GB
9
앬
The equipment is not designed for installation in
laundries.
앬
The equipment must be positioned in such a way
that the mains plug is accessible at all times.
앬
The temperature in the cooling circuit may
become very hot. For this reason keep all cables
away from the copper lines.
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
Packaging:
The unit is supplied in packaging to prevent it from
being damaged in transit. The raw materials in this
packaging can be reused or recycled.
Tips on saving energy
Only use the air conditioner when you really need to.
Do not select too high a temperature for heating or
too low a temperature for cooling. Select the “Sleep”
function during the night.
Close all windows, doors and Venetian blinds in
order to reduce incoming sunlight as far as possible.
Principle of operation for cooling
Heat is extracted from the air in the room by the air
heat-exchanger (evaporator) in which the coolant
circulates. This air is conveyed to the outside air
heat-exchanger (condenser).
This gives off heat to the outdoor air. Electrical
energy is required for this. In certain circumstances
condensation may form on the evaporator on the
indoor unit, which will be removed by the
condensation hose.
Principle of operation for heating
In heating mode, heat is removed from the outdoor
air by the outdoor device and fed into the indoor
device. This passes the heat on to the room which it
is to heat. Electrical energy is required for this. In
certain circumstances condensation may be
produced on the outdoor device, which must be
discharged via the condensation drain on the
underside of the outdoor device.
2. Items supplied
1 indoor device I1 (box 1, art. no. 23.654.26)
1 indoor device I2 (box 2, art. no. 23.654.27)
1 outdoor device (box 3, art. no. 23.654.28)
1 set of installation accessories (for details,
see page 15)
3. Technical data
Cooling capacity
2 x 2500 watts
Heating capacity
2 x 2900 watts
Energy efficiency
C (EER 2.81/COP 3.02)
Air capacity
2 x 420 m
3
/h
Absorbed humidity (30°C/80% RH)
2 x 1.0 l/h
Timer 24
h
Operating voltage
230 V ~ 50 Hz
Socket fusing
16 A
Nominal power consumption, cooling
2 x 890 watts
Nominal current consumption, cooling
2 x 4.0 A
Nominal power consumption, heating
2 x 950 watts
Nominal current consumption, heating
2 x 3.9 A
Compressor Rotary
piston
Compressor starting current
28 A
Outdoor temperature cooling max.
+43°C
Outdoor temperature heating
+7 - + 24°C
Fluid line Ø A
6.35 mm
Suction pipe Ø A
9.53 mm
Length of refrigerant line supplied
5 m
Length of refrigerant line, max.
10 m
Max. difference in height between indoor/outdoor
device
5 m
Refrigerant
R 410 A
Refrigerant filling capacity
2 x 800 g
Refrigerant refill quantity from 5 m
15 g/m
Sound pressure level
Inside
≤ 38 dB (A)
Outside
≤ 56 dB (A)
Dimensions
Inside
79 x 27,5 x 20 cm
Outside
85 x 29 x 61 cm
Weight
Inside 8
kg
Outside 52
kg
Note:
The specified capacities and performances are
based on the following conditions (EN 14511):
Anleitung_Dual_Split_2500_C_H_GB:_ 24.01.2008 8:17 Uhr Seite 9
Summary of Contents for DUAL SPLIT 2500 C+H
Page 3: ...3 5 4 6 8 7 9 4 5 A B C E D 11 Anleitung_Dual_Split_2500_C_H_GB _ 24 01 2008 8 17 Uhr Seite 3 ...
Page 5: ...5 17 16 18 19 20 A B Anleitung_Dual_Split_2500_C_H_GB _ 24 01 2008 8 17 Uhr Seite 5 ...
Page 22: ...22 Anleitung_Dual_Split_2500_C_H_GB _ 24 01 2008 8 17 Uhr Seite 22 ...
Page 23: ...23 Anleitung_Dual_Split_2500_C_H_GB _ 24 01 2008 8 17 Uhr Seite 23 ...