Summary of Contents for CD30SE

Page 1: ...Page 1 of 12 Drawing TPC500 Issue 1 Date 29 01 20 CD30SE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Page 2: ...1 Date 29 01 20 CD30SE PACKAGE CONTENTS Item Description Quantity 1142050 Dehumidifier 1 1139504 Wall mount bracket 1 3082214 Brass wood screw 3 3088525 Rawl plug 3 3014338 PVC tube 12mm I D 3 M 30861...

Page 3: ...point Moisture forms on the evaporator coil and is collected in the condensate tray which is equipped with a permanent drain The cooled air then passes through the hot condenser coil where it is rehe...

Page 4: ...he Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this u...

Page 5: ...the maximum setting c Check the compressor is running d Leave the machine running for 15 minutes e Observe the evaporator coils to confirm frost formation i If the air temperature is below 70 F an eve...

Page 6: ...distat which has been factory pre set at 70 RH allows for connection to an external warning system This warning indicating system will be monitored by the customer and will warn and indicate when the...

Page 7: ...e 25 C the coil may be covered with droplets of water rather than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all...

Page 8: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Page 9: ...oss of refrigerant gas 4 Blocked filter dryer 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center 4 Contact the Factory Service Center Little or no defro...

Page 10: ...MBER Compressor 1 3944958 Refrigeration Coil Set 1 3020740 Evaporator Coil 1 2139528 Fan Motor 1 3035773 Fan Blade 1 3040129 Timer Board 1 1619519 Humidistat 1 3035145 Humidistat Knob 1 3030421 Soleno...

Page 11: ...oto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R40...

Page 12: ...ww eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www eba...