background image

Page 6 of 12 

Drawing   : - TPC447 
Issue 

: - 2 

Date 

: - 23/05/16 

OPERATION 

The  following  procedures  should  be  followed  to  test  the  CS90E  for  correct 
operation: 

1.

After  unpacking,  examine  all  external  features  to  confirm  damage-
free shipment. Report all defects and damage at once.  Connect the
power cable to a grounded 15 Amp electrical outlet.

2.

Setting the humidistat

Turn fully clockwise

3.

Check dehumidification process as follows:

A.

Place unit on a level surface.

B.

Start up unit by turning the ON/OFF switch to ON

C.

Check that the compressor is running.

D.

Leave the machine running for 15 minutes.

E. Observe  the  evaporator  coils  through  the  rear  upper  grill,  to

confirm frost operation.

i.

If the air temperature is below 80° F, an even coating of

frost should cover the entire evaporator coil 

ii. If the air temperature is above 80° F, frost and/or droplets

of  condensed  water  should  cover  the  entire 
evaporator coil.  

F.

After  continuous  running  time  of  approximately  55  minutes,  the
unit  will  enter  “Hot  Gas”  defrost  mode  for  5  minutes  and  then
automatically return to normal operation.

If, after carrying out the above procedures, the unit does not appear to 
function properly, refer to the 

Trouble Shooting

 section, which follows, 

or contact the Factory Service Center. 

TO ENSURE CONTINUED FULL EFFICIENCY OF THE 

DEHUMIDIFEIR, MAINTENANCE PROCEDURES SHOULD BE 

PERFORMED AS FOLLOWS: 

CAUTION: 

ONCE THE UNIT HAS BEEN SWITCHED OFF, WAIT AT 

LEAST FIVE MINUTES BEFORE RESTARTING. 

E B A C   C S - 9 0 - E    D E H U M I D I F I E R     O W N E R ' S    M A N U A L 

Pure n Natural Systems  |  purennatural.com  |  1-800-237-9199

Summary of Contents for EBAC CS90

Page 1: ...f 12 Drawing TPC447 Issue 2 Date 23 05 16 CS90E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL E B A C C S 9 0 E D E H U M I D I F I E R O W N E R S M A N U A L Pure n Natural Systems purennatural com 1 800 2...

Page 2: ...ONTENTS Item Description Quantity 10590GE US Dehumidifier 1 3944110 PVC tube 3 8 I D 7 8 M 3086144 Quick release hose coupling 1 TPC447 Manual 1 E B A C C S 9 0 E D E H U M I D I F I E R O W N E R S M...

Page 3: ...ehumidifier at a slightly higher temperature with a lower absolute humidity than that which entered Continuous circulation of air through the dehumidifier gradually reduces the relative humidity withi...

Page 4: ...e hot gas defrost system controlled by an electronic timer guarantees positive de icing thereby optimizing operation at low temperatures The unit incorporates a welded and galvanized steel chassis and...

Page 5: ...strial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label MODEL CS90E HEIGHT 15 2 386mm WIDTH 14 353mm DE...

Page 6: ...r temperature is below 80 F an even coating of frost should cover the entire evaporator coil ii If the air temperature is above 80 F frost and or droplets of condensed water should cover the entire ev...

Page 7: ...an frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiring connections 5 In order to check the defrost operation t...

Page 8: ...d and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing further loss of refrigerant gas 3 The refrigerant compressor...

Page 9: ...the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1 Contact the Factory Service Center 2 Contact the Factory Ser...

Page 10: ...01 1 6 Capillary Tube 3014249 2 x 30 7 Drain Tubing 3014338 9 Feet 8 Solenoid Valve 3020837 1 9 Filter Dryer 3020901 1 10 Compressor 3022198 1 11 Solenoid Coil 3030451 1 12 Capacitor 3030908 1 13 Main...

Page 11: ...SCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS SECTION FOR YOUR RECORDS CLIP AND RETURN THIS CARD PLEASE NOTE WARRANT...

Page 12: ...ssue 2 Date 23 05 16 E B A C C S 9 0 E D E H U M I D I F I E R O W N E R S M A N U A L Pure n Natural Systems purennatural com 1 800 237 9199 Distributed by Pure n Natural Systems Inc Streamwood IL pu...