Nr burner Nr burner Nr burner Nr 1 1 1 1 3 3 3 3 5 5 5 5 1 1 1 1 8 8 8 8 95 95 95 95 135 135 135 135 74 74 74 74 Regul Regul Regul Regul 255 255 255 255 250 250 250 250 334 334 334 334 Fast burner Fast burn...

Page 9: ...ing the protecting enamal in irreparable way 8 8 8 8 Cleaning and maintenance Cleaning and maintenance Cleaning and maintenance Cleaning and maintenance ATTENTION Before any operation disconnect the electric supply ATTENTION Before any operation disconnect the electric supply ATTENTION Before any operation disconnect the electric supply ATTENTION Before any operation disconnect the electric supply...

Page 10: ...lation maintenance or anything else specified in our sales conditions or anything else specified in our sales conditions or anything else specified in our sales conditions or anything else specified in our sales conditions 9 9 9 9 Technical assistance and original spare parts Technical assistance and original spare parts Technical assistance and original spare parts Technical assistance and origin...

Page 11: ...78700 Cock with valve for 3500 W burner triple crown 01991608700 11 11 11 11 Informations to the consumers Informations to the consumers Informations to the consumers Informations to the consumers Further to Directive 2002 96 EC the symbol of the crossed rubbish skip on the appliance means that at the end of its life the product must be disposed of separately from the other rubbish The user must h...

Page 12: ...adjustments and or maintenance and or repairs carried out by unauthorised personnel and or with non original spare parts 8 inadequate or careless maintenance of the product in contrast with the user s handbook supplied with the product 9 damages caused by fire natural disasters and accident as well as by any cause not attributable to TECNOEKA SRL The warranty explicitly excludes The warranty expli...

Reviews: