13
9.2 Connecting consumers to the generator
Connect the machine you want to use to the
230V~ sockets (3).
Important:
This sockets together may be loaded
continuously (S1) with 2000W and temporarily
(S2) for a maximum of 5 minutes with 2200W.
The generator is suitable for 230 V~ a.c.
appliances.
Do not connect the generator to the household
network as this may result in damage to the gene
rator itself or to other electrical appliances in your
home.
Note: Some electrical appliances (power jigsaws,
drills, etc.) may have a higher level of power con-
sumption when used in difficult conditions.
9.3 Switching off the engine
Before you switch off the generator, allow it to run
briefly with no consumers so that it can "cool
down”
Move the ON/OFF switch (10) to position "OFF”
with the key.
Close the petrol cock
Important! The generator is fitted with an
overload cut-out.
This shuts down the sockets (3). You can restart the
sockets (3) by pressing the overload
cut-out (5).
Important! If this happens, reduce the electric
power you are taking from the generator.
9.4 Connecting to earth (Fig. 3)
The generator must be earthed to prevent an electric
shock from electrical equipment. To do this, connect
one end of a cable (min. 4 mm
2
) to the earth connec-
tion on the generator (Fig. 4) and the other end to an
external earth (for example an earthing rod).
10. Maintenance
Remove dust and dirt from the machine at regular
intervals. The best tools for cleaning are a fine
brush or a cloth
Do not use any caustic substances to clean the
plastic
Take the petrol mixture out of the generator if you
do not intend to use the generator for a lengthy
period of time
Important: Switch off the machine immediately
and contact your service station:
In the event of unusual vibrations or noise
If the engine appears to be overloaded or misfires
11. TECHNICAL DATA
Generator Synchronous
Protection type:
IP 23
Continuous power S1:
2000 W
Maximum power S2 5 min.:
2200 W
Rated voltage:
2x230 V
쓒
Rated current:
9 A
Frequency: 50
Hz
Drive engine design
4-stroke, air-cooled
Displacement 196
cm
3
Max. power:
4,77 kW / 6,5 PS
Fuel:
normal unleaded petrol
Tank capacity:
15,0 l
Weight: 40
kg
Sound power level LWA: 95
dB(A)
Sound pressure level LpA: 74
dB(A)
Spark plug:
F6 TC
Operating mode S1 (continuous operation)
The machine can be continuously operated with the
quoted power output.
Operating mode S2 (temporary operation)
The machine may be temporarily operated with the
quoted power output (5 min). Afterwards the machine
must be stopped for a while to prevent it from
overheating (5 min).
12. Changing the oil and checking the
oil level (before using the machine)
The engine oil is best changed when the engine is at
working temperature.
Only use engine oil (15W40).
Place the generator on a slightly inclined surface
so that the oil drain plug is at the lower end.
Open the oil filler plug.
Open the oil drain plug and let the hot engine oil
drain out into a drip tray.
After the old oil has drained out, close the oil drain
GB