background image

 

 

 

 

Page 9 of 12 

Drawing   : - TPC508 
Issue 

: - 1 

Date 

: - 29/01/20 

CD35S 

SPARE PARTS LIST

 

 

Part Number  Description 

1137907 

WATER CONTAINER 

2013865 

MICROSWITCH SUPPORT 

2013866 

MICROSWITCH LEVER 

2017707 

HUMIDEX 7 KNOB 

2131107 

HUMIDEX DRAIN TRAY 

2139528 

REFRIGERATION COIL SET 

3014253 

CAPILLIARY TUBE 

3020811 

BY-PASS VALVE 

3020937 

FILTER DRYER 

3033033 

MICROSWITCH 

3035145 

HUMIDISTAT 

3035346 

PANEL MOUNTED TERMINAL BLOCK 

3036636 

RED LAMP ASSY 

3040129 

FAN BLADE 

3050216 

CASTOR 

1619519 

PCB 

2141095 

MAINS POWER CABLE 

3944958 

COMPRESSOR 

3030421 

SOLENOID COIL 

3035773 

MOTOR 

2013837 

DRAIN TRAY 

 
 

Spare parts available online 

 

www.EIPLDIRECT.com 

Summary of Contents for CD35S

Page 1: ...Page 1 of 12 Drawing TPC508 Issue 1 Date 29 01 20 CD35S INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Page 2: ...Page 2 of 12 Drawing TPC508 Issue 1 Date 29 01 20 CD35S PACKAGE CONTENTS Item Description Quantity 10186SG US Dehumidifier 1 TPC508 Manual 1...

Page 3: ...ermanent drain The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase plus the additional heat generated by the compresso...

Page 4: ...sed in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label MODEL...

Page 5: ...ater container disconnect the power supply and allow the dryer to stand for five minutes Remove the container from the rear of the unit and when emptied replace taking care to ensure that the float me...

Page 6: ...tor shaft and that the fan rotates freely 3 To check the refrigerant charge run the unit for 15 minutes and briefly remove the cover The evaporator coil should be evenly frost coated across its surfac...

Page 7: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Page 8: ...the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center 4 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1 Cont...

Page 9: ...UMIDEX DRAIN TRAY 2139528 REFRIGERATION COIL SET 3014253 CAPILLIARY TUBE 3020811 BY PASS VALVE 3020937 FILTER DRYER 3033033 MICROSWITCH 3035145 HUMIDISTAT 3035346 PANEL MOUNTED TERMINAL BLOCK 3036636...

Page 10: ...WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS SECTION F...

Page 11: ...oto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R40...

Page 12: ...ww eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www eba...