EIPL BD75P Owner'S Manual Download Page 9

 

 

 

 

Page 9 of 12 

Drawing   : - TPC476 
Issue 

: - 2 

Date 

: - 11/04/19 

    

WARNINGS

  

 

 

This appliance can be used by children from 8 years and above and persons 

with reduced physical, sensory or mental capabilities or lack of experience 

and knowledge if they have been given supervision or instruction concerning 

use of the application in a safe way and understand the hazards involved. 

 

Children shall not play with the appliance. 

 

Cleaning and user maintenance shall not be made by children without 

supervision. 

 

If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, 

its service agent or similarly qualified person in order to avoid hazard. 

 

This product contains fluorinated greenhouse gases covered by the Kyoto 

Protocol. The refrigeration system is hermetically sealed. 

 

The Global Warming Potential (GWP) of refrigerants used in products 

manufactured by Ebac Industrial Products Ltd is as follows 

R134a – 1300 

R407c – 1610 

 

For type and weight of refrigerant contained in this unit, please refer to the 

product data label 

 

Due to the high pressures within the refrigeration circuit, under no 

circumstances must direct heat be applied to the evaporator coil in an attempt 

to remove the build-up of ice. 

 

No attempt should be made to cut open any part of the refrigeration circuit 

due to high pressures and gas involved. 

 

If the unit is switched off at the mains power supply for any reason, the unit 

must be allowed to stand at rest for at least three minutes before restarting. 

 

For correct installation and operation the unit inlet and outlet must have a 

clearance of 0.5M from all adjacent surfaces and or structures.

Summary of Contents for BD75P

Page 1: ...Page 1 of 12 Drawing TPC476 Issue 2 Date 11 04 19 BD75P INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Page 2: ...phase plus the additional heat generated by the compressor The air is therefore discharged from the dehumidifier at a slightly higher temperature with a lower absolute humidity than that which entered...

Page 3: ...al GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the p...

Page 4: ...e the evaporator coils through the rear grille to confirm frost formation or weeping If the air temperature is below 25 C an even coating of frost should cover the entire evaporator coil If the air te...

Page 5: ...ng accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiring connections including mains cable for damage or loose connections 5 In order t...

Page 6: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Page 7: ...fault 3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass va...

Page 8: ...019712 1 5 Capillary 3014251 1 64ft 6 Solenoid valve 3020836 1 7 Filter dryer 3020937 1 8 Solenoid coil 3030452 1 9 On Off switch 3035914 1 10 Fan Motor 3947013 1 11 Fan Blade 3947014 1 12 Castor 3050...

Page 9: ...to Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407...

Page 10: ...Page 10 of 12 Drawing TPC476 Issue 2 Date 11 04 19...

Page 11: ...Page 11 of 12 Drawing TPC476 Issue 2 Date 11 04 19...

Page 12: ...ww eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www eba...

Reviews: