3. Items supplied
n
Open the packaging and take out the equipment
with care.
n
Remove the packaging material and any
packaging and/or transportation braces (if
available).
n
Check to see if all items are supplied.
n
Inspect the equipment and accessories for
transport damage.
n
If possible, please keep the packaging until the
end of the guarantee period.
IMPORTANT
The equipment and packaging material are not
toys. Do not let children play with plastic bags,
foils or small parts. There is a danger of
swallowing or suffocating!
n
Automatic Domestic Water System
n
Wrench for coarse filter screw
n
Original operating instructions
4. Proper use
Applications
n
Irrigation and watering of green areas, vegetable
beds and gardens.
n
Operation of lawn sprinklers.
n
For drawing water from ponds, streams, rainwater
butts, rainwater cisterns and springs
n
For supplying service water
Transport media:
n
For the pumping of clear water (fresh water),
rainwater or light suds/service water.
n
The maximum temperature of the fluid must not
35°C if the equipment is operated
permanently.
n
Do not use the equipment to pump inflammable,
gassing or explosive fluids.
n
The pumping of aggressive liquids (acids, alkalis,
silo seepage etc.) as well as liquids with abrasive
substances (sand) must likewise be avoided.
n
This equipment is not designed to convey
drinking water.
The equipment is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the manufacturer
will be liable for any damage or injuries of any kind
caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
5. Technical data
Mains supply:
230V ~ 50 Hz
Power rating:
1100 W
Delivery rate max.
3600 l/h
Delivery height max.
46 m
Delivery pressure max.
0,46 MPa (4,6 bar)
Suction height max.
7 m
Pressure connection:
approx. 33.3 mm (R1 female thread)
Suction connection:
approx. 42 mm (R11/4 male thread)
Water temperature max.
35°C
Protection type
IP44
6. Electrical connections
n
Connect the power cable to a 230 V ~ 50 Hz
earthed, 10 amp fuse minimum.
n
The appliance is switched on and off using the
integrated ON/OFF switch.
n
The motor is protected against overloading or
blocking by an integrated thermostat. In the event
of overheating, the thermostat switches off the
pump automatically. The pump will start up again
automatically after it has cooled down.
7. Fitting a suction pipe
n
Screw an intake hose (min. 19 mm (3/4“ ) plastic
hose with spiral reinforcement) either directly or
with a threaded nipple to the pumpʼs intake
connection (42 mm (1 1/4 AG)) (see Fig. 1).
n
The intake hose should rise from the water pick-
up point to the pump. Always avoid laying the
intake line higher than the pump. Air bubbles in
the intake line delay and hinder suction.
n
The intake and pressure lines must be attached in
such a way that they do not place the pump under
any mechanical strain.
10